ISO 9705 Room Corner Flammability Testing Equipment Burning Chamber

China ISO 9705 Room Corner Flammability Testing Equipment Burning Chamber, Find details about China Burning Chamber, Flammability Testing Equipment from ISO 9705 Room Corner Flammability Testing Equipment Burning Chamber

Model NO.
GD9705
HS Code
9031809090
Model NO.
GD9705
HS Code
9031809090

ISO 9705 Room Corner Flammability Testing Equipment Burning Chamber
ISO 9705 Room Corner Flammability Testing Equipment Burning Chamber

Introduction: 

ISO 9705 Room Corner Flammability Testing Equipment Burning Chamber (RCT), as ISO' s the evaluation of fire-resistance performance of building materials, measures heat release rate (H.R.R), smoke generation rage, oxygen consumption, CO, CO2 production and so on. 

As basis of ISO 9705(Fire tests - Full scale room test for surface products), RCT is the test that reproduces local fire conditions by flame combustion in the small room of building structure and measures fire movement and combustion diffusion in the building structure.

Standard:

ISO9705

Fire test-Full scale room test for surface products
ISO 13784-1Reaction to fire tests for sandwich panel building systems 
ASTM E 1537Standard Test Method for Fire Testing of Upholstered Furniture
ASTM E 603 Standard Guide for Room Fire Experiments
EN 14390Fire Test - Full Scale Room Test for Surface Products
NFPA 265Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls
NFPA 286Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth


Specification:

Product NameISO 9705 Room Corner Flammability Testing Equipment Burning Chamber
SizeTest Room (mm) 
3,600 (w) × 2,400 (d) × 2,400 (h) 

Hood  (mm) 
3000 (w) × 3000 (d) × 2950 (h) 

Sandbox Burner (mm) 
170 (w) × 170 (d) × 145 (h)
Power220V AC, 60Hz, 10A
Exhaust3.5m3/s
UtilitiesPropane Gas Valve System; Ignition System


Feature: 

1, Hood Skirt: Hood for collection of flue gases and prevention of flue gases of overflow.

2, Strainer for securing stable flow.

3, Suction pump for drawing gases generated in duct to the Control Lab.


Test Result: 

1. Heat Release Rate;

2. Smoke Product Rate;

3. Consumption and yield measurement of O2, CO and CO2;

4. Analysis of other toxic gases (Others Toxic Gas By FT-IR);

5. Measurement of change in temperature of entrance.


Our Services:

*Consulting support. 

*Sample testing support.

*Factory Visiting

*Training support

*Installation support

*24 Hours &7 days service