Titanium Float for Magnetic Float Level Indicator

China Titanium Float for Magnetic Float Level Indicator, Find details about China Magnetic Level Gauge, Titanium Float from Titanium Float for Magnetic Float Level Indicator

Model NO.
float
Warranty
3 Year
Certification
CE, RoHS
Material
SS360L
Process Temperature
-40~250℃
Name
Glass Plate Level Indicator
Temperature
-196° to 400° C
Pressure
1 MPa to 16 MPa
Trademark
dd
Transport Package
Wooden Case
Specification
customized
Origin
Dandong
HS Code
9026100000
Model NO.
float
Warranty
3 Year
Certification
CE, RoHS
Material
SS360L
Process Temperature
-40~250℃
Name
Glass Plate Level Indicator
Temperature
-196° to 400° C
Pressure
1 MPa to 16 MPa
Trademark
dd
Transport Package
Wooden Case
Specification
customized
Origin
Dandong
HS Code
9026100000

316L SS stainless float for magnetic level gauge

 
Titanium Float for Magnetic Float Level Indicator
Titanium Float for Magnetic Float Level Indicator
Titanium Float for Magnetic Float Level Indicator


PTFE coated float
Titanium Float for Magnetic Float Level Indicator

 titanium float

Titanium Float for Magnetic Float Level Indicator
Titanium Float for Magnetic Float Level Indicator

UHC series magnetic float level transmitter and UQC series magnetic ball float level transmitter are new designed generation level indicator according to magnetic coupling principle. They present the level indication directly and clearly with advanced technology and the proper structure and are suitable for petroleum, chemical, power, light industry and pharmaceutical industrial field, etc. UHC series magnetic float level transmitter is mounted on side of vessels, while UQC series magnetic ball float level transmitter is mounted on the top of vessels, especially for the measurement of the underground storage tanks.



 
Titanium Float for Magnetic Float Level Indicator
Titanium Float for Magnetic Float Level Indicator

 

UHC, UQC Series Magnetic Float Level Transmitter

 

Main technical parameter

1.  Local indicator unit
1.1 UHC ordinary magnetic float level transmitter
Application range: This level transmitter is the most frequently used side-mounted magnetic float level transmitter, is suitable for level measuring which the liquid medium PN ≤ 6.3MPa and the operating temperature ≤ 300ºC.
Range: 300mm ~ 6000mm (increasing the range can be manufactured specially)
Nominal pressure: 10MPa ~ 16MPa
Nominal diameter: DN25 (or on request)
Ambient temperature: -40ºC ~ +80ºC
Operating temperature: ≤300ºC
Measuring accuracy: ±5mm
Medium density: Level: ρ≥0.45g/cm³; Interface: ρ1-ρ2 ≥0.16g/cm³
Wetted material: 304, 316L or on request
Flange standard: HG/T20592-2009, HG/T20615-2009 or on request

1.2 UHC.GY high pressure magnetic float level transmitter
Application range: this level transmitter is frequently used in high pressure environment, is suitable for level measuring which the liquid medium PN between 10MPa and 16MPa and the operating temperature ≤ 300ºC.
Range: 300mm ~ 6000mm (increasing the range can be manufactured specially)
Nominal pressure: 10MPa ~ 16MPa
Nominal diameter: DN25 (on request)
Ambient temperature: -40ºC ~ +80ºC
Operating temperature: ≤300ºC
Measuring accuracy: ±5mm
Medium density: Level: ρ≥0.5g/cm³; Interface: ρ1-ρ2 ≥0.16g/cm³
Wetted material: 304, 316L or on request
Flange standard: HG/T20592-2009, HG/T20615-2009 or on request

1.3 UHC.GW high temperature magnetic float level transmitter
Application range: this level transmitter is frequently used in high temperature environment, is suitable for level measuring which the liquid medium of PN ≤ 11MPa and the operating temperature between +300ºC ~ +450ºC.
Range: 300mm ~ 6000mm (increasing the range can be manufactured specially)
Nominal pressure: ≤11.0MPa
Nominal diameter: DN25 (on request)
Ambient temperature: -40ºC ~ +80ºC
Operating temperature: +300ºC ~ +450ºC
Measuring accuracy: ±5mm
Medium density: Level: ρ≥0.5g/cm³; Interface: ρ1-ρ2 ≥0.16g/cm³


 
Titanium Float for Magnetic Float Level Indicator
Titanium Float for Magnetic Float Level Indicator
ModelCodeCode meaning
UHC- Magnetic float level transmitter
UHC.GY- High pressure magnetic float level transmitter
UHC.GW- High temperature magnetic float level transmitter
UHC.F- Antirot magnetic float level transmitter
UHC.O- Vacuum jacket magnetic float level transmitter
UQC- Magnetic ball float level transmitter
 M With local indicator
N Without local indicator
 S With reed-resistance remote level transmitter
U With magnetostrictive remote level transmitter
T Without remote level transmitter
 A With upper or lower limit alarm
C With upper and lower limit alarms
D Without alarm
 E PN1.0MPa
F PN1.6MPa
G PN2.5MPa
J PN4.0MPa
 H PN6.3MPa
 O PN10MPa
 P PN16MPa
 Q Other pressure class
 * Level ρ or interface ρ1 /ρ2
 -  
 * Measuring range.
For UQC, please note the neck length.
 d  Explosion isolation
i Intrinsically safe
 Additional codeW With steam jacket (ZG1/2" male thread)
  L1Vent valve above
  L2Blow-down valve below
  L3Vent valve above and blow-down valve below
            
 

Order requirements

Please select product model according to the model selection table.
   Medium name and density
   Medium operating pressure & temperature
   Wetted material
   Range
   Flange standard