Dpette Digital Pipette Autoclavable Lower Barrel

China Dpette Digital Pipette Autoclavable Lower Barrel, Find details about China Comprehensive Range of Liquid Handling Protocols, Three Aspiration/Dispensing Speeds from Dpette Digital Pipette Autoclavable Lower Barrel

Model NO.
01-241X 01-242X 01-243X 01-244X
Characteristic
Autoclavable Lower Barrel
Battery
Efficient Lithium-Ion
Trademark
Biologix
Specification
CE, FDA, ISO
Origin
China
HS Code
39172200
Model NO.
01-241X 01-242X 01-243X 01-244X
Characteristic
Autoclavable Lower Barrel
Battery
Efficient Lithium-Ion
Trademark
Biologix
Specification
CE, FDA, ISO
Origin
China
HS Code
39172200
Dpette Digital Pipette Autoclavable Lower Barrel
Dpette Digital Pipette Autoclavable Lower Barrel

Characteristic
 

Comprehensive range of liquid handling protocols

Three aspiration/dispensing speeds

Motor-drive with built-in error control

Efficient lithium-ion rechargeable battery

Autoclavable lower barrel

 

Stands

dPette Digital Pipettes can be charged with a 1-place

charging stand, a 5-place charging stand, or directly through

the charging cable. (Charging stands sold separately.)

    Ordering Information
     

    Catalogue No.

    Channels

    Volume Range (uL)

    Increment (uL)

    01-241X

    10.5-10

     0.01

    01-242X

    15-50

     0.1

    01-243X130-3001
    01-244X1100-10005

     

    Dpette Digital Pipette Autoclavable Lower Barrel
    Dpette Digital Pipette Autoclavable Lower BarrelDpette Digital Pipette Autoclavable Lower Barrel


    Dpette Digital Pipette Autoclavable Lower Barrel
    1.What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

    2.What are autoclaving guidelines of plastics?

    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

    3.What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.