380/400/ 415VAC 50Hz 60Hz Online Double Conversion UPS with Isolation Transformer

China 380/400/415VAC 50Hz 60Hz Online Double Conversion UPS with Isolation Transformer, Find details about China Online Double Conversion UPS, 415VAC Online UPS from 380/400/415VAC 50Hz 60Hz Online Double Conversion UPS with Isolation Transformer

Model NO.
Legend Strar Series
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Decentralized
Brand
Upsen
Transfer Time
Zero
Charging Method
Cc/CV
Cooling
Yes
Optional
Solation Transformer
Trademark
UPSEN
Transport Package
Cartons & Wooden Pallet
Specification
CE & ISO Certificate
Origin
China
HS Code
8504402000
Model NO.
Legend Strar Series
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Decentralized
Brand
Upsen
Transfer Time
Zero
Charging Method
Cc/CV
Cooling
Yes
Optional
Solation Transformer
Trademark
UPSEN
Transport Package
Cartons & Wooden Pallet
Specification
CE & ISO Certificate
Origin
China
HS Code
8504402000
380/400/415VAC 50HZ 60HZ online double conversion UPS with isolation transformer
Model:Low Frequency Online UPS Legend Strar Series LS33 10K-80K(3Ph in/3Ph out)

Key Features
1:Active input power factor correction (PFC)
2:DSP technology guarantees high reliability
3:Advanced battery charging management
4:Control designed to withstand all kinds of loads                                
5:Intelligent battery management to prolong battery lifecycle  
6:Highly reliability with the sixth generation IGBT and high speed static switch  
7:Effectively restrain the input THD, raise UPS input power factor, reduces the input THD current       8:UPS system modularization design, N+X redundancy, hot plug online and promotion dilatancy           9:Power module double DSP controller disposing, module independent control, and '0' single point failure risk    
10:Touch screen display, with the simple operation and Intuitive data, optional display language and logo 11:Intelligent self-diagnose function, all kinds of fault protection, large capability of history record storage 12:When mains failure, can directly use the battery to start the ups until the battery discharge to low voltage, when mains recover, can self start UPS.
 
Application
Data center, Industrial equipment, Financial and Securities,Sensitive Electronic Equipment,Wind Power System,Production Equipment,Military,Medical Systems,Network,Instrumentation Large Data rooms, cars, Army Technology, trailers ,transportation industry,Medical Systems, etc.

 
Technical Specification
3P/3P ONLINE UPS SELECTION GUIDE
                                                 LS33 Series 10K - 80Kva
MODEL10K20K30K 40K60K80K
CAPACITY10KVA/        8KW20KVA/ 16KW
30KVA/ 24KW

40KVA/ 32KW
60KVA/ 48KW80KVA/ 64KW
INPUT
Nominal Voltage3 x 380VAC/400VAC (3Ph + N)
Acceptable Voltage Range305VAC ~ 460VAC
Frequency46-54Hz or 56-64Hz
INVERTER
Nominal Voltage3 x 380VAC/400VAC (3Ph + N)
PrecisionStationary: ±1%
 Transitory: ±5% (load variations 100-0-100%)
Frequency50/60 Hz synchronised ±1 %
With mains absent ±0.1 Hz
Max. Synchronisation Speed±1 Hz/s
WaveformPure Sinewave
Total Harmonic Distortion (THDv)<2% (Linear Load)
<5% (Non-linear Load)
Phase Displacement120º ±1% (balanced load)
120º ±2% (imbalances 50% of the load)
Dynamic Recovery Time1 cycle at 98 % of the static value
Admissible Overload110% for 10min; 150% for 60sec ; >160% for 200ms
Admissible Crest Factor3:1
Admissible Power Factor0.6~1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load<1%
Current LimitHigh overload, short-circuit: RMS Voltage Limit
 High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
TypeSolid state
Voltage3 x 380VAC/400VAC (3Ph + N)
Frequency50/60 Hz
Activation CriterionMicroprocessor control
Transfer TimeZero
Admissible Overload150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to BypassImmediate, for overloads above 160%
RetransferAutomatic after alarm clear
MAINTENANCE BYPASS
TypeWithout interruption
Voltage3 x 400V (3Ph + N)
Frequency50/60 Hz
Overall EfficiencyLine Mode90%91%92%93%
Battery Mode90%91%93%93%
BATTERY & CHARGER
Battery Type and Numbers12VDC x 16 pcs12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage192 VDC384 VDC (Based on 32pcs batteries)
Charging MethodCC/CV
Precision ±1%
Charging CurrentMax.: 40 A
Charging Voltage216 VDC432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D x W x H(mm)656 x 405 x 817656 x 405 x 941840 x 432 x 1140975 x 554 x 1286
Net Weight (Kgs)180205295330451519
* Product specifications are subject to change without further notice