RCD Protected Raised Floor Box with 3 Gang Access Floor Socket/Floor Socket

China RCD Protected Raised Floor Box with 3 Gang Access Floor Socket/Floor Socket, Find details about China RCD, Access Floor Socket from RCD Protected Raised Floor Box with 3 Gang Access Floor Socket/Floor Socket

Model NO.
HTD-626AS-RCD
Certification
CCC, CE, RoHS, ISO: 9001, OHSAS18001
Customized
Customized
Condition
New
Place of Origin
Zhejiang, Wenzhou, China
Keyword
Raised System Floor Boxes
Rated Current
10-25A
Voltage
110~240V
Current Type
AC
Frequency
50Hz~60Hz
Available Modules
Type 45
Interface Size
3 Compartment
Company Certificate
ISO(9001, 14001), OHSAS18001
Producet Certificate
Ce by TUV, CCC, RoHS
Trademark
Safewire or OEM brand
Transport Package
Inner Packing Box Outer Exporting Carton
Origin
China
HS Code
8536690000
Model NO.
HTD-626AS-RCD
Certification
CCC, CE, RoHS, ISO: 9001, OHSAS18001
Customized
Customized
Condition
New
Place of Origin
Zhejiang, Wenzhou, China
Keyword
Raised System Floor Boxes
Rated Current
10-25A
Voltage
110~240V
Current Type
AC
Frequency
50Hz~60Hz
Available Modules
Type 45
Interface Size
3 Compartment
Company Certificate
ISO(9001, 14001), OHSAS18001
Producet Certificate
Ce by TUV, CCC, RoHS
Trademark
Safewire or OEM brand
Transport Package
Inner Packing Box Outer Exporting Carton
Origin
China
HS Code
8536690000
Specifications

1.Floor box  manufactured  from galvanised  steel
2.25 & 20mm  knockouts  to accept  flexible conduit
3.Frame &  lid moulded  from high  impact ABS plastic material
4.Galvanised  lid insert  for strength
5.Easy grip  recessed  lifting handle
6.Compact  design 310 x 220 mm floor  cut-out
7.Clamp fixing  for fast  installation
8.Standard  depth 99mm  designed  to accepts standard
9.accessory  plates from  electrical  wholesalers


Dimensions
Serial No.ParameterDescription
1Floor Cut  Out310x 220 mm
2Floor Box  Depth99mm
3Plug Top Clearance38mm
4Overall  Frame & Lid320.5*230.5mm
5Frame Lid  Recess8mm
6Accessories  Plates177*90mm
 

RCD Protected Raised Floor Box with 3 Gang Access Floor Socket/Floor Socket
 
General Description

The RCD devices provide protection against electric shock, in the event of a fault developing within the appliance  or an accident such as cutting through the mains lead. The double pole device within the unit provides complete isolation from the mains when tripped. The RCD are complying with BS7288 and BS1363 defined.
This socket has been designed for storage and use between -5ºC and +40ºC and at an altitude of no greater than 2000 metres above sea level.

RCD Protected Raised Floor Box with 3 Gang Access Floor Socket/Floor Socket
These devices with unique mechanical suspension means (latching pin) Closing the contacts will open automatically if there is an interruption in the mains supply.

Technical Specification:
1.  RCD Type:                                Latching pin
  2.  Voltage Rating:                       240V AC
  3. Current Rating:                       13A
  4. Rated Tripping Current:           30mA
  5. Breaking Capacity:                  250A
  6. Short Circuit Withstand:          1500A
  7. Ambient Operating Temp:       -5ºC to +40ºC
8. Operating Speed:                      < 40mS
9. Contact Break:                          Double Pole
10. Specifications:                        RCD Module-BS7288, Socket-BS1363
11. Minimum Back Box Depth:     35mm
12. Fixing Screws:                        M3.5X37mm
13. Cable Capacity:                     5X2.5mm2,2x4mm2,1X6mm2

To ensure a long life and efficient working of these products they should not be subjected to mistreatment or abnormal conditions such as smoke, chemical fumes, salt spray or long term high humidity.

Operation:
The RCD socket should be tested (as below) each time before use.
Testing Procedure
1) Remove appliance plugs from sockets.
2) If the red signal flag is not visible in the status window, press the dark green button (Reset).
3) The red flag should appear in the status window. If the red flag does not appear it may mean that there is no mains supply fed to the socket. If mains supply is being fed to the socket and the red flag does not appear, see 'Safety                             Notes' below.
4) Press the blue button (Test). The red flag should disappear. If the red flag remains visible, do not use. See 'Safety Notes' below.
5) Reset the device by pressing the dark green button (Reset). The red flag should reappear in the status window.

Safety Notes:
1) If the device does not operate in the way described in 'Test Procedure' above, do not use. It is likely that the RCD, device is faulty and should be returned to the vendor from whom it was purchased.
2) No attempt should be made to repair the RCD socket. The units are sealed to prevent tampering and any damage to this seal will invalidate the guarantee.
3) This s.r.c.d. has been designed for storage and use between -5ºC and +40ºC, with an average value not exceeding +35ºC measured over 24h period. And at an altitude of not greater than 2000m above sea level.
4) Care must be taken not to subject your s.r.c.d. to abnormal pollution by smoke, chemicals or flammable fumes, salt-laden spray, prolonged periods of high humidity, immersion, repeated dropping or other abnormal conditions.
5) Electricity is dangerous and an RCD must not be used as a substitute for normal precautionary measures. Always unplug from mains supply before any inspection or repair to equipment. Do not allow children to tamper with electrical devices.
6) Seek advice from the manufacturer, responsible vendor or a competent electrician       if the s.r.c.d. repeatedly trips with an appliance connected or if it should fail to trip when tested in accordance with the instructions.

Using the RCD Socket:
1) Insert the plug(s) of the appliance(s) you wish to use.
2) The RCD socket should remain set and the appliances should work normally. The red flag will remain visible. In the  status window. If the action of plugging in the appliance causes the device to trip (the red flag will disappear from the window), it is likely that there is a fault with the appliance. Consult a qualified electrician (see following note).

Installation for RCD instructions:
Switch off the mains supply and remove the appropriate fuse or switch off the appropriate circuit breaker before commencing installation. Ensure that no one else has access that would enable the supply to be inadvertently reconnected.
These accessories must only be installed by a competent person and in accordance with the current edition of the IEE Wiring Regulations (BS 7671: Requirements for Electrical installations) and any applicable statutory regulations.

RCD Protected Raised Floor Box with 3 Gang Access Floor Socket/Floor Socket
Drawing line
RCD Protected Raised Floor Box with 3 Gang Access Floor Socket/Floor Socket
Package :
  1. Package dimension of carton: 55 X 37 X29 mm; 4 Pcs inner box into master carton
  2. G.W.:14.2KG/Carton; N.W: 13.2KG/Carton