1000V Nyy-J N2xry Yjv32 VV32 Swa Sta Armoured Power Cable XLPE Cable

China 1000V Nyy-J N2xry Yjv32 VV32 Swa Sta Armoured Power Cable XLPE Cable, Find details about China Wire, Electric Wire from 1000V Nyy-J N2xry Yjv32 VV32 Swa Sta Armoured Power Cable XLPE Cable

Model NO.
YJV32 YJV22
Wire Core Material
Annealed Soft Copper
Certification
ISO, CE, RoHS, UL, VDE
Model
Yjv32 Yjv22
Brand
Qifan
Standard
IEC 60502-1 BS 5467 VDE 0276
Staff
3048
QC
206
Trademark
Qifan
Transport Package
Drum
Specification
1.5-800mm2
Origin
China
HS Code
8544492100
Model NO.
YJV32 YJV22
Wire Core Material
Annealed Soft Copper
Certification
ISO, CE, RoHS, UL, VDE
Model
Yjv32 Yjv22
Brand
Qifan
Standard
IEC 60502-1 BS 5467 VDE 0276
Staff
3048
QC
206
Trademark
Qifan
Transport Package
Drum
Specification
1.5-800mm2
Origin
China
HS Code
8544492100
1000V NYY-J N2XRY YJV32 VV32 SWA STA Armoured Power Cable XLPE Cable
0.6/1kV NYY N2XY VV32 YJV32 SWA Armoured  Power Cable XLPE Cable


Cable Selection

It is essential that the type of cable ordered is suitable for its intended use. Cable choice will be based on a whole range of factors including installation specifications, relevant local regulations and the performance of appropriate cable types. It is therefore impossible to provide a conclusive guide to cable selection and we would advise you to contact us for our specialist advice on suitable designs to meet you specific cable needs.

Cable structure

Conductors

Conductors shall be of Copper or Aluminium, circular standed(Non-compacted or Compacted) or Shaped, Class 1 or Class 2 to IEC 60228, BS EN 60228. For smaller sizes, a solid circular conductor, Class 1 as per IEC 60228, BS EN 60228 can also be supplied upon request.

Insulation

XLPE material and thickness shall be as per IEC 60502-1 or BS 5467 rated for 90° C continuous operation.

PVC material and thickness shall be as per IEC 60502-1 or BS 6346. PVC insulation Material-PVC/A as per IEC 60502 or TI1 as per BS EN 50363.

PVC insulation as per SASO 1694 rated for 85° C continuous operation is also available on request.

Assembly

Two, Three Four or Five insulated conductors are laid-up together with non-hygroscopic fillers compatible with the insulation material.

Inner sheath
The assembly is bedded with an extruded layer of PVC. In case of non-armoured cables, this layer may be omitted if the outer shape of the cable remains practically circular.

Armour

Galvanized Steel Wires applied helically over the bedding as per IEC 60502-1 or as per BS 5467, BS 6346. (Single core cables shall be Aluminium wire armoured)(SWA/AWA)
Double Steel Tapes applied helically over the bedding of multi-core cables as per IEC 60502-1.(STA)


Outer Sheath

Outer sheath will be extruded PVC/ST2 as per IEC 60502-1, Type 9 as per BS 7655. Special type of PVC sheathing material such as fire retardant PVC, anti-termite and anti-rodent PVC, ultraviolet PVC, Oil resistant PVC, etc. Are available on request also other special sheathing materials such as LLDPE, MDPE, HDPE, LSF, CPE etc are available.

Flame Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, can also supply cables with Low Smoke Halogen Free (LSHF) material according to IEC 60502-1, BS 7211, BS 6724 or other equivalent standards.

 

Standard:

IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer

Type and Name:

TypeDesignationApplications
VVCopper conductor, PVC insulated, PVC sheathed power cableFor laying indoors, in tunnel or cable trench, unable to bear external mechanical forces
.Single core cable is not allowed to lay in a magnetic duct.
VLVAluminum conductor, PVC insulated, PVC sheathed power cable
VYCopper conductor, PVC insulated, PE sheathed power cable
VLYAluminum conductor, PVC insulated, PE sheathed power cable
VV22Copper conductor, PVC insulated, steel tape armored, PVC sheathed power cableFor laying indoors, in a tunnel in cable trench, or direct in ground,
able to bear external mechanical forces.
The single-core cable is not allowed to lay in the magnetic duct.
VLV22Aluminum conductor, PVC insulated, steel tape armored, PVC sheathed power cable
VV23Copper conductor, PVC insulated, steel tape armored, PE sheathed power cable
VLV23Aluminum conductor, PVC insulated, steel tape armored, PE sheathed power cable
VV32Copper conductor, PVC insulated, steel wire armored, PVC sheathed power cableFor laying indoors, in tunnel cable trench, well or direct in ground, able to bear
 external mechanical forces and certain pulling force.
VLV32Aluminum conductor, PVC insulated, steel wire armored, PVC sheathed power cable
VV33Copper conductor, PVC insulated, steel wire armored, PE sheathed power cable
VLV33Aluminum conductor, PVC insulated, steel wire armored, PE sheathed power cable

Type and Name:

TypeDesignationApplications
YJVCopper conductor, XLPE insulated, PVC sheathed power cableFor laying indoors, in tunnel or cable trench, unable to bear external mechanical forces
.Single core cable is not allowed to lay in a magnetic duct.
YJLVAluminum conductor,XLPE  insulated, PVC sheathed power cable
YJYCopper conductor, XLPE insulated, PE sheathed power cable
YJJLYAluminum conductor, XLPE insulated, PE sheathed power cable
YJV22Copper conductor,XLPE  insulated, steel tape armored, PVC sheathed power cableFor laying indoors, in a tunnel in cable trench, or direct in ground,
able to bear external mechanical forces.
The single-core cable is not allowed to lay in the magnetic duct.
YJLV22Aluminum conductor, XLPE insulated, steel tape armored, PVC sheathed power cable
YJV23Copper conductor, XLPE insulated, steel tape armored, PE sheathed power cable
YJLV23Aluminum conductor, XLPE insulated, steel tape armored, PE sheathed power cable
YJV32Copper conductor, XLPE insulated, steel wire armored, PVC sheathed power cableFor laying indoors, in tunnel cable trench, well or direct in ground, able to bear
 external mechanical forces and certain pulling force.
YJLV32Aluminum conductor, XLPE insulated, steel wire armored, PVC sheathed power cable
YJV33Copper conductor, XLPE insulated, steel wire armored, PE sheathed power cable
YJLV33Aluminum conductor, XLPE insulated, steel wire armored, PE sheathed power cable
Cable Technical data sheet
 
No. x mm2PhaseNeutral/EarthInner sheathArmoredOuter sheathWeight of Cable
Diameter of conductor  mmThickness of XLPE  mmDiameter of conductor  mmThickness of XLPE  mmThickness   mmDiameter of wire
mm
Thickness of Sheath  mmComplete Diameter mmYJV32(CU)
kg/km
YJLV32(AL)
kg/km
4*1.51.380.7--10.81.814.3391.3353.7
4*2.51.780.7--10.81.815.3459.7397.2
4*42.250.7--10.81.816.4551.7451.8
4*62.760.7--11.251.818.6800.7650.4
4*1040.7--11.251.821.61089.3837.6
4*165.10.7--11.61.824.915431151.1
4*256.30.9--11.61.828.82094.71481.8
4*356.20.9--11.61.92723861531.9
4*507.61--11.6230.73014.11858.5
4*708.81.1--1.222.235.44298.92603.3
4*9510.51.1--1.222.339.35480.43149.3
4*12011.21.2--1.42.52.543.16972.24033.1
4*150131.4--1.42.52.648.28452.24784.6
4*18514.51.6--1.62.52.853.110276.85704.9
4*24016.21.7--1.62.5357.712650.16721.6
4*300191.8--1.62.53.264.715397.17986.5
3*2.5+1*1.51.780.71.380.710.81.815.1442.9386.6
3*4+1*2.52.250.71.780.710.81.816.1527.8437.3
3*6+1*42.760.72.250.711.251.818.3776.2638.6
3*10+1*640.72.760.711.251.820.81014787.7
3*16+1*105.10.740.711.251.823.61322.2965.4
3*25+1*166.30.95.10.711.61.827.81953.61395.9
3*35+1*166.70.95.10.711.61.828.82295.11556.6
3*50+1*257.416.30.911.61.931.12847.61827.7
3*70+1*358.71.170.91.222.136.24015.52530.3
3*95+1*5010.51.18.211.222.240.55076.73039.4
3*120+1*7011.61.2101.11.222.443.96227.13598.8
3*150+1*70131.4101.11.42.52.549.77816.54641.9
3*185+1*9514.51.611.61.11.42.52.754.59503.85492.1
3*240+1*12016.51.7131.21.62.52.960.411746.46565.3
3*300+1*15018.81.814.61.41.62.5366.3141267651.2
3*2.5+2*1.51.780.71.380.710.81.815.8484.5418.8
3*4+2*2.52.250.71.780.711.251.817.8702.1596
3*6+2*42.760.72.250.711.251.819.2853.3690.7
3*10+2*640.72.760.711.251.821.71110846.1
3*16+2*105.10.740.711.61.825.61635.81216.1
3*25+2*166.30.95.10.711.61.829.32182.11526.4
3*35+2*166.50.95.10.711.61.829.12453.21616.7
3*50+2*257.416.30.911.6232.23125.61952.5
3*70+2*3591.170.91.222.137.94482.42783.7
3*95+2*5010.71.18.211.222.342.45679.23353.1
3*120+2*70121.2101.11.42.52.547.87499.74447.5
3*150+2*7013.41.4101.11.42.52.652.38649.75051.2
3*185+2*95151.611.61.11.62.52.857.910681.16086.6
3*240+2*120171.7131.21.62.5363.613074.77158.8
3*300+2*15019.21.814.61.41.62.53.269.715769.38377.6
4*2.5+1*1.51.780.71.380.710.81.816501.6429.7
4*4+1*2.52.250.71.780.711.251.818.1732.4616.9
4*6+1*42.760.72.250.711.251.819.5888.2713
4*10+1*640.72.760.711.251.822.41172.6883.3
4*16+1*105.10.740.711.61.826.21716.51261.7
4*25+1*166.30.95.10.711.61.830.22304.31593.4
4*35+1*1670.95.10.711.61.931.92748.91796.8
4*50+1*254.916.30.91.222.130.33418.12109.3
4*70+1*356.21.170.91.222.236.84720.12811
4*95+1*507.51.18.211.222.441.26035.13415.1
4*120+1*707.91.2101.11.42.52.54678224459
4*150+1*709.21.4101.11.42.52.749.89267.45175.9
4*185+1*9510.51.611.61.11.62.52.955.611326.36171.6
4*240+1*12012.81.7131.21.62.53.162.614109.67446.4
4*300+1*150151.814.61.41.83.153.371.518037.89710.3

Note:
Galvanized Steel Wires applied helically over the bedding as per IEC 60502-1 or as per BS 5467, BS 6346.
Single core cables shall be Aluminium wire armoured)
1000V Nyy-J N2xry Yjv32 VV32 Swa Sta Armoured Power Cable XLPE Cable
1000V Nyy-J N2xry Yjv32 VV32 Swa Sta Armoured Power Cable XLPE Cable1000V Nyy-J N2xry Yjv32 VV32 Swa Sta Armoured Power Cable XLPE Cable1000V Nyy-J N2xry Yjv32 VV32 Swa Sta Armoured Power Cable XLPE Cable1000V Nyy-J N2xry Yjv32 VV32 Swa Sta Armoured Power Cable XLPE Cable1000V Nyy-J N2xry Yjv32 VV32 Swa Sta Armoured Power Cable XLPE Cable1000V Nyy-J N2xry Yjv32 VV32 Swa Sta Armoured Power Cable XLPE Cable