1. Product features& Applications1. Non-contact temperature measurement
2. Medical equipment and instruments
3. Thermoelectric conversion
4. Radiation monitoring switch system
5. Consumer electronics
6. Pyrometer
7. Gas analysis
8. Agriculture
9. Animal husbandry
10. Security monitoring
2. Parameters ELECTRICAL CHARACTERISTICS( at 25ºC ) ITEM | CONDITION | RATING | 6.1 Signal Output | - Black Body temperature: 420K
- Chopping Frequency: 1HZ, 0.3~ 3.5HZ △f
- Vd=5V,Rs=47KΩ,the amplifier of Gain 72.5dB
- Measurement method shown in Fig2.
| >3500mVp-p | 6.2 Noise Output | - Chopping Frequency: 1HZ, 0.3~ 3.5HZ △f
- Vd=5V,Rs=47KΩ,the amplifier of Gain 72.5dB
- Measurement method shown in Fig2.
| < 70mVp-p | 6.3 Balance output | - Black Body temperature: 420K
- Chopping Frequency: 1HZ, 0.3~ 3.5HZ △f
- Vd=5V,Rs=47KΩ,the amplifier of Gain 72.5dB
- Measurement method shown in Fig2 and Fig3.
VA = A Element sensitivity(Vp-p) VB = B Element sensitivity(Vp-p) | |VA-VB|/(VA+VB) ×100%≤10% | 6.4 Operating Voltage | Single power supply RS=47KΩ | 2~15V | 6.5 Source Voltage | VD=5V,RS=47KΩ | 0.4~1.0V | 6.6 Circuit Configuration | See Fig.3 | | 6.7 Warm-up Time | After it conneted, it with the measurement amplifier for Fig.3 description that turns on the power supply beforehand, the amplification output is time until stabilizing. | Max: 25 Sec |
7. OPTICAL CHARACTERISTICS ITEM | RATING | 7.1Field of View | 138 degrees from center of Element on Axis X. 125 degrees from center of Element on Axis Y. See Fig 5 | 7.2Response wavelength band | Filter substrate:Silicon Cut on wavelength:5.5±0.5μm Transmission:7~14μm ≥75% | 7.3 Transmission Characteristics of filter | See Fig 6 |
8. ENVIRONMENTAL REQUIREMENTS ITEM | RATING | 8.1 Operating Tmeperature | -30~70 ºC | 8.2 Storage Temperatur | -40~80 ººC | 8.3 Relative Humidity | The sensor shall operate without increase in Noise Output when exposed to 90 to 95% RH at 30ºC continuously | 8.4 Hermetic Seal | No bubbles visible in the 125±5ºC fluorocarbon bath(FC-40) for 20sec | 8.5 Reliability Test | Specified in Appendix1( page13~14) |
9. RoHS COMPLIANCE This product conforms to RoHS regulatin. 10. INSPECTION 10.1 Process inspection 100% inspection: Item 6.1 to 6.3 and 6.5 among the electric performances of item 6. 10.2 OUTGOING INSPECTION Based on statistical sampling inspection method every manufacture lot is inspected for the electrical characteristics item 6.1to 6.3 ,6.5 of the Item 6,and item 5.1 and 5.3 of the appearance of item 5. 11. PACKING The packaging is solid and there isn't breakage 12.process at Failure In case of finding of failure incoming or process inspection after receipt of products, Both sides negotiate to deal with the failure | |
3. TEST CONDITION - Environmental temperature: 25ºC
- Black Body temperature: 420K
- Chopping Frequency: 1HZ, 0.3~ 3.5HZ △f
- the amplifier of Gain 72.5dB
4. Dimension chart5.Pyroelectric Passive Infrared sensor measurement method6. TYPICAL TRANSMISSION CHARACTERISTICS OF FILTER