China Rapid-Rate Thermal Cycle Environmental Test Chamber, Find details about China Fast Change Rate Tester, Environmental Chamber from Rapid-Rate Thermal Cycle Environmental Test Chamber
Model | YICT-225 | YICT-306 | YICT-408 | YICT800 | YICT-1000 | ||||
Inner chamber size w×h×d(cm) | 50×75×60 | 60×85×60 | 50×85×80 | 100×100×80 | 100×100×100 | ||||
Exterior chamber size w×h×d(cm) | Depends on inner chamber size | ||||||||
Testing temperature range | -70~150ºC(KS);-40~150ºC(KL);-20~150ºC(KR) | ||||||||
Fast change temperature range | -70ºC kinds:-50~+85ºC(KS);-40ºC kinds:-20~+85ºC(KL);-20ºC kinds:0~+85ºC(KR) | ||||||||
Heating-up&Cooling-down speed | 3ºC/min,5ºC/min,8ºC/min,10ºC/min,15ºC/min(Linear or Non-linear) | ||||||||
Performance | Temp.fluctuation | ±2.0ºC | |||||||
Temp.uniformity | ±1.5ºC | ||||||||
Temp.resolution | 0.01ºC | ||||||||
Heating-up time | -70~150ºC<60min;-40~150ºC<50min;-20~150ºC<35min | ||||||||
Cooling-down time | +20~ -70ºC<70min;+20~ -40ºC<55min;+20~ -20ºC<35min | ||||||||
Material | Exterior chamber material | Cold-rolled steel+Powder coating | |||||||
Interior chamber material | SUS#304 Stainless steel | ||||||||
Insulation | PU fiberglass wool | ||||||||
System | Wind circulation | Cooling fan | |||||||
Heating system | SUS#Stainless steel high-speed heater | ||||||||
Refrigeration system | Imported tecumseh compressor+fin type evaporator+air(water)cooling system | ||||||||
Other components | Multi-layer vacuum glass observation window,cable port(50mm),controlling status indicator lamp,chamber light,specimenloading shelf(2pcs,position adjustable) | ||||||||
Safety protection device | Over-heat protection circuit breaker,compressor overload protection,control system overload protection,humidifying system overload protection indicator lamp | ||||||||
Power supply | AC 3phase380V 60/50Hz | ||||||||
Customization service | Non-standard or special requirements are all welcome |