Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels

China Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels, Find details about China Air Heat Pump, Air Source Heatpump from Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels

Model NO.
KMAT Series
Origin
China
HS Code
8414809090
Model NO.
KMAT Series
Origin
China
HS Code
8414809090
Package size per unit product
6000.00cm * 2000.00cm * 3000.00cm
Gross weight per unit product
5000.000kg
Heat Pump Air to Water Converter with Europe Energy Labels

Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels



Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels
Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels
Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels
Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels
ProjectUnitR134a UnitsR22 Units
Environmental sideDry bulb temperatureºC  -35-21ºC  -35-21ºC
Use side Water outlet temperatureºC  35-70ºC  35-55ºC
Water flowm3/hRated Flow±15%Rated Flow±15%
Allowable voltage rangeVRated voltage±5%Rated voltage±5%
Three-phase voltage imbalance rate/±2%±2%
 Allowable frequency rangeHZRated frequency±2%Rated frequency±2%
Note if water outlet temperature is higher than 70ºC
 
ModelKMAD-100KMAT-150KMAT-200KMAT-240KMAT-280KMAT-330
The refrigerantR134a
HeatingKW100150200240280330
Input power
(rated condition)
KW38557085100113
power supply 3φ-380V-50HZ
protective deviceReverse phase loss protection, over current protection,
motor temperature protection, high and low voltage protection,
high and low temperature protection, water flow protection
Refrigeration circuit1
Energy control (%)0,50,75,100
Refrigerant charge (kg)100150160180200220
Finned heat exchangerCopper tube wearing hydrophilic corrugated aluminum sheet
FanFormAxial Flow
Flow (m3/h)60000600009000090000120000120000
Power (kw)66991212
Water side maximum pressure MPaFormShell and tube heat exchanger
Water side maximum pressure MPa1
 Import and export pipe diameterDN65DN80DN100DN100DN125DN125
Hot water flow17.225.834.441.34956.8
Water pressure drop384245485255
Running noisedB(A)757778808182
Unit length(mm)336033605000500060006000
Unit width(mm)226022602230223022302230
Unit height(mm)250025002500250025002500
Unit weight(kg)400043006400670081008500
Running weight(kg)450048007000730087009200
1. According to GB/T 25127.1-2010, the nominal heating standard: ambient dry bulb temperature -12°C,
ambient wet bulb temperature -14°C, hot water outlet temperature 41°C, water flow 0.172 m3 / h * kW;
2, The ambient temperature range: -25 ° C ~ 21 ° C; Tot water temperature range: 35°C ~ 70°C;
3. The unit parameters are subject to change without prior notice. The specific parameters are subject to the product nameplate;
4. KMAD-100 unit is a heating and cooling unit, GB/T 25127.1-2010 national standard nominal cooling capacity is
5.  for the upcoming product model.
 
ModelKMAT-130A*KMAT-190A*KMAT-290A*KMAT-350AKMAT-350AV
The refrigerantR22
HeatingKW130190290350350
Input power
(rated condition)
KW456598118120
power supply 3φ-380V-50HZ
protective deviceReverse phase loss protection, over current protection,
motor temperature protection, high and low voltage protection,
high and low temperature protection, water flow protection
Refrigeration circuit1
Energy control (%)0,50,75,100
Refrigerant charge (kg)160180200220220
Finned heat exchangerCopper tube wearing hydrophilic corrugated aluminum sheet
FanFormAxial Flow
Flow (m3/h)6000090000120000120000120000
Power (kw)69121212
Water side maximum pressure MPaFormShell and tube heat exchanger
Water side maximum pressure MPa1
 Import and export pipe diameterDN80DN100DN125DN125DN125
Hot water flow22.432.74960.260.2
Water pressure drop4548525555
Running noisedB(A)8080828585
Unit length(mm)35005000600060006000
Unit width(mm)22302230223022302230
Unit height(mm)25002500250025002500
Unit weight(kg)45006200800085008500
Running weight(kg)50006700870090009000
1. According to GB/T 25127.1-2010, the nominal heating standard: ambient dry bulb temperature -12°C,
ambient wet bulb temperature -14°C, hot water outlet temperature 41°C, water flow 0.172 m3/h*kW;
2. The ambient temperature range: -35°C ~21°C; Tot water temperature range: 35°C ~55°C;
3. The unit parameters are subject to change without prior notice. The specific parameters are subject to the product nameplate.
4.  for the upcoming product model.
 

FAQ

Q1: Are you factory or trade company?  
A1: We are factory.

Q2: What the exactly address of your factory? 
A2: No. 366, YangzhuangBang Street, Pingxing Rd., Xindai Town, Pinghu, Zhejiang Province, China

Q3: Warranty terms of your machine? 
A3: Two years warranty for the machine and technical support according to your needs.

Q4: Will you provide some spare parts of the machines? 
A4: Yes, of course.

Q5: How long will you take to arrange production? 
A5: 380V 50HZ we can delivery the goods within 10 days. Other electricity or other color we will delivery within 22 days

Q6: Can you accept OEM orders? 
A6: Yes, with professional design team, OEM orders are highly welcome.

DENAIR Factory
Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels




DENAIR Exhibition
Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels





DENAIR Customer Case:

Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels



DENAIR Packing & Shipping

Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels