China Bante950-S Online Conductivity Meter Laboratory Equipment Seawater Salinity Resistivity, Find details about China Lab Equipment, pH TDS ORP Conductivity Meter from Bante950-S Online Conductivity Meter Laboratory Equipment Seawater Salinity Resistivity
The standard configuration
Con-1 conductivity electrode (range: 10 μs /cm~20mS/cm), temperature probe, conductivity standard solution (84 μs /cm, 1413 μs /cm, 12.88ms /cm), electrode stand and power adapter.
Optional conductivity electrode
CON - 0.1:
Suitable for measuring low conductivity liquid (<10 μs /cm), such as pure water.
CON - 10 type:
Suitable for measuring high conductivity liquids (>20mS/cm), such as seawater.
Model | Bante950 | |||
Conductivity | ||||
Range | 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm | |||
Accuracy | ±0.5% F.S | |||
Calibration Points | 1 to 5 points | |||
Calibration Solutions | 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm | |||
Temperature Compensation | 0~100°C, 32~212°F, Manual or Automatic | |||
Temperature Coefficient | 0.0~10.0%/°C | |||
Compensation Modes | Linear or Pure Water | |||
Cell Constant | K=0.1, 1, 10 or User-defined | |||
Normalization Temperature | 20°C or 25°C | |||
TDS | ||||
Range | 0~10ppt (Max. 20ppt, depending on factor setting) | |||
Accuracy | ±1% F.S | |||
TDS Factor | 0.1~1.0 (Default 0.5) | |||
Salinity | ||||
Range | 0~10ppt (Max. 80ppt) | |||
Accuracy | ±1% F.S | |||
Measurement Modes | Seawater or Practical Salinity | |||
Resistivity | ||||
Range | 0~100MΩ | |||
Accuracy | ±1% F.S | |||
Resolution | 0.01, 0.1, 1 | |||
Temperature | ||||
Range | 0~105°C, 32~221°F | |||
Accuracy | ±0.5°C, ±0.9°F | |||
Resolution | 0.1°C | |||
Calibration Points | 1 point | |||
Calibration Range | Measured value ±10°C | |||
Others | ||||
Hold Function | Manual or Automatic | |||
Stability Conditions | Low or High | |||
Calibration Due | 0 to 31 days | |||
Power Off | Manual or Automatic (10, 20, 30 minutes) | |||
Reset Function | Yes | |||
Memory | Stores up to 500 data sets | |||
Output | USB Communication Interface | |||
Connector | 6-pin Mini Plug | |||
Display | LCD (130×110mm) | |||
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz | |||
Dimensions | 210(L)×188(W)×60(H)mm | |||
Weight | 1.5kg | |||
Items | Description | |||
CON-0.1 Conductivity Electrode | For the pure water | |||
CON-1 Conductivity Electrode | For the general liquids | |||
CON-10 Conductivity Electrode | For the high conductivity liquids | |||
Conductivity Standard Solutions | 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm | |||
TP-10K Temperature Probe | Special-purpose sensor | |||
Order Code | Dimensions | Weight | ||
Bante950-S | 310(L)×240(W)×180(H)mm | 1.7kg | ||
Bante950-DL | 310(L)×240(W)×180(H)mm | 1.7kg | ||
Bante950-DH | 310(L)×240(W)×180(H)mm | 1.7kg | ||
Bante950-UK | 310(L)×240(W)×180(H)mm | 1.7kg |