China Xenon Lamp Aging Test Chamber for Solar Simulation Test, Find details about China Solar Simulation Test Chamber, Aging Test Chamber from Xenon Lamp Aging Test Chamber for Solar Simulation Test
Model | ZH-XL-150 |
Interior sizes | W500×D500×H600mm |
Exterior sizes | W1050×D1050×1750mm (or so) |
Temp. range | 0ºC~80ºC |
Controller | imported programmable 7inch touch screen |
Material | inner and outer 304# stainless steel |
Sample holder | Aluminum alloy frame base |
Protection device | residual-current circuit breaker (RCCB) to control the warning for loop overload, thermal protection and water shortage protection. |
Temp. deflection | ±2ºC (without lighting) |
Humid. range | 30%~98%R.H |
Humid. deflection | ±2.5%R.H(Humid.≥75%R.H); ±3%R.H(Humid.≤75%R.H)(without lighting) |
Light source | imported full spectrum xenon arc lamp(average useful life 1600hrs) |
Raining time | 1~9999min (adjustable) |
Raining period | 1~240min, interval(cut)adjustable |
lamp power | Test period for Temp., irradiation, condensation, spray can be adjustable |
Lamp | 1.8KW |
Wave length range | 290-800nm |
heating power (or so) | 4.0KW |
humidification (or so) | 2.0KW |
Light irradiance | 1200w/m2 |
Distance between arc center and sample holder: | 350~380mm |
Revolving speed of sample holder | ≥1r/min |
Water spray period | a. spray time: 0~99h59min (Continuing or adjustable) b. stop time: 0~99h59min, (Continuing or adjustable) |
Lighting time | Continuing programming control available |
Black panel temp. | 85±3ºC |
Cooling method | Mechanical wind cooling; Room temp. less than 26ºC is recommend, relative humid: ≤85%R.H; humid. and temp. tested after 2 hours under idle condition. |