YMEKRVASDLWD FCA 8,7/15 KV Longitudinal water blocking power cables
PROPERTIES
Application:
1-core Radial- and Longitudinal water blocking power cables 8,7/15 kV with a stranded copper conductor.
Characteristics:
• Radial- and Longitudinal water blocking
• PE outer sheath
• Fire safety according to EN50575 and NEN8012-Fca
| Specifications |
---|
Product group | Power cable >= 1 kV, for permanent installation |
Type | YMeKrvasdlwd Fca 8,7/15 kV |
| |
Standardization | IEC 60502-2 |
Conductor material | Copper |
Conductor surface | Bare |
Conductor category | Class 2c = stranded & compacted |
Material core insulation | Crosslinked polyethylene (XLPE) |
Material outer sheath | MDPE |
Reaction-to-fire according to EN 13501-6: Class | Fca |
Longitudinal water blocking screen | Yes |
Radial water blocking | Yes |
Radial watertight construction | Al/PE |
Max. conductor temperature | 90 °C |
Nominal voltage U0 | 8.7 kV |
Nominal voltage U | 15 kV |
Nominal voltage Umax | 17.5 kV |
YMEKRVASDLWD FCA 8,7/15 KV Longitudinal water blocking power cables specifications
Construction | Net weight (kg/m) | Outer diameter approx. (mm) | Conductor category | Shape of conductor |
---|
1 x 25 rs + as25 Red | 0.887 | 26,7 | Class 2c = stranded & compacted | Round |
1 x 50 rs + as25 Red | 1.138 | 28,7 | Class 2c = stranded & compacted | Round |
1 x 70 rs + as35 Red | 1.45 | 30,3 | Class 2c = stranded & compacted | Round |
1 x 95 rs + as25 Red | 1.636 | 31,9 | Class 2c = stranded & compacted | Round |
1 x 120 rs + as35 Red | 1.979 | 33,4 | Class 2c = stranded & compacted | Round |
1 x 150 rs + as25 Red | 2.175 | 34,9 | Class 2c = stranded & compacted | Round |
1 x 240 rs + as25 Red | 3.162 | 38,9 | Class 2c = stranded & compacted | Round |
1 x 400 rs + as50 Red | 4.734 | 44,3 | Class 2c = stranded & compacted | Round |
1 x 500 rs + as50 Red | 6.034 | 47,6 | Class 2c = stranded & compacted | Round |
1 x 630 rs + as50 Red | 7.385 | 51,7 | Class 2c = stranded & compacted | Round |
Custom designed medium voltage cables
In addition to standard medium voltage cables, we can design and supply bespoke MV cable products developed for your specific applications. Our custom designed cable solutions provide for variants developed and manufactured around a number of parameters, including:
Cross-sectional area: generally 35mm2 up to 100mm2
Number of cores: generally one or three
Solid or stranded aluminium conductors: for applications requiring a lighter cable weight, also often more economical due to lower aluminium prices.
Stranded copper conductors: for applications requiring a smaller overall diameter and higher transmitting properties.
Bedding
Bonded or strippable out semi-conducting layer
Water tightness: longitudinal, longitudinal + quasi-radial, longitudinal + radial
Insulation layers (conductor screen, insulation and insulation screen): XLPE, which is more commonly used for MV cables, or EPR which is more flexible and often better suited to marine and offshore applications.
Metallic screen: to nullify the electric field outside the MV cable. Concentric copper wire screens, Aluminium foil laminate, or extruded lead alloy sheath.
Twisted three-core cable or triplex
Armouring: for mechanical protection. Aluminium wire armoured for single-core cables, Galvanised steel wire armour, strip or tape.
Tapes: Separator tapes to facilitate peeling, water-swellable tapes to prevent water ingress, Conductive tape for core binding.
Outer Sheath: compounds with various properties, tailored to the specific application's requirements, including resistance to oils, greases, rodents, termites, UV and flame, as well as zero halogen emissions. Medium Voltage cable testing
Some of the tests you would expect from a medium voltage cable manufacturer, and which are performed on our MV cables, include:Routine tests: These non-destructive tests are normally carried out on all lengths manufactured.- Conductor resistivity- Spark test on oversheath- Voltage tests on sheath- D.C. voltage test on oversheathSample tests: These potentially destructive tests are normally carried out on every production run.- Examination of conductor and dimensions- Hot set test for XLPE insulation- Insulation and oversheath thickness- Four hour voltage testType tests: These destructive tests are normally carried out in addition to the above tests on commencement of a particular cable supply to validate its design.- Electrical type tests including bending and heat cycle- Non-electrical type tests including mechanical properties after ageing and tests under fire conditions. Packaging&Delivery.
![Ymekrvasdlwd Fca 8, 7/15 Kv Longitudinal Water Blocking Power Cables](//image.made-in-china.com/226f3j00NETVkQiFJWbR/Ymekrvasdlwd-Fca-8-7-15-Kv-Longitudinal-Water-Blocking-Power-Cables.webp)
Packaging Details:Wooden drums,steel wooden drums or as your requirement
Delivery Time:Normally within 7 days(detailly depend on the order quantity)
Contact us
Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software.