Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System

China Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System, Find details about China Air Handling Unit, Chiller Air Handling from Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System

Model NO.
EST35MU4
Mounting
Floor Standing
Lifetime
>20 years
Certification
ISO, CE
Condition
New
Ahu Construction
25mm/ 50mm/ 75mm Double Skin
Optional 2
Heat Recovery Wheel
Control
Option for PLC, Ddc
Ahu Panels
Painted Steel, Gi, Ss Panels
Filters
Pre-Filter, Bag Filter, HEPA Filter
Cold Bridge Free Design
Yes
Base
C-Channel Hot DIP Base
Ahu Framework
Aluminum
Side Sliding Filter with Tracks
Yes
Cooling/ Heating Coil 2
Copper Tube with Copper Fins (Cu/Cu), Gi/SUS Frame
Cooling/ Heating Coil 1
Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr
Optional 1
VSD, VFD
Fan
Belt Drive Centrifugal Fan, Plug Fan, Ec Fan
PU Foam Insulation
43-48kg/M3
Optional 3
Ep, Chemical Filter, Plasma Sterilizer, Ak
Trademark
ESACIR
Transport Package
Standard Package
Specification
CE
Origin
Guangdong, China
HS Code
8415830000
Model NO.
EST35MU4
Mounting
Floor Standing
Lifetime
>20 years
Certification
ISO, CE
Condition
New
Ahu Construction
25mm/ 50mm/ 75mm Double Skin
Optional 2
Heat Recovery Wheel
Control
Option for PLC, Ddc
Ahu Panels
Painted Steel, Gi, Ss Panels
Filters
Pre-Filter, Bag Filter, HEPA Filter
Cold Bridge Free Design
Yes
Base
C-Channel Hot DIP Base
Ahu Framework
Aluminum
Side Sliding Filter with Tracks
Yes
Cooling/ Heating Coil 2
Copper Tube with Copper Fins (Cu/Cu), Gi/SUS Frame
Cooling/ Heating Coil 1
Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr
Optional 1
VSD, VFD
Fan
Belt Drive Centrifugal Fan, Plug Fan, Ec Fan
PU Foam Insulation
43-48kg/M3
Optional 3
Ep, Chemical Filter, Plasma Sterilizer, Ak
Trademark
ESACIR
Transport Package
Standard Package
Specification
CE
Origin
Guangdong, China
HS Code
8415830000
1.Eurostars air handling unit and air handler features
• Large air flow, high supply air static pressure and cooling capacity
• High efficiency purification, G4+F8+HEPA filters
• Multi-circuits refrigerating system for part load energy saving
• Large and high level condenser coil design to increase operation efficiency and energy saving
• High quality major components including electrical, compressor, fans ensure outstanding reliability and performance
• Easy and clear Microprocessor control panel with all operating data display
• Green environmental Heat Wheel option available configured flexibly, numerous options for customization


2.Eurostars Air handler,air handling unit, ahu application
The definition of air handling unit consisting of a fan or fans and other necessary equipment to perform one or more of the functions of circulating, cleaning, heating, cooling, humidifying, dehumidifying and mixing of air...."
The AHU is used to control the following parameters of the space.
---Temperature
---Humidity
---Air Movement
---Air Cleanliness


3.Air handler technical data, Assembly drawing diagram and photo
Modular Air Handling Unit
Model
EST
4R4MU46MU49MU412MU415MU418MU422MU425MU430MU435MU440MU445MU450MU4
6R4MU66MU69MU612MU615MU618MU622MU625MU630MU635MU640MU645MU650MU6
Air Flow*1000CMH46912151822253035404550
Cooling
Coil Section
Sensible Capa.
(KW)/4R
26405876102121131174201235274308348
Sensible Capa.
(KW)/6R
32497794122146185218258302349383433
Heating SectionE-Heating Capa.
(KW)
1218303645546072729090108108
Humidifying SectionHumidifying
Capa.(Kg/h)
5101315152530454560606075
Fan-motor
Section
ESP(Pa)600600600600600600800800800800800800800
Motor Power(KW)2.245.57.51111151518.518.5223030
Mixing Section
Pre-filter Section
Cooling Coil Section
Eliminator Section
Elec-heating Section
Humidifying Section
Fan-motor Section
Diffusing Section
Medium-filter Section
Supply Air Section
NOTE:
  1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC;
  2. Technical parameters are subject to be revised without prior notice.
Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System
4.Eurostars air handling unit , air handler range or series
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modular Modulus Air Handling Unit-multi-function air handling unit
Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System
5.Components-air handling unit or air handler

Casing Panel and Insulation
• Double skin construction is provided by sandwich type panels comprising inner and outer painted steel skins and polyurethane foam with minimum 48kg/m3 density, providing a good thermal and acoustical performance
• The gasket liner between the panels and frame ensures the air leakage rate to comply with GB/T 14294 clean air conditioning requirement
• The factory painted steel sheet covered with 6 insulation coatings, complies to 500h salt spray testing, showing an excellent corrosion protection performance

Frame
•Penta-post extra heavy gauge aluminum profiles and strong fiber-reinforced PE corner connection forming the structural  frame
• superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation
• Thermal bridge free design, the profiles filled with polyurethane foam for insulation
• Anodizing surface treatment for profiles, corrosion-resistant
• Stainless steel frame available

Sight Glass Service Door
• Double skin structure, inner panel is made of stainless steel, and outer panel is made of painted steel sheet
• Positive and negative access door, ensures the airtight of unit
• Convenient to check the running status of the unit
• Double sealing, no air leakage
• Built-in multi-point fastening locks make the panel evenly stressed, preventing air leakage and loss of energy efficiency of the unit

Hot-Dip Galvanized Base channel
Offer Rigid Base Channel protect unit and save installation cost

Fan and motor
•NICOTRA centrifugal Fan or other brand fan;
•Double inlet
•Electric motor driven
•Back curved or front curved
•low noise, high efficiency, stable operation, low vibration, good strength, low bearing temperature rise, and wide working temperature and humidity range.
•Customized configuration of the motor selected high-quality brand-name motor, smooth operation, low noise, long service life, and can be equipped with a specified brand of motor or motor insulation, protection level people according to user requirements, to meet the needs of different occasions.
•EC Fan is optional
• plug fan is optional
Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System

Vibration Eliminator
• To reduce the transmission of vibration and noise, fan and motor are installed on an independent complete base frame
• The complete base frame is isolated by deflection type spring isolators
• This unique structure not only reduce the vibration and noise, but also protect fan and motor during transportation

Cooling Coil
Cooling Coil is used to cool and dehumidify the air.Both DX (direct expansion) cooling and CW (chilled water) cooling coils are available for use depending on the system design.
These coils are arranged in rows with different fin spacing.Aluminum fins and copper tubes are used in the design of the coils.The corrosion resistance hydrophilic fins are also
used due to its lower cost and lower resistance to the air velocity.
Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System
PTC Electric Heating
•Constant temperature heating
•Virtually unlimited life
•Low electricity consumption and very low in cost
•No electrical noise
•The higher the temperature, the more electricity efficient
•Avoid burning when in contact with combustible materials
Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System
Electrostatic Precipitator(optional)
• Adsorb and remove particles less than 0.01 micron in the air
• Improve indoor air quality 
• ESP applies energy only to the particulate matter being collected and therefore is very efficient in its consumption of energy

Humidifier option
The humidifier often be used have: electrode humidifier, dry steam humidifier, high pressure spray humidifier and wet film humidifier etc
a)Electrode humidifier
Isothermality humidification type, use AC electricity can direct heating water supply to produce clean vapour and mix vapour with the air, add-wet into the air. the advantage is humidifying fast, humidifying volume can adjustable, humidifying vapour is clean, no incrustation scale,no dust, sterile and odourless, convenient to maintenance.

•Cylinder monitor system ensures more efficiency, better energy saving and stable result
•Drainage pump ensures the humidifying process accurate and stable
•Clog protection system ensures to avoid water overflow
•Water temperature control system makes sure the drainage pipe won't be damaged by hot water
•Anti-electric leakage system makes operation and maintenance safe and secure

b) Dry vapour humidifier
Isothermality humidification type, high humidification efficiency, corrosion resistance, in place have vapour source,dry vapour humidification will have a higher humidification control precision

c) High pressure spray humidifier
Isenthalpic humidification process,use stainless water distributor and sprayer,high pressure spray,high energy efficiency,safe and reliable.high pressure spray humidifier humidification efficiency 40%~50%.

d) Wet film humidifier
Wet film humidifier have advantage of high saturation efficiency,save water,save energy etc


Electrode Humidifier
Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System
Filters

Air filter include primary air filter, medium efficiency air filter, high effect and sub-high efficiency particulate air filter.
a) Primary filter have board type and pocket type, board type air filter use fiber materials, pocket type primary air filter use Non-woven or special chemical fiber, have the advantage of washable, low resistance, stable performance etc, filter grade G1~G4.
b) Medium efficiency air filter have board type and pocket type, use ultra-thin chemical fiber or fiber glass, have the advantage of long service-life, stable performance, filter grade F5~F8
c) High efficiency and Sub-high efficiency particulate air filter use ultra-thin chemical fiber or fiber glass, have dense folded type and pocket type for choose, filter grade can reach up to H13.
Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System

Differential pressure meter Brand name:PRECISE
Differential pressure meter( with signal transfer) can be configured acccording to user requirements. 

Air damper
•Variable discharge air volume
•Discharge damper with axial fan, independent control
•High efficiency
•Manual damper available
Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System
Heat Wheel Heat Exchanger(optional)
• Highly efficient energy-saving rotary heat exchanger
• Energy recovery rates between 70-90%
• Summer application is dehumidification of warm and humid supply air to reduce the energy consumption of the down stream cooling equipment. 
• Winter operation recovers moisture from the exhaust air to reduce the humidification load.

Stainless Steel Drain Pan
• Slop type design, no drain water carryover and keep the pan dry
• Avoid the micro-organisms growth inside the drain pan
Antimicrobial Drain Pan is offered as option
• SteriTouch technology Drip Pan Coating
• Antimicrobial surface
• Good exterior durability and corrosion resistance
• Excellent adhesion
• Non-toxic, comply with BS476 part 7

Electrical control cabinet(optioanl)
•According to the requirements and functions of the unit to design the control console or cabinet
•Auto control each section of the unit to make sure the temperature, humidity and cleaness
•High quality and international brand electrical elements
•DDC and PLC available

6.Why choose us?
Eurostars offers One Stop Solutions for:
•Pharmaceuticals industry
•Electronics industry
•Automobile industry
•Printing and food industry
•Commercial building
•VOC treatment and environment protection
•Indoor air quality
•Marine ventilation
Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System
7.FAQ
1:Are you a factory?
--- Yes, we are a professional manufacturer for more than 13 years
2:How do you check the goods?

--- We inspect all the materials when they arrive, and have spot inspection during production process. All goods will be tested and double inspected before delivery, providing 100% guarantee for clients.

3:How to select the suitable models?
---The parameters above is just for your reference. We need you to provide us the air flow, ESP or TSP, cooling capacity, heating capacity or application for our team to design the suitable unit for you.


8.Customer visit us
Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System
9.Air handling unit,air handler delivery or container loading
Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System
10.Installation instruction or installation photo, project photos
Industrial Air Conditioning Air Handling Unit for Hospital Refrigeration System