12V9ah Lead Acid Replacement Battery for APC UPS

China 12V9ah Lead Acid Replacement Battery for APC UPS, Find details about China VRLA Battery, Storage Battery from 12V9ah Lead Acid Replacement Battery for APC UPS

Model NO.
SM12V9AH
Installation
Packaged
Rechargeable
Chargeable
Item Name
VRLA Lead Acid Storage Battery
Maintenance Type
Free
Size
151*65*94*100mm
Weight
2.45kg/PCS
Material
Fire Proof Case
Warranty
2 Years
Terminal
F1/F2
Working Temperate
-15 to 45
Certificate
Ce, UL.ISO.PV
Cell
6
Trademark
FGET
Transport Package
10PCS/CTN
Specification
12V9Ah /20 HR
Origin
Guangzhou, China
HS Code
85072000
Model NO.
SM12V9AH
Installation
Packaged
Rechargeable
Chargeable
Item Name
VRLA Lead Acid Storage Battery
Maintenance Type
Free
Size
151*65*94*100mm
Weight
2.45kg/PCS
Material
Fire Proof Case
Warranty
2 Years
Terminal
F1/F2
Working Temperate
-15 to 45
Certificate
Ce, UL.ISO.PV
Cell
6
Trademark
FGET
Transport Package
10PCS/CTN
Specification
12V9Ah /20 HR
Origin
Guangzhou, China
HS Code
85072000
Future Green 12V9AH Lead Acid Replacement Battery for APC UPS

Features:
1. Long battery life, high capacity, Superior of recovery after discharge.
2. ABS material: increase the strength of battery container.  (Flame-retardant ABS is optional)
3. High purity raw material: ensure low self discharge rate.
4. Absorbent Glass Mat(AGM) technology for efficient gas recombination of up to 99% and freedom from
electrolyte maintenance or water adding.
5. Silver- coated copper terminals, brass insert terminals and lead terminals improve the electric conductivity.
6. Pb CaSn alloy for plate grids: less gassing, less self-discharging high quality.
7. Maintenance-Free Operation
8. Low Self-Discharge


 
12V 9AH Battery Parameters:
 
1. Functional Parameter 5. Environment Temperature 
Nominal Voltage 12VDischarge Temperature -15~50ºC
Nominal Capacity (20 hour rate)9AhCharge Temperature 0~40ºC
Number of Cells 6cells Storage Temperature -15~40ºC
2. Rated Capacity at 25ºC (77° F)6. Inner Resistance & Max . Discharge Current 
20 hour rate (0.05C, 10.8V)9AhFully Charged battery at 25ºC (77° F)<18mΩ
5 hour rate (0.165C, 10.8V)8.05AhMax. Discharge Current (7 min) 27.0A
1 hour rate (0.55C, 10.5V)5.74AhShort Circuit Current (10 sec)  90.0A
3. Capacity affected by Temperature (20 hour rate)7. Self-discharge  at 25ºC (77° F)
40ºC   (104° F)103%Capacity after 3 month storage 91%
25ºC   (77° F)100%Capacity after 6 month storage82%
0ºC    (32° F)85%Capacity after 9 month storage73%
-15ºC   (5° F)65%Capacity after 12 month storage64%
4. Dimension and Weight 8. Constant voltage charging at 25ºC (77° F)
Length 151mmCyclic use14.4~14.9V
Width65mmMaximum charging current 2.70A
Height 94mmTemperature compensation -30mV/ºC
Total Height 100mmFloat use 13.6~13.8V
Reference Weight 2.55kgTemperature compensation -20mV/ºC
 12V9ah Lead Acid Replacement Battery for APC UPS
 
Battery Inside Structure:
 
12V9ah Lead Acid Replacement Battery for APC UPS

 
Lead Acid Battery Series:
 
ModelVoltageCapacity
(20h)
Size
(mm)
Plate
Number
Weight
(kg)
SJ6V4.5Ah6V4.5Ah70*47*101*107180.71
SJ6V7Ah6V7Ah151*34*94*100241
SJ6V10Ah6V10Ah151*50*94*100361.5
SJ12V1.3Ah12V1.3Ah97*43*51*57300.56
SJ12V4Ah12V4Ah90*70*101*107361.4
SJ12V7Ah12V7Ah151*65*94*100482
SJ12V9Ah12V9Ah151*65*94*100542.6
SJ12V12Ah12V12Ah151*98*95*101783.5
SJ12V17Ah12V17Ah181*77*167*167484.9
SJ12V24Ah12V24Ah177*165*126*126667.3
SJ12V30Ah12V30Ah177*165*126*126788.8
SM12V33Ah12V33Ah196*131*155*180429.2
SM12V36Ah12V36Ah196*131*155*1804210.6
SM12V38Ah12V38Ah196*165*175*1823611.4
SM12V42Ah12V42Ah196*165*1754212.8
SM12V45Ah12V45Ah196*165*1754213.2
SM12V55Ah12V55Ah229*138*208*2274815
SM12V65Ah12V65Ah350*166*1756619
SM12V70Ah12V70Ah350*166*1757221
SM12V80Ah12V80Ah350*166*1757822
SM12V100Ah12V100Ah307*168*208*2276628
SM12V120Ah12V120Ah406*174*208*2339033
SM12V120Ah12V120Ah406*174*222*2387834
SM12V134Ah12V134Ah340.5*173*280(285)6636
SM12V145Ah12V145Ah340.5*173*280(285)7840
SM12V150Ah12V150Ah483*170*241*24111443
SM12V180Ah12V180Ah532*207*215*24012652
SM12V200Ah12V200Ah522*240*219*24413859
SM12V210Ah12V210Ah522*240*219*22815061
SM12V260Ah12V260Ah522*240*219*22816269
Front Terminal Battery
SM12V55Ah-F12V55Ah-F277*106*222.5*222.56616
SM12V75Ah-F12V75Ah-F562*114*188*1887818
SM12V100Ah-F12V100Ah-F394*109*286*2866633
SM12V105Ah-F12V105Ah-F507*109*223*2386635
SM12V150Ah-F12V150Ah-F551*109*288*2886646
SM12V150Ah-F12V150Ah-F551*105*288*2886645
SM12V180Ah-F12V180Ah-F560*125*316*3167852
 
Battery Use and Maintenance:
1) Please use constant-voltage charge.
2) In floating charge, the voltage is 2.23 to 2.27 per unit cell.
3) In cycle use, the voltage is 2.35 to 2.45 per unit cell, the max. Current is no more than 25%° C
4) Please do tighten the bolts to avoid sparkle and poor contact when the battery is in use.
5) Please do not use it near the heat source and open flame.
6) Please keep it at low temperature. Please change it while there is liquid leaking or damage.

Factory Show: 

12V9ah Lead Acid Replacement Battery for APC UPS


 
Packing Details:
 

12V9ah Lead Acid Replacement Battery for APC UPS

Our Services:

 Samples and OEM, Warranty and After-Sale Service: 
 
  •  Sample can be provided for quality testing
  •  OEM Welcomed
  •  Warranty: 2 Year
  •  After-Sale Service: 24 Hour-Hot Line for Consultacncy and Technical Support
Our Qualification:

12V9ah Lead Acid Replacement Battery for APC UPS


 
Payment Terms:
 Payment TermsT/TEXW30% T/T in advance, paid the balance before shipment
FOB
CFR(C&F)30% T/T in advance, paid the balance against copy of B/L
CIF
L/CL/C amount above 50,000 usd, we can accept L/C at sight
West UnionAmount lower than 5000usd
Paypal
  Delivery time15 working days after receiving payment for one container
  
FAQ:
Q1: How to choose a right battery?
A1:Tell us your demand, then our sales will recommend a suitable battery to you. 
Q2: How about the delivery time?
A2:  7 days for sample; 15 days for bulk order.
Q3: What is the warranty of lead acid battery?
A3: 5 years warranty on FGET-Solar product.
Q4: How to solve the technical problem?
A4: 24 hours after-service consultancy just for you and to make your problem to solve easily.

Q5: How To Ask for support if products failure in warranty?
A5: 1. Email us about PI number, serial number,Product S/N number,  show us more details such as: pictures, your testing report or video, if it is the quality problem of product itself, we will resend a new one in next order. 2. we will submit your case to our after sales department, and solve it in 24 hours.