Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed

China Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed, Find details about China Fan Coil, Water Chiller from Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed

Model NO.
EST-HE/VE series
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
CE
Condition
New
Motor
DC,Ec
Thermostat
0~10V Stepless (3 Speed Control Is Optional)
Main Usage
Chiller, Heat Pump, Underfloor Heating
Installation
Ceiling Mounted /Floor Standing
Production Time
20 Days for Bulk Order
Air Return
Front/Downward
Pipe System
Two Pipe and Four Pipe System
Trademark
ESACIR
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Origin
Guangdong, Prc.
HS Code
8415830000
Model NO.
EST-HE/VE series
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
CE
Condition
New
Motor
DC,Ec
Thermostat
0~10V Stepless (3 Speed Control Is Optional)
Main Usage
Chiller, Heat Pump, Underfloor Heating
Installation
Ceiling Mounted /Floor Standing
Production Time
20 Days for Bulk Order
Air Return
Front/Downward
Pipe System
Two Pipe and Four Pipe System
Trademark
ESACIR
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Origin
Guangdong, Prc.
HS Code
8415830000
Industrial Air Conditioners EC DC Fan Coil Unit Ceiling Exposed 

1. DC Ceiling exposed fan coil unit main components

(1) Fan
(2) Motor
(3) Drain pan
(4) Water coil
(5)Casing
(6)Return air plenum and filter

Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed

2. Ceiling exposed floor standing DC fan coil features
(1)Adopt famous branded high quality BLDC motor,high efficiency and low energy consumption;DC motor energy consumption is average less than 60% of AC motor.
(2)With long running life: as common AC motor is low operating efficiency,usually only 40~45% power consumption turn into kinetic energy,that means balance 55~60% energy is converted into heat,this heat may cause aging to motor components,which is harm to the motor life.DC brushless motor efficiency is always more than 80~95%,so only little energy changes to heat to prevent motor aging.
(3)Fast cooling/heating,temperature fluctuation is small,more comfortable.
a. If temperature difference between room temperature and setting temperature is big:
for normal AC style FCU,the fan will run under the setting speed;while the DC style will automatically run at high speed to make the room temperature to the setting temperature.
b. When the room temperature reach the setting temperature,the AC style fan coil will stop the fan running or close the water valve,this will cause the cooling/heating can not continue and there is temperature shock in the room;while the DC style fan coil will change its running speed according to the temperature difference between room temperature and setting temperature:if the distance is big, the fan speed will be higher,and if the distance is smaller ,the fan speed will be lower.
Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed
Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed
3. Ceiling exposed floor standing fan coil configuration
Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed

4. Ceiling exposed floor standing DC fan coil types
Four style universal fan coil unit can be selected:
Horizontal ceiling type with air return from downward without supporting legs
Floor standing type with air return from front with supporting legs
Horizontal ceiling type with air return from backward without supporting legs
Floor standing type with air return from bottom with supporting legs
Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed
 
5. Eurostars Fan coil unit series
Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed
1Ceiling concealed fan coil unit
2High ESP ducted fan coil unit
3Universal concealed fan coil unit
4Floor standing exposed fan coil unit
5Ultra thin exposed fan coil unit
6Ceiling exposed fan coil unit
7Ceiling cassette fan coil unit
8Ceiling exposed & floor standing fan coil unit
9Wall mounted fan coil unit

6. Ceiling floor standing exposed fan coil unit specification (DC motor)
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com

 
Universal Exposed Fan Coil Unit(2 pipe system)
Model   EST200HE2300HE2400HE2500HE2600HE2800HE21000HE21200HE21400HE2
200VE2300VE2400VE2500VE2600VE2800VE21000VE21200VE21400VE2
Power supply220V/1PH/50HZ
Air flow
 (m3/h)
H34051068085010201360170020402380
M/////////
L120160220270330420570670760
Cooling capacityTHHW18002700360045005400720090001080012600
SHW136820522736342041035471683982079575
THMW/////////
SHW/////////
THLW82611011514185822712891392346115231
SHW516688946116114191807245228823269
Heating capacityHW2700405054006750810010800135001620018900
MW/////////
LW123916522271278734074336588469177846
Universal Exposed Fan Coil Unit(4 pipe system)
Model   EST200HE4300HE4400HE4500HE4600HE4800HE41000HE41200HE41400HE4
200VE4300VE4400VE4500VE4600VE4800VE41000VE41200VE41400VE4
Power supply220V/1PH/50HZ
Air flow
 (m3/h)
MAX34051068085010201360170020402380
//////////
MIN120160220270330420570670760
Cooling capacityTHHW18002700360045005400720090001080012600
SHW136820522736342041035471683982079575
////////////
///////////
THLW82611011514185822712891392346115231
SHW516688946116114191807245228823269
Heating capacityMAXW130019402590324038905180648077809070
///////////
MINW5967911089133816362080282533223765

Remarks:
(1)  Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)  Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature  60°C/50ºC.

 
7.Why choose EUROSTARS?  
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
(1)With more certificate
(2) Professional team with over more than 10 years industry knowledge
(3) Oversea installation.
(4) Customer-made accepted.
(5) Diamond member of Made-In-China
(6) Audited supplier by SGS

Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed

8. Our fan coil production line
Every fan coil has strict production process, including assembly, testing, packing.

Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed
Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed

9. Our service and Customer visit
Pre-Sales Service
(1) Inquiry and consulting support.
(2) Sample testing support.
(3) View our Factory.
After-Sales Service
(1)Provide customers with installation and commissioning online instructions. And we also provide local whole project installation.
(2) Well-trained engineers available to overseas service.
(3) Worldwide agents and after-sale service available.

Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed

 
10. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed

11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..

Industrial Air Conditioners Ec DC Fan Coil Unit Ceiling Exposed