China Ainuo Anevt 500V/800V/1000V DC Power Supply for Electric Vehicles, Fuel Cells, Motors, UPS/EPS Testing, Find details about China Bidirectional DC Power Source, Grid Feedback DC Power Supply from Ainuo Anevt 500V/800V/1000V DC Power Supply for Electric Vehicles, Fuel Cells, Motors, UPS/EPS Testing
ANEVT series dual-channel bidirectional DC power supply adopts high-frequency PWM rectification and bidirectional DCDC conversion, FPGA digital control, seamless switching between forward and reverse, automatic bidirectional operation, energy feedback to the grid at full power; advanced digital control, ultra-high control accuracy, fast response; two channels independently configured and not affect each other, which can be used in parallel to expand the DC output capacity and reduce investment by customer; abundant programming and testing functions, suitable for a variety of applications with different upper computer software.
Voltage level | Product model | Rated current per channel (A) | Peak current per channel (A) | Rated power per channel (kW) | Peak power per channel (kW) | Peak time (S) |
24-800V | ANEVT800-300DA | 300 | 450 | 90 | 135 | 60 |
ANEVT800-500DA | 500 | 700 | 160 | 224 | 60 | |
ANEVT800-600DA | 600 | 780 | 200 | 260 | 60 | |
ANEVT800-700DA | 700 | 800 | 250 | 286 | 60 | |
ANEVT800-750DA | 750 | 850 | 300 | 340 | 60 | |
ANEVT800-900DA | 900 | 1100 | 400 | 489 | 60 | |
ANEVT800-1000DA | 1000 | 1260 | 500 | 630 | 60 | |
24-1000V | ANEVT1000-200DA | 200 | 267 | 90 | 120 | 60 |
ANEVT1000-250DA | 250 | 375 | 160 | 240 | 60 | |
ANEVT1000-300DA | 300 | 390 | 200 | 260 | 60 | |
ANEVT1000-600DA | 600 | 780 | 250 | 325 | 60 | |
ANEVT1000-650DA | 650 | 850 | 300 | 392 | 60 | |
ANEVT1000-900DA | 900 | 1200 | 400 | 533 | 60 | |
ANEVT1000-1000DA | 1000 | 1260 | 500 | 630 | 60 | |
Description |
|
Voltage level | Product model | Rated current per channel (A) | Peak current per channel (A) | Rated power of the whole machine (kW)[J1] | Peak power per channel (kW) | Peak time (S) |
24-800V | ANEVT800-200DB | 200 | 300 | 90 | 68 | 60 |
ANEVT800-250DB | 250 | 370 | 160 | 118 | 60 | |
ANEVT800-300DB | 300 | 450 | 200 | 150 | 60 | |
ANEVT800-350DB | 350 | 450 | 250 | 161 | 60 | |
ANEVT800-400DB | 400 | 475 | 300 | 178 | 60 | |
ANEVT800-450DB | 450 | 675 | 400 | 300 | 60 | |
ANEVT800-600DB | 600 | 800 | 500 | 330 | 60 | |
24-1000V | ANEVT1000-250DB | 250 | 375 | 250 | 188 | 60 |
ANEVT1000-300DB | 300 | 390 | 300 | 195 | 60 | |
ANEVT1000-600DB | 600 | 800 | 400 | 267 | 60 | |
ANEVT1000-650DB | 650 | 850 | 500 | 327 | 60 |
General parameters of dual channel ANEVT(F) series | ||
Input parameters | Input Power | 4-phase 3-wire +PE, line voltage 380V±57V, 50/60Hz±5Hz |
Isolation function | Built-in isolation transformer | |
Input power factor | 0.99 (rated conditions) | |
Input current distortion | 5% (rated conditions) | |
Output parameters | Voltage accuracy | 0.05% F.S, resolution: 0.1V |
Current accuracy | 0.1% F.S, resolution: 0.1A | |
Power accuracy | 1% F.S, resolution: 10W | |
Power supply effect | Source effect: 0.1% F.S, load effect: 0.1% F.S | |
Ripple (Vpp) | 0.2%F.S | |
Transient recovery time | 5 ms | |
Current rise time | 10ms (10%~90%, resistive load, test condition: power output, load test on) | |
Protection | IGBT overheat, IGBT overcurrent, transformer overheat, input overvoltage, input undervoltage, output overvoltage, output overcurrent, lack phase protection | |
Three-phase line voltage | 323~437V (allowed grid voltage) | |
Feedback parameters | Frequency | 45~65 (allowed grid frequency) |
Power factor | 0.99 (rated conditions) | |
Total harmonic content | 5% (rated conditions) | |
Switching time | 10ms (forward maximum current to reverse maximum current) | |
Feedback function | Energy feedback at full power | |
Function | Wave editing | Control of voltage/current slope, ladder, cycle control, jump control |
E-stop | E-stop button | |
Battery simulation | With battery simulation function | |
Soft start | Pre-charge | |
Communication port | Standard Can port/RS232 port, optional RS485/LAN. | |
Output contactor | Available and controllable | |
Discharge protection | Discharge Unit protection unit | |
Fan speed control | Fan temperature control and speed regulation | |
Switch input interface | 3 channel | |
Switch output interface | One for each channel, indicating alarm status of the channel | |
Working environment | Temp./humidity | 0~40ºC, 10~90%RH (no condensation) |
Altitude | ≤2000m |