China Solar Product 220V 6kw Single Phase Grid Tie Solar Power Inverters, Find details about China Power Inverters, Solar Inverter from Solar Product 220V 6kw Single Phase Grid Tie Solar Power Inverters
Technical Data | Austa-1P3.6K1G | Austa-1P5K1G | Austa-1P6K1G | Austa-1P8K1G |
Energy source | Grid-connected PV | |||
Description | Solar Product 220v 6kw Single Phase grid tie solar power inverters | |||
Input Side | ||||
Max.DC Input Power(kW) | 4.68 | 6.5 | 6.6 | 8.8 |
Max.DC Input Voltage(V) | 500 | 500 | 500 | 500 |
Start-up DC Input Voltage(V) | 120 | 120 | 120 | 120 |
MPPT Operating Range(V) | 100-500 | 100-500 | 100-500 | 100-500 |
Max.DC Input Current(A) | 13+13 | 13+13 | 13+13 | 13+26 |
Number of MPPT/String per MPPT | 2/1 | 2/1 | 2/1 | 2/1+2 |
OutPut Side | ||||
Rated Output Power(kW) | 3.6 | 5 | 6 | 8 |
Max.Active Power(kW) | 4 | 5.5 | 6.6 | 8.8 |
Rated AC Grid Voltage(V) | 230 | 230 | 230 | 230 |
AC Grid Voltage Range(V) | 180-300 | 180-300 | 180-300 | 180-300 |
Rated Grid Frequency(Hz) | 50/60(Optional) | 50/60(Optional) | 50/60(Optional) | 50/60(Optional) |
Operating Phase | Single Phase | Single Phase | Single Phase | Single Phase |
Rated AC Grid Output Current(A) | 16 | 22 | 26 | 35 |
Max.AC Output Current(A) | 18 | 24 | 29 | 39 |
Output Power Factor | 0.8 leading to 0.8 lagging | |||
Grid Current THD | <3% | <3% | <3% | <3% |
DC Injection Current(mA) | <0.5% | <0.5% | <0.5% | <0.5% |
Grid Fequency Range | 47-52/57-62(Optional) | 47-52/57-62(Optional) | 47-52/57-62(Optional) | 47-52/57-62(Optional) |
Efficiency | ||||
Max.Efficiency | 97.3% | 97.5% | 97.5% | 97.7% |
Euro Efficiency | 97.1% | 97.3% | 97.3% | 97.5% |
MPPT Eifficiency | >99% | >99% | >99% | >99% |
Protection | ||||
Anti-islanding Protection | Integrated | |||
DC Reverse-Polarity Protection | Integrated | |||
DC Surge Protection | Integrated(Type II) | |||
AC Surge Protection | Integrated(Type II) | |||
AC Short Circuit Protection | Integrated | |||
AC Output Overcurrent Protection | Integrated | |||
Output Overvoltage Protection | Integrated | |||
AC Grid Monitoring | Integrated | |||
Ground Fault Monitoring | Integrated | |||
Insulation Resistance Protection | Integrated | |||
Residual Current Monitoring Unit | Integrated | |||
Temperature Protection | Integrated | |||
Integrated DC Switch | Optional | |||
General Data | ||||
Size(mm) | 330W*310H*172D | |||
Weight(kg) | 11 | |||
Topology | Transforemerless | |||
Internal Consumption | <1W(Night) | |||
Running Temperature | -25-60ÂșC | |||
Ingress Protection | IP65 | |||
Noise Emission(Typical) | <30dB | |||
Cooling Concept | Intelligent cooling | |||
Max.Operating Altitude Without Derating | 2000m | |||
Designed lifetime | >20years | |||
Operating Surroundings Humidity | 0-100% | |||
Features | ||||
DC Connection | MC-4 mateable | |||
AC Connection | IP65 rated plug | |||
Display | LCD1602 | |||
Interface | RS485/RS232 | |||
Certifications&Standers | ||||
Grid Regulation | IEC61727/ 62116/ 60068 /61683/ INMETRO (ABNTNBR 16149/ 16150) | IEC61727/ 62116/ 60068/ 61683 | IEC61727/ 62116/ 60068/ 61683 | INMETRO (ABNTNBR 16149/ 16150) /IEC62116 |
Safety Regulation | IEC /EN62109-1/2 | |||
EMC Regulation | IEC /EN61000-6-1 /61000-6-3 |