Indoor Vacuum Lateral Type 17.5kv/1600A Circuit Breaker

China Indoor Vacuum Lateral Type 17.5kv/1600A Circuit Breaker, Find details about China Vacuum 17.5kv Breaker, Indoor Vacuum Lateral Type Circuit Breaker from Indoor Vacuum Lateral Type 17.5kv/1600A Circuit Breaker

Model NO.
VB4/S
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
IEC
Product Name
Lateral Type 17.5kv/1600A Circuit Breaker
Application
Overvoltage Protection
Rated Current
1600A
Rated Voltage
17.5kv
Standard
IEC62271-100
Trademark
farady
Transport Package
Wooden Case
Origin
Zhejiang, China
HS Code
8535210000
Model NO.
VB4/S
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
IEC
Product Name
Lateral Type 17.5kv/1600A Circuit Breaker
Application
Overvoltage Protection
Rated Current
1600A
Rated Voltage
17.5kv
Standard
IEC62271-100
Trademark
farady
Transport Package
Wooden Case
Origin
Zhejiang, China
HS Code
8535210000
General
VB4/S medium-voltage indoor vacuum circuit breaker is applicable for three-phase AC power system of rated voltage up to 7.2kV~24kV and frequency 50/60HZ,widely used in many fields such as power plant, transformer substation, petrol chemical industry, metallurgy, manufacturing industry, airport, residential area, etc., to control and protect the electric equipment, especially, It is used for the occasion that needs infrequent operation at rated current or multi-breaking short circuit current, may be mounted in the indoor air insulating switchgear like type HXGN ring main uint series, etc. This circuit breaker is standards as GB1984-2003 AC high voltage circuit breaker,JB3855 3.6-40.5Kv indoor AC High voltage circuit breaker,DL/T403 Specification of 12-40.5Kv indoor High voltage vacuum circuit breaker for order as well as IEC60694.
This circuit breaker is made with mature APG technology. The application of VB4/S terminal buffer guarantees the indoor terminal is ever more reliable in nay operation environment. VB4/S can fully meet the requirement of GB, DL, IEC, DIN, VDE as well as standards of other advanced industrial countries. 

Service condition

a) Air temperature: Maximum temperature: +40ºC; Minimum temperature:-25ºC

b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .

c) Altitude above sea level: Maximum installation altitude: 2500m

d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.

e) No frequent violent shake

Technical data
Indoor Vacuum Lateral Type 17.5kv/1600A Circuit Breaker
Detailed image

Indoor Vacuum Lateral Type 17.5kv/1600A Circuit Breaker
Certification
Indoor Vacuum Lateral Type 17.5kv/1600A Circuit Breaker
Packing & Delivery
Indoor Vacuum Lateral Type 17.5kv/1600A Circuit Breaker
Our company
Indoor Vacuum Lateral Type 17.5kv/1600A Circuit Breaker
Indoor Vacuum Lateral Type 17.5kv/1600A Circuit Breaker



Zhejiang Farady Powertech Co.,Ltd
TEL:0086-0577-61512688
Fax:0086-0577-61510628
Http:// faradypowertech.en.made-in-china.com