GDCR4000A Digital Double-clamp Phase Volt- ampere Meter

China GDCR4000A Digital Double-clamp Phase Volt-ampere Meter, Find details about China Phase Volt-ampere Meter, Double-clamp Phase Volt-ampere Meter from GDCR4000A Digital Double-clamp Phase Volt-ampere Meter

Model NO.
GDCR4000A
Trademark
HV Hipot
Origin
Wuhan China
Model NO.
GDCR4000A
Trademark
HV Hipot
Origin
Wuhan China
GDCR4000A Digital Double-clamp Phase Volt-ampere Meter

GDCR4000A  Digital Double-clamp Phase Volt-ampere Meter is used to simultaneously measure the two channel AC voltage, current, phase between voltage, phase between current, phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, power factor, judge transformer connection group, inductive circuit and capacitive circuit, test secondary circuit and differential bus protection system, read the phase relation between CT groups, check meter wiring is correct or not, maintenance line equipment, etc

It is applicable to electric power, petrochemical, metallurgy, railway, industrial and mining enterprises, scientific research institutions, metrology departments, etc. It is especially suitable for the electric energy billing system and relay protection system, the electric energy measurement, electricity inspection and electric power inspection of the power supply Marketing Department, the installation and connection of the meter, relay protection, differential detection, starting test, substation maintenance of the production and technical department, or the electric power training and skill contest.

 
ModelClamp openingRemarks
GDCR 4000AΦ8mmSharp mouth
GDCR 4200A35*40mmRound mouth
 

Specification

Reference condition & working condition
FactorReference conditionWorking conditionRemarks
Ambient temperature23ºC±1ºC-10ºC~40ºC-
Ambient temperature40%~60%< 80%-
Signal waveformSine waveSine waveβ=0.01
Signal frequency50Hz±1Hz45Hz~65Hz-
Working voltage9V±0.1V9V±1.5V-
Current amplitude at measurement of phase frequency and sequence200mA±3mA2mA~20A-
Voltage amplitude at measurement of phase frequency and sequence100V±10V10V~600V-
Current amplitude of measurement of power and power factor200mA±3mA20mA~20A-
Voltage amplitude of measurement of power and power factor100V±10V10V~600V-
External electric field magnetic fieldShould be avoided
Position of test lead under testTest lead is near the geometric center of the clamp.

General specification
Power supplyDC9V Alkaline dry battery LR6(1.5V AA size 6pcs)
Measurement range
(fully automatic)
Voltage: AC 0.00V~600V
Current: AC 0.0mA~20.0A
Phase: 0.0°~360.0°
Frequency: 45.00Hz~65.00Hz
Active power: 0.0W~12kW
Reactive power: 0.0var~12kvar
Apparent power: 0.0VA~12kVA
Power factor: -1~+1
Clamp openingSharp mouth: Φ8mm
Round mouth: 35*40mm
ResolutionVoltage: AC 0.01V
Current: AC 0.1mA
Phase: 0.1°
Frequency: 0.01Hz
Active power: 0.1W
Reactive power: 0.1var
Apparent power: 0.1VA
Power factor: 0.001
Data storage1500 groups
CommunicationUSB port. Data is uploaded to PC via USB port for data analysis and management.
Working currentThe Max. power consumption is 135mA when the backlight is turned on, and the battery works continuously for about 6 hours.
Turn off the backlight and power consumption is 90mA. The battery works continuously for about 9 hours
Display2.8-inch TFT LCD color screen, display area 58*44mm
Size196*92*54mm
Detection rateAbout 2s/times
Data holdPress "HOLD" button during test and "HD" symbol appears.
Auto-shut-downAfter start-up for about 15 minutes, the meter automatically shuts down to reduce battery consumption.
BacklightAvailable. Applicable in the darkness and at night.
Backlight is turned off automatically after five minutes of no operation.
Voltage detectionWhen the battery voltage is lower than 7.2V, symbol is displayed to remind the replacement of the battery.
WeightMain unit: 550g (with battery)
Sharp-mouth current clamp: 170g×2
Round-mouth current clamp: 185g×2
Test lead: 250g
Test lead1.5m
Test lead of current clamp2m×φ5mm
Working condition-10ºC~40ºC; <80%RH
Storage condition-10ºC~60ºC; <70%RH
Input impedanceInput impedance of test voltage: 1MΩ
Withstand voltageWithstand voltage AC 1000V/50Hz (sine wave) between instrument line and shell for 1 minute.
Insulation Insulation between instrument line and shell ≥100MΩ
StructureDouble insulation, with shock-proof insulation sheath.
Standard complianceIEC61010-1 CAT III 600V, IEC61010-031, IEC61326, pollution degree 2


Basic error and index under reference condition
ItemMeasurement rangeResolutionBasic error
VoltageAC 0.00V~600V0.01V±(0.5%F.S.)
CurrentAC 0.0mA~20.0A0.1mA±(0.5%F.S.)
Phase0.0°~360°0.1°±1°
Active power (P)0.0W~12kW0.1W±(1.0%F.S.)
Reactive power (Q)0.0var~12kvar0.1var±(1.0%F.S.)
Apparent power (S)0.0VA~12kVA0.1VA±(1.0%F.S.)
Power factor (PF)-1~+10.001±0.03
Frequency (F)45Hz~65Hz0.01Hz±(1.0%F.S.)

Note: Phase error under working condition: ±3° within 10mA~20A; ±6° below 10mA

GDCR4000A Digital Double-clamp Phase Volt-ampere Meter
GDCR4000A Digital Double-clamp Phase Volt-ampere Meter
GDCR4000A Digital Double-clamp Phase Volt-ampere Meter
GDCR4000A Digital Double-clamp Phase Volt-ampere Meter