Dairy Farm Milk Cooling Water Cooled Chiller
Characteristics29 sizes available ranging from 130kW to 2500kW cooling capacity.
Acting as multi-function unit such as cooling, heating, sanitary hot water separately or simultaneously.
Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.
Semi- hermetic screw compressor for the whole range. Each compressor is equipped with a crankcase heater and a built-in electronic protection with temperature sensor located directly in the motor winding and on the discharge line.
The refrigerant circuit is complete with sight glass, filter drier, high and low pressure gauges, solenoid valve, electronic expansion valve, high and low pressure switch.
Shell and tube dry expansion type condenser, factory insulated with flexible close cell material.
Shell and tube evaporator, higher efficiency less water consumption, easy maintenance and cleaning, factory insulated with flexible close cell material. The electric panel consists of compressor breaker, compressor contactor, phase sequence relay, control circuit breaker, microprocessor control with function display.
LCD display, touch screen control panel as standard.
Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.
An infinitely variable capacity control system that is capable of exactly matching the demand requirement of the system is to be supplied. This system is to provide precise and stable control of supply water temperature over the complete range of operating conditions.
OptionalDesuperheater as optional.
Electronic controller with BMS system.
Technical DataModel | Unit | WW130 | WW170 | WW200 | WW240 | WW260 | WW280 | WW310 | WW360 | WW380 | WW420 |
Cooling capacity* | Kw | 130 | 170 | 200 | 240 | 260 | 280 | 310 | 360 | 380 | 420 |
Power supply | 380-415V/3Ph/50Hz |
Compressor |
Qty/refrigerant circuit | Nr. | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 |
Cooling power input* | kW | 26 | 33 | 39 | 47 | 51 | 55 | 61 | 71 | 75 | 83 |
Energy adjustment steps | step | 25%-100% |
Max.current for writing | A | 69 | 87 | 108 | 128 | 154 | 158 | 161 | 165 | 175 | 185 |
Refrigerant charge | kg | 32 | 39 | 46 | 55 | 60 | 64 | 68 | 85 | 100 | 107 |
Evaporator |
Water side pressure drop | kPa | 42 | 45 | 45 | 45 | 45 | 46 | 46 | 46 | 47 | 46 |
Pipe size | mm | DN65 | DN80 | DN100 | DN100 | DN100 | DN100 | DN100 | DN125 | DN125 | DN125 |
Water flow rate in cooling* | m3/h | 22 | 29 | 34 | 41 | 45 | 48 | 53 | 62 | 65 | 72 |
Condenser |
Water side pressure drop | kPa | 42 | 45 | 44 | 44 | 45 | 45 | 44 | 44 | 44 | 42 |
Pipe size | mm | DN65 | DN80 | DN100 | DN100 | DN100 | DN100 | DN100 | DN125 | DN125 | DN125 |
Water flow rate in cooling* | m3/h | 27 | 35 | 41 | 49 | 54 | 58 | 64 | 74 | 78 | 86 |
Dimensions |
Length | mm | 2685 | 2720 | 2660 | 2880 | 2870 | 3170 | 3270 | 3170 | 3180 | 3180 |
Width | mm | 1090 | 1115 | 1175 | 1125 | 1125 | 1125 | 1230 | 1200 | 1285 | 1285 |
Height | mm | 1625 | 1555 | 1650 | 1645 | 1685 | 1685 | 1685 | 1685 | 1805 | 1805 |
Net weight | kg | 1600 | 1800 | 1900 | 2000 | 2100 | 2200 | 2250 | 2400 | 3000 | 3100 |
Noise level** | dB(A) | 68 | 69 | 69 | 70 | 70 | 72 | 73 | 73 | 73 | 73 |
Model | Unit | WW480 | WW530 | WW610 | WW680 | WW710 | WW760 | WW860 | WW960 | WW1000 | WW1120 |
Cooling capacity* | kW | 480 | 530 | 610 | 680 | 710 | 760 | 860 | 960 | 1000 | 1120 |
Ton | 137.1 | 151.4 | 174.3 | 194.3 | 202.9 | 217.1 | 245.7 | 274.3 | 285.7 | 320 |
Power supply | 380-415V/3Ph/50Hz |
Compressor | |
Qty/refrigerant circuit | Nr. | 1/1 | 1/1 | 1/1 | 1/1 | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 |
Cooling power input* | kW | 94 | 104 | 120 | 134 | 140 | 150 | 169 | 189 | 197 | 220 |
Energy adjustment steps | step | 25% - 100% | 12.5% - 100% |
Max. current for wiring | A | 258 | 292 | 302 | 335 | 2×165 | 2×175 | 2×175 | 2×185 | 2×246 | 2×258 |
Refrigerant charge | kg | 126 | 142 | 160 | 167 | 171 | 199 | 210 | 220 | 242 | 261 |
Evaporator | |
Water side pressure drop | kPa | 46 | 46 | 46 | 47 | 47 | 46 | 47 | 46 | 46 | 46 |
Pipe size | mm | DN125 | DN125 | DN125 | DN150 | DN150 | DN150 | DN150 | DN200 | DN200 | DN200 |
Water flow rate in cooling* | m3/h | 83 | 91 | 105 | 117 | 122 | 131 | 148 | 165 | 172 | 193 |
Condenser | |
Water side pressure drop | kPa | 42 | 42 | 44 | 42 | 44 | 42 | 44 | 42 | 44 | 44 |
Pipe size | mm | DN125 | DN125 | DN125 | DN150 | 2×DN125 | 2×DN125 | 2×DN125 | 2×DN125 | 2×DN125 | 2×DN150 |
Water flow rate in cooling* | m3/h | 99 | 109 | 126 | 140 | 146 | 156 | 177 | 198 | 206 | 231 |
Dimensions | |
Length | mm | 3505 | 3505 | 3505 | 3520 | 4060 | 4505 | 4505 | 4505 | 4660 | 4660 |
Width | mm | 1280 | 1315 | 1375 | 1380 | 1415 | 1415 | 1415 | 1415 | 1460 | 1460 |
Height | mm | 1970 | 1990 | 1980 | 1980 | 1975 | 2000 | 2000 | 2000 | 2090 | 2090 |
Net weight | kg | 3500 | 3800 | 4000 | 4100 | 4210 | 4400 | 4740 | 5600 | 6600 | 6800 |
Noise level** | dB(A) | 74 | 74 | 74 | 73 | 74 | 74 | 74 | 74 | 74 | 74 |
Model | Unit | WW 1200 | WW1250 | WW1360 | WW1470 | WW1720 | WW1840 | WW2000 | WW2350 | WW2500 |
Cooling capacity* | kW | 1200 | 1250 | 1360 | 1470 | 1720 | 1840 | 2000 | 2350 | 2500 |
Ton | 342.9 | 357.1 | 388.6 | 420 | 491.4 | 525.7 | 571.4 | 671.4 | 714.3 |
Power supply | 380-415V/3Ph/50Hz |
Compressor | |
Qty/refrigerant circuit | Nr. | 2/2 | 2/2 | 2/2 | 4/4 | 4/4 | 4/4 | 4/4 | 4/4 | 4/4 |
Cooling power input* | kW | 236 | 246 | 268 | 289 | 339 | 362 | 394 | 463 | 492 |
Energy adjustment steps | step | 12.5% - 100% | 6.25% - 100% |
Max. current for wiring | A | 2×292 | 2×302 | 2×315 | 4×175 | 4×185 | 4×246 | 4×258 | 4×258 | 4×292 |
Refrigerant charge | kg | 295 | 302 | 327 | 338 | 393 | 430 | 453 | 494 | 537 |
Evaporator | |
Water side pressure drop | kPa | 46 | 46 | 46 | 45 | 45 | 46 | 46 | 47 | 47 |
Pipe size | mm | DN200 | DN200 | DN200 | 2×DN150 | 2×DN150 | 2×DN200 | 2×DN200 | 2×DN200 | 2×DN200 |
Water flow rate in cooling* | m3/h | 206 | 215 | 234 | 253 | 296 | 316 | 344 | 404 | 430 |
Condenser | |
Water side pressure drop | kPa | 44 | 42 | 45 | 52 | 52 | 52 | 52 | 52 | 52 |
Pipe size | mm | 2×DN150 | 2×DN150 | 2×DN150 | 2×DN200 | 2×DN200 | 2×DN200 | 2×DN200 | 2×DN200 | 2×DN200 |
Water flow rate in cooling* | m3/h | 247 | 257 | 280 | 303 | 354 | 379 | 412 | 484 | 515 |
Dimensions | |
Length | mm | 4660 | 4660 | 4660 | 4600 | 4650 | 4690 | 4600 | 4780 | 4800 |
Width | mm | 1585 | 1585 | 1585 | 2250 | 2270 | 2300 | 2450 | 2450 | 2450 |
Height | mm | 2215 | 2215 | 2240 | 2350 | 2380 | 2410 | 2460 | 2470 | 2500 |
Net weight | kg | 7000 | 7400 | 8000 | 8800 | 9000 | 9800 | 11600 | 12300 | 13000 |
Noise level** | dB(A) | 74 | 74 | 75 | 76 | 80 | 80 | 81 | 81 | 81 |
* Performance values refer to the following conditions:
Condenser water inlet/outlet temperature: 30ºC/35ºC, evaporator water inlet/outlet temperature: 12ºC/7ºC.
** Noise level measured in free field condition at distance of 1 meter.