Medical equipment, invasive patient monitor, ICU monitor, measure artery monitor
medical monitor, hospital monitor , invasive monitor
MONITOR (for measure artery, invasive)
ICU Monitor
Multi-Para Patient monitorFeatures &Benefits:- 10.4" color TFT display, high resolution 800×600 dpi;
- Separated para board: ECG, NIBP, SpO2 board;
- Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.
- Real time S-T segment analysis, and ARR analysis;
- SpO2 Pitch Tone Variation and Drug Dose Calculation;
- Parameter waveform and characters color selectable
- Multi and unique display: Standard, Large font, Trend Coexis, OxyCRG dynamic
- Standby mode for Energy saving and suspend monitoring;
- 7-lead ECG waveforms display in phase;
- Capture dynamic waveforms;
- Built-in rechargeable lithium battery, and battery volume checking.
- Efficient resistance to interference of defibrillator and HF knife;
- SINNOR F-6 SpO2 technology, VS NELLCOR accuracy;
- TCP/IP networking platform enable abundant future upgrade
- Complete and flexible mounting solution for transportation and in-patient monitoring
Standard parameters: 5-lead ECG, RESP, HR, NIBP, SPO2(F-5), 1-TEMP, PR;Optional: Touch Screen, Thermal Recorder, 3/12- lead ECG,SD card,2/ 4-IBP,EtCO2, SpO2(F-6) Performance SpecificationsDisplay: 10.4''color TFTRolling and refreshing waveform displayResolution: 800×600Multi display selectable including:Large-font displayTrend coexist displayOxyCRG dynamic view display.Bed-to-bed view displayTrace: 7 waveforms(5 ECG, 1 SPO2 and 1 RESP)Sweep speed:6.25mm/s, 12.5mm/s,25mm/s,50mm/sIndicator: Power/battery indicator lightQRS beep and alarm soundBattery: Rechargeable lead acid cell, 12v/4AHMax.24 hour for charging, 4 hours for continue workingTrend: Parameter graphic and tabular trends:5s/piece,8 hours;1min/piece,168 hours(24hour×7days)5min/piece,1000 hours.Storage: NIBP:1000 groupsAlarm:200 groupsFull disclosure waveforms: 3600SAlarm: User-adjustable High, Medium and Low limits 3-level Audible and visual alarmNetworking: Connected to central monitoring systemTCP/IP netting platformRecorder: Build-in, thermal arrayPlethysmogram caveform:2 channelsRecord mode: manual, on alarm, time-defined Recording width: 50mmPrinting speed: 50mm/sRecording type: Frozen waveform recordNIBP recall recordTrend table recordAlarm recordFixed -time recordStandard Parameter:ECG:Lead mode: 5 -lead(R,L,F,N,C)Lead selection : I,II,III,avR,avL,avF,VWaveform: 3 and 7 channel selectableGain selection: 0.5mm/mv,1mm/mv,2mm/mvSweep speed: 12.5mm/s;25mm/s;50mm/sHeart rate range: Adult: 15~300bpm; Neonate:/pediatric:15~350bpmAccuracy: +1bpm or +1%,whichecer is greaterResolution: 1bpmFilter: surgery mode:1~20Hzmonitor model:0.5~40HzDiagnostic mode:0.05~130HzScaling signal: 1mv,+3%Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillationAlarm range: 15~350bpmS-T segment detecton: Measurement range: 2.0mV~+2.0mV Alarm Range: -2.0mV~ +2.0mVAccuracy: -0.8mV ~+0.8MvError: +0.02Mv Arrhythmia analysis: YESSPO2Measurement range: 0~100%Resolution: 1%Accuracy: +2%(70-100%);0-69% unspecifiedAlarm range 0~100%Pluse Rate: range:20~300bpmResolution:1bpmError:+1bpm or +2%,whichever is greaterNIBPMethod: Digital Automatic oscillometricOperation mode : Manual/Automatic/continuousAuto measurement time: Adjustable(1~480min)Measurement Unit: mmHg/Kpa selectableMeasurement types: Systolic, Diastolic, Mean Measurement tange:Range of Systolic pressure: Adult: 40~270mmHgPediatric: 40~220mmHgNeonate: 40~135mmHgRange of mean pressure: Adult: 20~235mmHgPediatric: 20~165mmHgNeonate: 20~110mmHgRange of diastolic pressure: Adult: 10~215mmHgPediatric: 10~150mmHgNeonate :10~100mmHgOver-pressure protection: Double safety protectionResolution: 1 mmHgAlarm: Systolic.Diastolic,MeanRESPIRATIONMethod: Thoracic impedanceMeasurement range: Adult:7~120rpm;Neonate/Pediatric:7~150rpmApnea alarm: YES,10~40sResolution: 1rpmAccuracy: +2rpmTEMPERATURECompatible probe: YSI or CYFMeasurement range: 5~50ºCResolution : 0.1ºCAccuracy: +0.1ºCRefreshing time: about 1Average measuring time: <10sMiscellaneousSatety: Safety level: Class I, type CFOperation EnvironmentTemperature: Working 0~+40ºCTransportation and storage -20~+60ºCHumidity: working≤85%Transportation and storage≤93%Power: AC 100-240,50/60HzPatient range: Neonate, pediatric, adult patientsAccessories supplies(1) 5 lead ECG cable (2) 1 spo2 probes (3) 1 NIBP prbe (4) 1 temp probe(5)1 ground connecting liner (6) Chest electrode (10pcs/set)