AC System Horizontal Chilled Water Ceiling Concealed Fan Coil Unit 1. Fan coil unit series
Ceiling concealed fan coil unit High ESP ducted fan coil unit
Universal concealed fan coil unit
Floor standing exposed fan coil unit
Ultra thin exposed fan coil unit
Ceiling exposed fan coil unit
Ceiling cassette fan coil unit
Ceiling exposed & floor standing fan coil unit
Wall mounted fan coil unit
2. Ceiling concealed fan coil brief description
Fan coil units are referred to as fan coils. It is one of the end devices of an air conditioning system consisting of a small fan, a motor and a coil (air heat exchanger). When the chilled water or hot water flows through the coil pipe, heat is exchanged with the air outside the pipe, the air is cooled, and the indoor air parameters are adjusted by dehumidifying or heating. It is a commonly used cooling and heating terminal device.
Available for following models:
Cooling capacity: 1.8KW to 12.6KW
Heating capacity: 2.7KW to 18.9KW
Air flow: 200 CFM to 1400 CFM
3. Ceiling concealed fan coil unit main components
(1)Casing
Panels and frame are made of galvanized steel, properly punched for fixing both accessories and the unit itself, either to wall (vertical version) or ceiling(horizontal version).
(2)Cooling/Heating Coil
The coils are made of seamless tubes expanded into aluminum fins in continuous block. The connections have brass headers with female fittings and provided with easily.
accessible vent and drainage valve.
(3)Fan deck
The fan decks are composed of double suction centrifugal fans with metal impellers and 3-speed fan motors. Each fan motor assembly is dynamically balanced.
(4)Filter
The easily removable filter is made of filtering honeycomb polypropylene fabric and supported by an aluminum or plastic frame.
(5)Drip tray
The drip trays are made from sheet metal treated with polyester powder coating to ensure total resistance to atmospheric agents. The "L" type tray makes the units suitable for both vertical and horizontal installation.
(6)Electrical connection box
All electric wires are connected to enclosed electrical terminal block, can be situated on the opposite side to the water connections.
4. Ceiling horizontal concealed fan coil unit technical specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Horizontal Concealed Fan Coil Unit (2 pipe system) |
Model EST~ | 200HC2 | 300HC2 | 400HC2 | 500HC2 | 600HC2 | 800HC2 | 1000HC2 | 1200HC2 | 1400HC2 |
Air flow (m3/h) (0/12Pa,30Pa Static Pressure) | High | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
Medium | 270 | 380 | 515 | 660 | 765 | 1040 | 1280 | 1550 | 1800 |
Low | 190 | 260 | 340 | 430 | 530 | 710 | 860 | 1050 | 1280 |
Rated cooling capacity | H | TH(W) | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
SH(W) | 1341 | 2012 | 2682 | 3353 | 4023 | 5364 | 6705 | 8046 | 9387 |
M | TH(W) | 1485 | 2187 | 2916 | 3645 | 4374 | 5832 | 7290 | 8748 | 10206 |
SH(W) | 1152 | 1728 | 2304 | 2880 | 3455 | 4607 | 5759 | 6911 | 8063 |
L | TH(W) | 1134 | 1701 | 2268 | 2835 | 3402 | 4536 | 5670 | 6804 | 7938 |
SH(W) | 930 | 1395 | 1860 | 2325 | 2790 | 3720 | 4649 | 5579 | 6509 |
Rated heating capacity | H | W | 2700 | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 |
M | 2079 | 3119 | 4158 | 5198 | 6237 | 8316 | 10395 | 12474 | 14553 |
L | 1634 | 2450 | 3267 | 4084 | 4901 | 6534 | 8168 | 9801 | 11435 |
Horizontal Concealed Fan Coil Unit (4 pipe system) |
Model EST~ | 200HC4 | 300HC4 | 400HC4 | 500HC4 | 600HC4 | 800HC4 | 1000HC4 | 1200HC4 | 1400HC4 |
Air flow (m3/h) (0/12Pa,30Pa Static Pressure) | High | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
Medium | 270 | 380 | 515 | 660 | 765 | 1040 | 1280 | 1550 | 1800 |
Low | 190 | 260 | 340 | 430 | 530 | 710 | 860 | 1050 | 1280 |
Rated cooling capacity | H | TH(W) | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
SH(W) | 1341 | 2012 | 2682 | 3353 | 4023 | 5364 | 6705 | 8046 | 9387 |
M | TH(W) | 1485 | 2187 | 2916 | 3645 | 4374 | 5832 | 7290 | 8748 | 10206 |
SH(W) | 1152 | 1728 | 2304 | 2880 | 3455 | 4607 | 5759 | 6911 | 8063 |
L | TH(W) | 1134 | 1701 | 2268 | 2835 | 3402 | 4536 | 5670 | 6804 | 7938 |
SH(W) | 930 | 1395 | 1860 | 2325 | 2790 | 3720 | 4649 | 5579 | 6509 |
Rated heating capacity | H | W | 1080 | 1620 | 2160 | 2700 | 3240 | 4320 | 5400 | 6480 | 7560 |
M | 832 | 1248 | 1663 | 2079 | 2495 | 3326 | 4158 | 4990 | 5821 |
L | 654 | 980 | 1307 | 1634 | 1960 | 2614 | 3267 | 3920 | 4574 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
5. Ceiling concealed fan coil unit features
(1) Excellent performance
(2) High reliability
(3) Easy maintenance
(4) Simple installation 6.Why choose EUROSTARS?
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Webiste 1: http://eurostarschiller.en.made-in-china.com/
Website 2: http://eurostarschiller.en.made-in-china.com/
Instagram: https://eurostarschiller.en.made-in-china.com
Facebook: https://eurostarschiller.en.made-in-china.com
Youtube https://eurostarschiller.en.made-in-china.com
1) With more certificate
2) Professional team with over more than 10 years industry knowledge
3) Oversea installation.
4) Customer-made accepted.
5) Diamond member of Made-In-China
6) Audited supplier by SGS
7. Our fan coil production line
Every fan coil has strict production process, including assembly, testing, packing.
8. Our service
Considerate after-sales service & product maintenance.You can contact us at any time.
Economical and energy-saving design scheme
Overseas engineer services
Integrated quality and profession R&D team
OEM/ODM available 9. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
10. Ceiling concealed fan coil installation instruction(1) Air duct must be fireproof regulations for buildings.
(2) For horizontal air supply, N≥150 MM; if air duct is longer than 1 m, N≥200 mm.
(3) Size of M depends on air duct installation. Pressure loss of circulatory air must be consistent with outlet static pressure of the unit.
11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..