Three Phase Power Factor Capacitor

China Three Phase Power Factor Capacitor, Find details about China Three Phase Power Capacitor, Power Factor Capacitor from Three Phase Power Factor Capacitor

Model NO.
BSMJ
Electrolyte
Electric Heating
Usage
Power Factor Capacitor
Voltage
220VAC~690VAC
Trademark
CSF
Specification
IEC60831
Origin
China
HS Code
85322590
Model NO.
BSMJ
Electrolyte
Electric Heating
Usage
Power Factor Capacitor
Voltage
220VAC~690VAC
Trademark
CSF
Specification
IEC60831
Origin
China
HS Code
85322590
Three Phase Power Factor Capacitor

Air conditioner capacitor,oil capacitor, motor capacitor,IGBT capacitor,CBB65 capacitor,motor run capacitor,aluminum case capacitor,anti-explosion capacitor  ,inverter welding capacitor, fan capacitor, CBB61 capacitor.
1. Apply standard: GB/T12747.1-2004 IEC60831-1: 1996
2. Apply condition: Indoor, -25° C~40° C, humidity: <=80%RH, height<=2000MSL
3. Rated voltage: 230VAC. 250VAC. 400VAC. 415VAC. 440VAC, 450VAC. 525VAC. 690VAC
4. Rated output: 1~60kvar
5. Capacitance tolence: 0~10%
6. Voltage endurance: 2Un 10 seconds between T-T, 3000VAC 10 seconds between T-C.
7. Loss angle tangent: Less than 0.1%(rated voltage at 20° C).
8. Ceiling voltage: 1.1Un(root mean square value )
9. Ceiling current: 1.3In(root mean square value )
10. Self-discharge feature: The terminal voltage will reduce below 50V in 3 minutes after disconnecting from power line.
Specifications can be supplied according to the customers' special need.
Reasonable price and stable quality.
Three Phase Power Factor Capacitor

 

Series Three Phase Power Factor Capacitor
   
Rated Voltage Range From 220-1000 VAC
Connection 3 phase (1 phase on request)
Frequency 50/60 Hz.
PowerRange 1-100 Kvar
Dielectric Metalized polyprolilene film
Protection IP 42 (IP 54 on request)
Discharge Resistors Built in automatic discharge resistors included, less than 75V within 3 minutes after de-energizing the capacitor
Tolerance ± 5%
Maximum Ambient Temperature   -25 º C--50º C  (Other temperature range on request)
  Average temperature within 24 hours below 40º C& average
  temperature with a year below 30º C
Max. Relative Humidity ≤ 90%   
Max. Altitude ≤ 2000m (Other altitude on request
Over Voltage Tolerance 1.1    UN  (8 hours max. in every 24 hours)
1.15 UN  (30 minutes in every 24 hours)
1.2 UN  (5 minutes in every 24 hours)
1.3 UN  (1 minutes in every 24 hours)
Over Current  Tolerance 30% permanently
Max. Surge Current 200 times of rated current
Dielectric Loss ≤ 0.2 Watt / Kvar
Voltage Test Between terminals: 2.15 Un for 10 seconds.
Between terminals to container:   3000VAC for 10 seconds
Safety System Self protection device
Case Material Rust-proof tinplate
Execution Indoor, minimum distance between units  : 50mm
   
Standard IEC60831 / GBT12747