Clean Room Air Handling Unit, Ahu

China Clean Room Air Handling Unit, Ahu, Find details about China Floor Standing Type Ahu, Double Skin Panel Horizontal Ahu from Clean Room Air Handling Unit, Ahu

Model NO.
HJK02-HJK200
Origin
Beijing China
Model NO.
HJK02-HJK200
Origin
Beijing China
Clean Room Air Handling Unit, Ahu
1. AHU, Airflow 2799-51849m3/h
2. Energy Recovery section: Available, all systems-plate heat exchanger, rotary heat exchanger, or enthalpy wheel
3. Customized specifications

Working principle

1. Both supply fan and exhaust fan are built inside to bring in fresh air and exhaust out the stale indoor air as well, thus to keep indoor spaces in natural comfort;

2. Built-in heat exchanger(rotary heat exchanger or plate heat exchanger)transfers energy contained in the outgoing indoor air to the coming fresh air, thus fresh air is precoolid or preheated;
Clean Room Air Handling Unit, AhuClean Room Air Handling Unit, Ahu
3. Various functional sections such as filter section, cooing/heating section, humidifying section etc. Can be combined together to meet different air treatment requirements.

HOUSING CONSTRUCTION FEATURES

1. Frost resisting cold bridge design
Double-skin panel sandwiched with high density PU foam, thermal conductivity below 0.01999W/m Degree, insuring high performance between -40Degree and +70Degree.

2. High mechanical strength
Galvanized sheet inner skin, color steel sheet outer skin, strong steel framework, pressure endurance up to
2000PA, suitable for large air application.

3. High air impermeability
Double inlaid sealing to join the frameworks and panels tight, minimizing air leakage.

4. Flexible combination
Designed with 102mm modulus, frameworks and panels are flexible to change according to design requirements.
Clean Room Air Handling Unit, Ahu
No.Part NameMaterialDescription
1Unit panelexternal plate material is colorful steel sheet t0.4mm, specialized for air conditioningelegant apprearance, dignity, high corrosion resistance
inner plate material is galvanized steel sheet t0.5mmadopt spangle-free
2Panel heat preservationhigh pressure foamed polyurethane t 50mmgood insulation performance, high strength, foaming ratio 40Kg/m³
3Other heat preservationpolyethylene foaminggood insulation performance
4Unit framet 1.0mm  colorful steel sheet framecorrosion resistance, long product life,   high strength
5Copper tube of cooling coilØ 12.7mm copper tube,   wall thickness 0.41mmphosphorized seamless copper tube, good heat-transfer
 
6Cooling coil finØ 12.7mm copper tube, adopt aluminium foil t0.15mmaluminium foil surfact dealt with acrylic resin
7Cooling coil header/pipingseamless steel pipe, taper pipe weldedHVAC special pressureizated seamless steel pipe
8Drain panstainless steel,   ( cold-roll steel sheets spray treatment  t1.5mm, optional standard type)corrosion resistance, long product life, clean
9Rotary heat exchangersensible, 0.05mm heat exchang aluminum foilhigh efficient heat exchange, clean-self
10Primary filterG4 synthetic plate type, PVC framenon-woven
11Secondary filterF7 synthetic bag type, PVC framenon-woven
12Supply fan/Exaust fanBelt drive multi-blade anteverted centrifugal fanhigh-quality bearings, good performance, low noise
13DamperRubber dampergood elastictiy, good vibration reducing performance, low the noise
14Braid connection PVC coatingB1 flame-proof type
15Unit base C type steelsurface spraying treatment, high strength, high corrosion resistance
16Package form wood pallet, wrapping film 