Portable Single Phase Kwh Meter Testing Set with Power Source

China Portable Single Phase Kwh Meter Testing Set with Power Source, Find details about China Multifunction Reference Standard Meter, Reference Standard from Portable Single Phase Kwh Meter Testing Set with Power Source

Model NO.
GF102
Power of The Voltage Output
Max. 30va, 15va
Resolution
0.01%
Accuracy
0.1%, 0.2%
Stability
0.02%/120s, 0.05%/120s
Distortion Factor
< 0.3% for Linear Resistance Load
Test Current Output
1mA~120A, 1mA~60A
Power of The Current Output
Max. 100va, 30va
Range
0 -- 360°
Input Frequency
Max. 20Hz
Trademark
GFUVE
Transport Package
Aluminium Alloy Box
Specification
CE, ISO9001: 2008, IEC
Origin
Beijing, China
HS Code
9030849000
Model NO.
GF102
Power of The Voltage Output
Max. 30va, 15va
Resolution
0.01%
Accuracy
0.1%, 0.2%
Stability
0.02%/120s, 0.05%/120s
Distortion Factor
< 0.3% for Linear Resistance Load
Test Current Output
1mA~120A, 1mA~60A
Power of The Current Output
Max. 100va, 30va
Range
0 -- 360°
Input Frequency
Max. 20Hz
Trademark
GFUVE
Transport Package
Aluminium Alloy Box
Specification
CE, ISO9001: 2008, IEC
Origin
Beijing, China
HS Code
9030849000
GF102 Portable Single Phase Kwh Meter Testing Set with Power Source
Portable Single Phase Kwh Meter Testing Set with Power SourcePortable Single Phase Kwh Meter Testing Set with Power SourcePortable Single Phase Kwh Meter Testing Set with Power Source
GF102 single phase energy meter testing set used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology. High voltage and current output. Widely used in lab and field.
Features
Meter under testing: 1P2W
Testing mode: Active power, reactive power
Test 3PCS or 2PCS meter synchronously
Starting test and creeping test
Reference standard and power source integrated, easy to carry.
Measuring mechanical meter and electric meter
Operating by manual keyboard or PC
With shortcut key of normal test point, speed up testing
Internal large capacity storage device for mass memory
Local checking the testing result
Overload, short circuit, open circuit protection
With self-checking function
Technical Data
Voltage
Test voltage output (Phase-Neutral)0V~264V
Power of the voltage outputMax. 30VA, 15VA
Resolution0.01%
Accuracy0.1%, 0.2%
Stability0.02%/120s, 0.05%/120s
Distortion factor< 0.3% for linear resistance load
Current
Test current output1mA~120A, 1mA~60A
Power of the current outputMax. 100VA, 30VA
Resolution0.01%
Accuracy0.1%, 0.2%
Stability0.02%/120s
Distortion factor< 0.3% for linear resistance load
Phase angle
Range0 -- 360°
Resolution0.1°
Accuracy0.2°
Frequency
Range45Hz~65Hz
Resolution0.005Hz
Pulse output
High frequency output(CH)1.666× 105 Hz
Low frequency output(CL)5× 10-5× CH
Pulse input
Input channel3
Input frequencyMax. 20Hz
Other
Voltage Supply220V± 10% 50/60Hz± 2Hz
Ambient temperature-10° C -- +40° C
Relative humidity35% -- 85%