Horizontal Concealed Chilled Water Fan Coil Unit Ventilation Fan Coil

China Horizontal Concealed Chilled Water Fan Coil Unit Ventilation Fan Coil, Find details about China Fan Coil, Fan Coil Unit from Horizontal Concealed Chilled Water Fan Coil Unit Ventilation Fan Coil

Model NO.
EST series
Mounting
Ceiling Concealed
Lifetime
>20 years
Certification
CE
Condition
New
Coil
Hydrophilic Fin
Main Usage
Chiller, Heat Pump, Underfloor Heating
Pipe System
Two Pipe and Four Pipe System
Production Time
20 Days for Bulk Order
Rows
3 Rows
Air Outlet Static Pressure
0, 12, 30, 50PA
Air Return
Backward/Downward
Trademark
ESACIR
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Origin
Guangdong, Prc.
HS Code
8415830000
Model NO.
EST series
Mounting
Ceiling Concealed
Lifetime
>20 years
Certification
CE
Condition
New
Coil
Hydrophilic Fin
Main Usage
Chiller, Heat Pump, Underfloor Heating
Pipe System
Two Pipe and Four Pipe System
Production Time
20 Days for Bulk Order
Rows
3 Rows
Air Outlet Static Pressure
0, 12, 30, 50PA
Air Return
Backward/Downward
Trademark
ESACIR
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Origin
Guangdong, Prc.
HS Code
8415830000
Horizontal Concealed Chilled Water Fan Coil Unit Ventilation Fan Coil Unit
 
1. ESAICR Fan coil unit series
Horizontal Concealed Chilled Water Fan Coil Unit Ventilation Fan Coil

Ceiling concealed fan coil unit
High ESP ducted fan coil unit
Universal concealed fan coil unit
Floor standing exposed fan coil unit
Ultra thin exposed fan coil unit
Ceiling exposed fan coil unit
Ceiling cassette fan coil unit
Ceiling exposed & floor standing fan coil unit
Wall mounted fan coil unit

2. Ceiling concealed fan coil product application
Fan coil unit is the terminal of central air conditioning system. It consists of centrifugal fan and copper tube heat exchanger.The ceiling consealed fan coil unit can be embedded in the ceiling and merged with interior decoration. Only exposing tuyere, which save space and easy maintenance. Widely used in hotels, restaurants, factories, hospitals, exhibition hall, shopping malls, office rooms and other industrial and civil construction of the combined air-conditioning system to meet the cooling, heating and other requirements.

3. Ceiling concealed fan coil unit main components
(1) Fan 
Fans are double inlets multi-blade centrifugal type. All fans are statically and dynamically balanced.
(2) Motor
Single-phase motors are suitable for different voltages, such as 110V, 115V, 120V, 220V, 230V, 240V. All motors have 10 percent voltage utilization range and wired to unit terminal box. Motors are designed for long life.
(3) Drain pan
Dray pan is integrally attached to coil casings and ended with drain hose. All pans are galvanized for corrosion resistance and cover the entire coil.
(4) Water coil
Coils are 3-row as standard design together with 4-row design as option. High efficient hydrophilic aluminum fins are mechanically bonded to seamless copper tubes. All coils are specifically designed and circuited for water use. All coils are tested at 3.3MPa.
(5) Casing
Casing are constructed of heavy gauge steel. Interior surface of unit panels are acoustically and thermally insulated with polyethylene foam.
Units are furnished as standard with a 1 inch duct collar to facilitate connection of the supply air duct.
(6) Return air plenum (optional)
The fan coil unit shall be factory installed return air plenum that encloses the fan section of the unit. No field fabrication is required. The return air arrangement is adaptable between bottom or rear return of the plenum.
(7) Washable filter (optional)
Filter should be accessible from return air grille

Horizontal Concealed Chilled Water Fan Coil Unit Ventilation Fan Coil

4. Ceiling horizontal concealed fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Horizontal Concealed Fan Coil Unit (2 pipe system)
Model EST~200HC2300HC2400HC2500HC2600HC2800HC21000HC21200HC21400HC2
Air flow (m3/h)
(0/12Pa,30Pa Static Pressure)
High 34051068085010201360170020402380
Medium 2703805156607651040128015501800
Low 19026034043053071086010501280
Rated cooling capacity HTH(W)18002700360045005400720090001080012600
SH(W)134120122682335340235364670580469387
MTH(W)1485218729163645437458327290874810206
SH(W)115217282304288034554607575969118063
LTH(W)113417012268283534024536567068047938
SH(W)93013951860232527903720464955796509
Rated heating capacity HW2700405054006750810010800135001620018900
M207931194158519862378316103951247414553
L1634245032674084490165348168980111435
Horizontal Concealed Fan Coil Unit (4 pipe system)
Model EST~200HC4300HC4400HC4500HC4600HC4800HC41000HC41200HC41400HC4
Air flow (m3/h)
(0/12Pa,30Pa Static Pressure)
High 34051068085010201360170020402380
Medium 2703805156607651040128015501800
Low 19026034043053071086010501280
Rated cooling capacity HTH(W)18002700360045005400720090001080012600
SH(W)134120122682335340235364670580469387
MTH(W)1485218729163645437458327290874810206
SH(W)115217282304288034554607575969118063
LTH(W)113417012268283534024536567068047938
SH(W)93013951860232527903720464955796509
Rated heating capacity HW108016202160270032404320540064807560
M83212481663207924953326415849905821
L6549801307163419602614326739204574
Remarks:
(1)  Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)  Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature  60°C/50ºC.

 
5. Ceiling concealed fan coil unit features
(1) Excellent performance
(2) High reliability
(3) Easy maintenance
(4) Simple installation

 
Horizontal Concealed Chilled Water Fan Coil Unit Ventilation Fan Coil

Horizontal Concealed Chilled Water Fan Coil Unit Ventilation Fan Coil

6. FAQ

Q: How to choose the fan coil?
A:
(1) Firstly need to know the application site, for example, hotel room generally choose ceiling concealed fan coil, restaurant generally choose ceiling cassette fan coil, it depends on site requirements.
(2) If need to calculate cooling capacity, please get the acreage data.
(3) Confirm the pipe system: 2 pipe or 4 pipe according to the cooling and heating source.

Q: How to get a prompt quotation?
A: When you send the inquiry to us, please kindly provide the below technical information:
(a) Fan coil unit type: concealed, or exposed, ceiling installation or floor standing installation
(b) Cooling capacity: Kcal/hr or KW, TR, TONS, BTU/H
(c) Plenum box: Backward or downward, filter need or not
(d) Voltages and Frequency : V/PH/HZ
(e) Application:

Q: How about your service?
A: Our service
Before-sale services:
(1)Tell clients how to use our products and matters needing attention.
(2)Guide clients to choose the best and economic product, recover the investment within short time.
(3)Site inspection if client require.

In-sale services:
(1)Quality control must be inspect strictly.
(2)In accordance with the agrements stipulated in the contract.

After-sale services
(1)If the project needs our installation guidance, we can send our engineer and translator. We can also send customers installation video to teach them how to fix and operate with our product.
(2)Usually, our product warranty is 12 months since BL date, within this warranty period, all parts broken will be responsible for our factory.

 
7. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
Horizontal Concealed Chilled Water Fan Coil Unit Ventilation Fan Coil

8. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..
Horizontal Concealed Chilled Water Fan Coil Unit Ventilation Fan Coil