China IEC 60331-11 & 21 Fire-Resistant Property Test Equipment Wire and Cable, Find details about China Wire and Cable Tester, Fire Resistance Test Equipment from IEC 60331-11 & 21 Fire-Resistant Property Test Equipment Wire and Cable
Introduction:
Fire-resistant cable refers to the cable that can keep a safe running time in the case of flame combustion.
This Fire Resistance test equipment is designed according to the requirements of IEC60331-11,and used to obtain the refractory characteristics of a fire resistant cable or optical cable under flame conditions.
Standards
• IEC 60331 Part 11:Tests for electric cables under fire conditions - Circuit integrity - Part 11: Apparatus - Fire alone at a flame temperature of at least 750 degree C
• IEC 60331 Part 21:Specifies the test procedure and gives theperformance requirement, including a recommended flame application time, for cables of rated voltages up to and including 0,6/1,0 kV required to maintaincircuit integrity when subjected to fire under specified conditions
Main Features:
1, All fixtures of Wire and Cable Fire Resistance Characteristics Test Equipment are made of stainless steel;
2, The burner is a belt type propane blowtorch with a Venturi mixer, and the burner nozzle is length 500mm, width 15mm;
3, Those burning holes are staggered into 3 rows, and the front width is 15mm, holes diameter is 1.32mm and these holes center distance is 3.2mm;
5, One end of the specimen holder is equipped with a clamp to fix the sample, and the other end is convenient for heat transfer along the longitudinal specimen;
6, The cable sample is supported by two metal rings, and the middle length of the two rings is about 300mm;
7, An inner diameter of the sample supporting metal rings is 150mm, and the cross-sectional diameter of the ring is 10 ± 2mm.
8, The position of the burner torch from burning the bottom is not less than 200mm, and not less than 300mm from the tank wall.
Combustion System:
1, Independent standard electrical control platform;
2, With intelligent detection function, when a short circuit in the sample during the test, automatic alarm and turn off the fire source.
3, Fuse current in the experimental circuit is 2A;
4, The sample is applied to power of AV 100V ~ 1000V adjustable;
5, The time can be set free for the fire, the time recommended by standards is 90min.
Technical Specifications
1 | Power supply | AC 380V 3-phase, 50 / 60Hz, 30A |
2 | Overall dimension | 1,600 (W) × 850 (D) × 1,650 (H) mm |
3 | Console size | 600 (W) × 750 (D) × 1,200 (H) mm |
4 | Weight | 300KG |
5 | The input voltage | 0 ~ 1000V; can be adjusted |
6 | Maximum power | 5000VA |
7 | Timer | 0 ~ 999min |
8 | The flame temperature | 0 ~ 1100 ºC adjustable |
9 | The test load current | 0.25A, can be adjusted |