Wxgs-V Underground Pipe Line Locator Cable Route Tracer Line Cable Fault Finder Tester

China Wxgs-V Underground Pipe Line Locator Cable Route Tracer Line Cable Fault Finder Tester, Find details about China High Voltage Tester, Cable Fault Locator from Wxgs-V Underground Pipe Line Locator Cable Route Tracer Line Cable Fault Finder Tester

Model NO.
WXGS-V
Certification
CE
Customized
Non-Customized
Color
Black
Accuracy
0-5m: ±5% 5-10m: ±10%
Depth of Probing
Direct: 5m / Coupling: 3m
Receiver Dimensions
27.6 * 4.3 * 3.7 Inch
Transmitter Dimensions
12.6 * 6.3 * 5.1 Inch
Receiver Weight
5.1kg
Transmitter Weight
7.9kg
Matched Load
5 Digits
Trademark
WG HIPOT
Specification
180*300*400mm
Origin
China
Model NO.
WXGS-V
Certification
CE
Customized
Non-Customized
Color
Black
Accuracy
0-5m: ±5% 5-10m: ±10%
Depth of Probing
Direct: 5m / Coupling: 3m
Receiver Dimensions
27.6 * 4.3 * 3.7 Inch
Transmitter Dimensions
12.6 * 6.3 * 5.1 Inch
Receiver Weight
5.1kg
Transmitter Weight
7.9kg
Matched Load
5 Digits
Trademark
WG HIPOT
Specification
180*300*400mm
Origin
China

Product Description

WXGS-V Underground Pipe Line Locator Cable Route Tracer Line Cable Fault Finder Tester

Features:

1. Digital multifunctional cable detection of Comprehensive Machine
2. Solution to live cable routing problems cannot be solved at present
3. You can find the buried cable jacketing damage to ground short circuit and open - circuit fault
4. Can be recognition required cable in multi-charged cables
5. Configuration rechargeable batteries, may completed all the tests without electricity

Find the path of the live cable
You can easily solve the paths find problem in the live cable. Put the coupling clamp to the under test cable, Transmitter coupling signals by coupling clamp on target cable, Path along the cable can receive the signal applied from the transmitter. Such method can detect the cable length is not less than 3 km. The receiver can detect the 50Hz frequency signals from the live cable, this method to distinguish the live cable and the disconnected cables is very useful. In this way, does not need to use transmitter.

Blind testing of underground cables
In some cases, Operator cannot close to the cable to connect directly or using coupling clamp, you can use the built-in induction antenna of transmitter to send output signal, Signal will induction to the measured underground cables for locating exploration, This method to detect Cable Depth will not less than 2 meters.

Find Buried cable fault
WXGS-V Cable Tracer can be applied step voltage method to determine the buried cable fault of ground insulation less than 2Mohm. Signal strength method can also be used to determine open and short cable fault. WXGS-V Cable Tracer has changed the traditional concept of cable fault location, without high voltage test equipment, without the use of AC power, no analysis of waveforms, Connection of simple and straightforward, A look that will be used.

Identification of live cables
Coupling the emissions clamp of transmitter on the cable, couple the receiver clamp on the cable exposure of the other side, At this point the strength of the signal can be determine which one is the applied signal cable.(This method requires a special clamp for receiver.)

Product Parameters

 

SPECIFICATIONS

Way of working

Peak method, valley method, A-frame method

Cable routing

Direct / Coupling / Induction

Cable Identification

Direct Connect (power cut) / coupling (has power)

Power Supply

Rechargeable Batteries

Operating Freq

Low freq, Mid Freq, Hi freq, RF, 50Hz

Clamp Config

Disconnected cable: 1 clamp / Live cable: 2 clamps

Accuracy

0-5m: ±5%       5-10m: ±10%

Depth of Probing

Direct: 5m / Coupling: 3m

Dimensions (L*W*H ins)

Receiver: 27.6 x 4.3 x 3.7 / Transmitter: 12.6 x 6.3 x 5.1

Weight (lbs)

Receiver: 5.1kg / Transmitter: 7.9kg

Transmitter

Operating Freq

Low freq, Mid Freq, Hi freq, RF

Mode

Direct-connect, coupling and inductive method

Matched load

5 ohms ~ 3000 ohms

Display

5 digits

Output power

maximum outpower >8w

Receiver

Operating Freq

Low freq, Mid Freq, Hi freq, RF, 50Hz

Current indication

Display the effective current value of the cable under test

Detection depth

Max depth > 5 meters (straight method)

Maximum range

Straight method with good insulation cables up to 15KM

Accuracy

Low freq ± (1-5)% 2.5m       RF: ± (5-12)%  2.5 m

Packaging & Shipping

Wxgs-V Underground Pipe Line Locator Cable Route Tracer Line Cable Fault Finder Tester
Wxgs-V Underground Pipe Line Locator Cable Route Tracer Line Cable Fault Finder Tester
 

Company Profile

Wxgs-V Underground Pipe Line Locator Cable Route Tracer Line Cable Fault Finder Tester
Wuhan WG Hipot Electric Tester Co.,Ltd. is the professional factory of high voltage testing equipment with over 15 years industry experience.

ISO Certified factory, qualified R&D and after-sales Engineer team, 3000 square meters workshop, our 
high voltage testers cover full range: High voltage hipot tester, Circuit breaker Switchgear Tester, Transformer tester, Relay Protection Tester, CT/PT Tester, MOA/Insulator Tester, SF6/Insulation Oil Test Equipment, Resistance Tester, etc.

Since 2003, with the support from our investors 
Wuhan High Voltage Institution and Xi'an High Voltage Institution, WG Hipot established and pioneered in high voltage testing field in domestic market as the designated supplier for State Grid and mainstream power companies.

Meantime, WG Hipot has developed overseas markets across 5 continents worldwide. We gained good feedback from our customers with our high performance, good quality, customized specification and easy-to-operate high voltage testers, which can be widely used in railway, oil and chemical industry, electricity grid, university, big factory etc.

 

Certifications

Wxgs-V Underground Pipe Line Locator Cable Route Tracer Line Cable Fault Finder Tester
 

Filed Test&After-Sales service

Wxgs-V Underground Pipe Line Locator Cable Route Tracer Line Cable Fault Finder Tester
1, Technical datas and operation manual sent for evaluation.
2, Tranining how to install and use the machine.
3, Engineers available to service machinery on site.

Customer Visit

Wxgs-V Underground Pipe Line Locator Cable Route Tracer Line Cable Fault Finder Tester

FAQ

1, Q: Are you manufacturer or trading company?
    A: We are manufacturer of more than 15 years in power testing products.

2, Q: How can the customer to pay?
    A: LC, TT, Western Union all accetable.

3, Q: Could CoulWhat's your terms of delivery?
    A: EXW, FOB, CFR, CIF All Acceptable. 

4, Q: Could you please tell me the Warranty Period of your product?
    A: Our warranty period is one year free and lifelong maintenance. If the product is damaged (if not man-made damage), in the first year,we will send free parts for replacement. Over warranty, maintenance is paid service.

5. Q: What kind of Certificate can you provide?
    A: We can provide the CE mark, ISO 9001 quality certificate, third party calibration certificate(CNAS) and factory test report.

6. Q:Do you have Technical Backup to all customers from different countries?
    A: To be sure,our technical support is always available and quick response.
We are manufacturer with much on-site testing experience, thus we know how to deal with your problems. Moreover, our engineers can go to your country to support if need.