China 1250kVA Load Bank for Rl Diesel Generator Loading Test, Find details about China 1250kVA Load Bank, Generator Loading Test from 1250kVA Load Bank for Rl Diesel Generator Loading Test
1250KVA Load Bank for RL Diesel Generator Loading Test
1.Product Introduction
1250KVA Load Bank for RL Diesel Generator Loading Test
It is composed of outdoor resistor-inductance AC load bank,data collection
system,electric control module,thermal module,control part etc.It can accurately detect Marine generator output power
and load capacity,and assist shipyard in acceptance of vessel,mooring test,sea trial,load test,static voltage characteristic
test, speed characteristic test,overload protection test,reverse power and reverse current protection test,and parallel
operation test etc.
2.1250KVA Load Bank for RL Diesel Generator Loading Test System Chart
3.1250KVA Load Bank for RL Diesel Generator Loading Test Working Environment
Altitute:≤2500m
Temperature:-10°C~50°C
Humidity:≤95%RH
Working Mode:Continuous work(>6hours continuous long-term work per day)
4.1250KVA Load Bank for RL Diesel Generator Loading Test Technical Specifications
Technical parameter | |
AC400-1250KVA-RL | |
Rated voltage /Frequency | AC Three-phase three-wire 400V,50Hz;AC three-phase four-wire 690V,50Hz |
Rated Capacity | 1250KVA |
Load Distribution | 2 load Resistive load:1100KW,Inductive load:825KVA |
Stepping Value | Resistive load: 50KW Inductive load: 50Kvar |
Resistor divider file | 50-1100KW adjustable |
Reactance file | 50-825Kvar adjustable |
Power factor | 0.8 |
Load Tolerance(each step) | ±5% |
Load Tolerance(overall) | ±3% |
Display Precision | 0.5 class |
Control Power Supply | External AC three phase connection 380V/50Hz |
Wire Connection | Load power supply input--Copper bar (star coupling) Control power supply input--Connector-bar |
Insulation grade | F class |
Duty cycle | Continuous |
Cooling | Forced air cooling, Horizontal inlet air, Vertical cooling |
Transportation | Hoisting, there are lifting lug in top of casing and casters in bottom of load bank |
Casing Color | Grey(RAL7035) |
Dimension | Resistive Load:1600*2400*2100mm Inductive Load:1200*2000*1800mm |
Weight | Resistive Load:1200Kg Inductive Load:2500Kg |
Operating Environment Parameter | |
Ambient Temperature | -10ºC~+50ºC |
Relative Humidity | ≤95% |
Altitude | ≤2500 meters |
Atmospheric Pressure | 86~106kPa |
Main components brand | |
Contactor | Schneider |
Circuit Breaker | Siemens |
Fuse | Delixi |
SCM | Infineon |
Alloy Resistor | Kaixiang |
Data Management Software | Kaixiang |
5.1250KVA Load Bank for RL Diesel Generator Loading Test Product Display
Overall Apperance
When you send inquiry or put orders, please provide information as more as possible, so that we can serve better.
1.Load voltage type: 1).AC 2).DC 3).AC&DC dual-use
2.Load wiring type: 1).1-phase 2).3-phase 3-wire 3).3-phase 4-wire 4).Other(please specify).
3.Load voltage: Low voltage 200V, 380V, 400V, 440V, 690V, 900V; High voltage 1.2kV, 3.3kV, 6.6kV, 10.5kV, 13kV, 35kV, 80kV.
4.Load frequency: 50Hz, 60Hz, 400Hz, 1000Hz, 2000Hz.
5.Load power, power factor, installed capacity(include active power and reactive power).
6.Working power or control power.
7.Environment for the installation and use: 1).Indoor 2).Outdoor 3).Dock 4).Offshore 5).Plateau
8.Load step setting requirements.
9.Control mode, select according to your request: 1).Local control 2).PC intelligent control 3).Remote Control (Control box, Control console, Control cabinet)
10.Display mode: select according to your request: 1).LED voltage voltmeter, current meter 2).LED multi function digital meter 3).Generator set tester.