China 600/1000V Mica+XLPE Insulated, LSZH Sheathed Fire Resistant Power Cables (2-4 cores), Find details about China HDMI Cable, Coaxial Cable from 600/1000V Mica+XLPE Insulated, LSZH Sheathed Fire Resistant Power Cables (2-4 cores)
Voltage Relating: 600/1000V
Cable Construction:
2/3:Insulation: Mica glass tape covered by extruded cross-linked XLPE compound
Cabling: The cores are cabled together in concentric layers with suitable non-hygroscopic fillers.
Color Code:
Insulation Colour
2 - Core: (Brown & Blue)
3 - Core: (Brown, Black & Grey)
4 - Core: (Brown, Black, Grey & Blue)
Sheath Colour
Orange (other colors upon request)
Physical and Thermal Properties:
Temperature range during operation (fixed state): -30°C - +90°C
Temperature range during installation (mobile state): -20°C - +50°C
Minimum bending radius: 8 x Overall Diameter (unarmoured cable)
10 x Overall Diameter (armoured cable)
Electrical Properties:
Conductor Operating Temperature : 90°C
Ambient Temperature : 30°C
FR 1M2XH-R
Fire Performance:
Circuit Integrity | IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1); BS 7846-(F2) |
System circuit integrity | DIN 4102-12, E30 depending on lay system |
Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* |
Minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases | NES 02-713; NF C 20-454 |
Note: Asterisk * denotes superseded standard.
Electrical Properties:
Dielectric test | 3500 V r.m.s. x 5' (core/core) |
Insulation resistance | 1000 MΩ x km (at 20°C) |
Short circuit temperature | 250°C |
Construction Parameters:
Conductor | FR 1M2XH-R | FR 1M2XHAH-R | |||||
No. of Core X Cross Section | No./ Nominal Diameter of Strands | Dia. of Conductor | Nominal Insulation Thickness | Unarmoured Cable | Armoured Cable | ||
Nominal Overall Diameter | Approx. Weight | Nominal Overall Diameter | Approx. Weight | ||||
No*mm2 | No./mm | mm | mm | mm | kg/km | mm | kg/km |
2 Core | |||||||
1.5 | 7/0.53 | 1.59 | 0.7 | 12.2 | 150 | 15.3 | 390 |
2.5 | 7/0.67 | 2.01 | 0.7 | 12.6 | 180 | 16.5 | 450 |
4 | 7/0.85 | 2.55 | 0.7 | 14.7 | 250 | 17.6 | 525 |
6 | 7/1.04 | 3.12 | 0.7 | 16.2 | 290 | 18.8 | 620 |
10 | 7/1.35 | 4.05 | 0.7 | 17.1 | 450 | 21 | 800 |
16 | 7/1.70 | 5.1 | 0.7 | 19.2 | 550 | 23 | 1100 |
25 | 7/2.14 | 6.42 | 0.9 | 20 | 680 | 27 | 1480 |
35 | 19/1.53 | 7.65 | 0.9 | 22 | 940 | 30 | 2000 |
50 | 19/1.78 | 8.9 | 1 | 24 | 1250 | 33 | 2450 |
70 | 19/2.14 | 10.7 | 1.1 | 27 | 1700 | 37 | 3200 |
95 | 19/2.52 | 12.6 | 1.1 | 31 | 2300 | 42 | 4350 |
120 | 37/2.03 | 14.21 | 1.2 | 36 | 3150 | 48 | 6500 |
3-Core | |||||||
1.5 | 7/0.53 | 1.59 | 0.7 | 12.3 | 170 | 16.5 | 420 |
2.5 | 7/0.67 | 2.01 | 0.7 | 13.8 | 200 | 17 | 500 |
4 | 7/0.85 | 2.55 | 0.7 | 15.2 | 300 | 18.5 | 600 |
6 | 7/1.04 | 3.12 | 0.7 | 16.8 | 380 | 19.8 | 785 |
10 | 7/1.35 | 4.05 | 0.7 | 18 | 550 | 22.6 | 1030 |
16 | 1/1.70 | 5.1 | 0.7 | 21 | 760 | 25 | 1370 |
25 | 7/2.14 | 6.42 | 0.9 | 22 | 960 | 29 | 1900 |
35 | 19/1.53 | 7.65 | 0.9 | 24 | 1300 | 32 | 2300 |
50 | 19/1.78 | 8.9 | 1 | 28 | 1700 | 35 | 2900 |
70 | 19/2.14 | 10.7 | 1.1 | 31 | 2400 | 40 | 4000 |
95 | 19/2.52 | 12.6 | 1.1 | 36 | 3250 | 45 | 5400 |
120 | 37/2.03 | 14.21 | 1.2 | 38 | 4000 | 49 | 6450 |
150 | 37/2.25 | 15.75 | 1.4 | 42 | 5000 | 55 | 8200 |
185 | 37/2.52 | 17.64 | 1.6 | 47 | 6100 | 60 | 9800 |
240 | 61/2.25 | 20.25 | 1.7 | 52 | 8000 | 68 | 12300 |
300 | 61/2.52 | 22.68 | 1.8 | 59 | 9850 | 74 | 14800 |
400 | 61/2.85 | 25.65 | 2 | 63 | 13000 | 83 | 17600 |
4-Core | |||||||
1.5 | 7/0.53 | 1.59 | 0.7 | 14.3 | 210 | 16 | 475 |
2.5 | 7/0.67 | 2.01 | 0.7 | 15.2 | 270 | 17.8 | 570 |
4 | 7/0.85 | 2.55 | 0.7 | 17.2 | 380 | 19.8 | 690 |
6 | 7/1.04 | 3.12 | 0.7 | 19 | 440 | 21 | 940 |
10 | 7/1.35 | 4.05 | 0.7 | 20.6 | 670 | 23.3 | 1200 |
16 | 1/1.70 | 5.1 | 0.7 | 23.6 | 820 | 26.5 | 1400 |
25 | 7/2.14 | 6.42 | 0.9 | 26 | 1320 | 30.5 | 2400 |
35 | 19/1.53 | 7.65 | 0.9 | 29 | 1730 | 34 | 2800 |
50 | 19/1.78 | 8.9 | 1 | 32 | 2300 | 38 | 3500 |
70 | 19/2.14 | 10.7 | 1.1 | 38 | 3180 | 44 | 5300 |
95 | 19/2.52 | 12.6 | 1.1 | 41.9 | 4370 | 48.5 | 6700 |
120 | 37/2.03 | 14.21 | 1.2 | 44 | 5400 | 54 | 8500 |
150 | 37/2.25 | 15.75 | 1.4 | 50.8 | 6500 | 59 | 10000 |
185 | 37/2.52 | 17.64 | 1.6 | 55 | 8200 | 64.5 | 12200 |
240 | 61/2.25 | 20.25 | 1.7 | 60.5 | 10600 | 74 | 15400 |
300 | 61/2.52 | 22.68 | 1.8 | 68.5 | 13200 | 82 | 19500 |
400 | 61/2.85 | 25.65 | 2 | 76 | 17000 | 92 | 25500 |
FR 1M2XH-R Curre -Carrying Capacities (Amp)
Nominal Cross Section Area | Reference Method 4 (enclosed in an conduit insulated wall etc) | Reference Method 3 (enclosed in conduit on a wall or ceiling, or in trunking) | Reference Method 1 (clipped direct) | Reference Method 11 (on a perforated cable tray), or Reference Method | |||
one 3-core cable or one 4-core cable 3-phase a.c. | one 2-core cable single phase a.c. or d.c. | one 3-core cable or one 4-core cable 3-phase a.c. | one 2-core cable single phase a.c. or d.c. | one 3-core cable or one 4-core cable 3-phase a.c. | one 2-core cable single phase a.c. or d.c. | one 3-core cable or one 4-core cable 3-phase a.c. | |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
mm2 | A | A | A | A | A | A | A |
1.5 | 16.5 | 22 | 19.5 | 24 | 22 | 26 | 23 |
2.5 | 22 | 30 | 26 | 33 | 30 | 36 | 32 |
4 | 30 | 40 | 35 | 45 | 40 | 49 | 42 |
6 | 38 | 51 | 44 | 58 | 52 | 63 | 54 |
10 | 51 | 69 | 60 | 80 | 71 | 86 | 75 |
16 | 68 | 91 | 80 | 107 | 96 | 115 | 100 |
25 | 89 | 119 | 105 | 138 | 119 | 149 | 127 |
35 | 109 | 146 | 128 | 171 | 147 | 185 | 158 |
50 | 130 | 175 | 154 | 209 | 179 | 225 | 192 |
70 | 164 | 221 | 194 | 269 | 229 | 289 | 246 |
95 | 197 | 265 | 233 | 328 | 278 | 352 | 298 |
120 | 227 | 305 | 268 | 382 | 322 | 410 | 346 |
150 | 259 | 334 | 300 | 441 | 371 | 473 | 399 |
185 | 295 | 384 | 340 | 506 | 424 | 542 | 456 |
240 | 346 | 459 | 398 | 599 | 500 | 641 | 538 |
300 | 396 | 532 | 455 | 693 | 576 | 741 | 621 |
400 | - | 625 | 536 | 803 | 667 | 865 | 741 |
FR 1M2XH-R Voltage Drop (Per Amp Per Meter)
Nominal Cross Section Area | 2-core cable d.c. | 2-core cable single-phase a.c | 3-core or 4-core cable 3-phase a.c. | ||||
1 | 2 | 3 | 4 | ||||
mm2 | mV/A/m | mV/A/m | mV/A/m | ||||
1.5 | 31 | 31 | 27 | ||||
2.5 | 19 | 19 | 16 | ||||
4 | 12 | 12 | 10 | ||||
6 | 7.9 | 7.9 | 6.8 | ||||
10 | 4.7 | 4.7 | 4 | ||||
16 | 2.9 | 2.9 | 2.5 | ||||
|
| r | x | z | r | x | z |
25 | 1.85 | 1.85 | 0.16 | 1.9 | 1.6 | 0.14 | 1.65 |
35 | 1.35 | 1.35 | 0.155 | 1.35 | 1.15 | 0.135 | 1.15 |
50 | 0.98 | 0.99 | 0.155 | 1 | 0.86 | 0.135 | 0.87 |
70 | 0.67 | 0.67 | 0.15 | 0.69 | 0.59 | 0.13 | 0.6 |
95 | 0.49 | 0.5 | 0.15 | 0.52 | 0.43 | 0.13 | 0.45 |
120 | 0.39 | 0.4 | 0.145 | 0.42 | 0.34 | 0.13 | 0.37 |
150 | 0.31 | 0.32 | 0.145 | 0.35 | 0.28 | 0.125 | 0.3 |
185 | 0.25 | 0.26 | 0.145 | 0.29 | 0.22 | 0.125 | 0.26 |
240 | 0.195 | 0.2 | 0.14 | 0.24 | 0.175 | 0.125 | 0.21 |
300 | 0.155 | 0.16 | 0.14 | 0.21 | 0.14 | 0.12 | 0.185 |
400 | 0.12 | 0.13 | 0.14 | 0.19 | 0.115 | 0.12 | 0.165 |
FR400 1M2XHAH-R Current-Carrying Capacities(Amp)
Nominal Cross Section Area | Reference Method 1 (clipped direct) | Reference Method 11 (on a perforated cable tray), or Reference Method | In single-way ducts | Laid direct in ground | ||||
one 2-core cable single phase a.c. or d.c. | one 3-core cable or one 4-core cable 3-phase a.c. | one 2-core cable single phase a.c. or d.c. | one 3-core cable or one 4-core cable 3-phase a.c. | one 2-core cable single phase a.c. or d.c. | one 3-core or 4-core cable 3-phase a.c. | one 2-core cable single phase a.c. or d.c. | one 3-core or 4-core cable 3-phase a.c. | |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
mm2 | A | A | A | A | A | A | A | A |
1.5 | 27 | 23 | 29 | 25 | - | 23 | - | 28 |
2.5 | 36 | 31 | 39 | 33 | - | 30 | - | 36 |
4 | 49 | 42 | 52 | 44 | - | 40 | - | 48 |
6 | 62 | 53 | 66 | 56 | - | 50 | - | 60 |
10 | 85 | 73 | 90 | 78 | - | 65 | - | 80 |
16 | 110 | 94 | 115 | 99 | 115 | 94 | 140 | 115 |
25 | 146 | 124 | 152 | 131 | 145 | 125 | 180 | 150 |
35 | 180 | 154 | 188 | 162 | 175 | 150 | 215 | 180 |
50 | 219 | 187 | 228 | 197 | 210 | 175 | 255 | 215 |
70 | 279 | 238 | 291 | 251 | 260 | 215 | 315 | 265 |
95 | 338 | 289 | 354 | 304 | 310 | 260 | 380 | 315 |
120 | 392 | 335 | 410 | 353 | 355 | 300 | 430 | 360 |
150 | 451 | 386 | 472 | 406 | 400 | 335 | 480 | 405 |
185 | 515 | 441 | 539 | 463 | 455 | 380 | 540 | 460 |
240 | 607 | 520 | 636 | 546 | 520 | 440 | 630 | 530 |
300 | 698 | 599 | 732 | 628 | 590 | 495 | 700 | 590 |
400 | 787 | 673 | 847 | 728 | 660 | 560 | 790 | 670 |
FR400 1M2XHAH-R Voltage Drop (Per Amp Per Meter)
Nominal Cross Section Area | 2-core cable d.c. | 2 cables, single-phase a.c. | 3 or 4 cables, 3-phase a.c. | 2 cables, single- phase a.c. In ducts or in ground | 3 or 4 cables, 3-phase a.c. In ducts or in ground | ||||
1 | 2 | 3 | 4 | 5 | 6 | ||||
mm2 | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | ||||
1.5 | 31 | 31 | 27 | 31 | 25 | ||||
2.5 | 19 | 19 | 16 | 19 | 15 | ||||
4 | 12 | 12 | 10 | 12 | 9.7 | ||||
6 | 7.9 | 7.9 | 6.8 | 7.9 | 6.5 | ||||
10 | 4.7 | 4.7 | 4 | 4.7 | 3.9 | ||||
16 | 2.9 | 2.9 | 2.5 | 2.9 | 2.6 | ||||
|
| r | x | z | r | x | z |
|
|
25 | 1.85 | 1.35 | 0.16 | 1.9 | 1.6 | 0.14 | 1.65 | 1.9 | 1.6 |
35 | 1.35 | 1.35 | 0.155 | 1.35 | 1.15 | 0.135 | 1.15 | 1.35 | 1.2 |
50 | 0.98 | 0.99 | 0.155 | 1 | 0.86 | 0.135 | 0.87 | 1 | 0.87 |
70 | 0.67 | 0.67 | 0.15 | 0.69 | 0.59 | 0.13 | 0.6 | 0.69 | 0.61 |
95 | 0.49 | 0.5 | 0.15 | 0.52 | 0.43 | 0.13 | 0.45 | 0.52 | 0.45 |
120 | 0.39 | 0.4 | 0.145 | 0.42 | 0.34 | 0.13 | 0.37 | 0.42 | 0.36 |
150 | 0.31 | 0.32 | 0.145 | 0.35 | 0.28 | 0.125 | 0.3 | 0.35 | 0.3 |
185 | 0.25 | 0.26 | 0.145 | 0.29 | 0.22 | 0.125 | 0.26 | 0.29 | 0.25 |
240 | 0.195 | 0.2 | 0.14 | 0.24 | 0.175 | 0.125 | 0.21 | 0.24 | 0.21 |
300 | 0.155 | 0.16 | 0.14 | 0.21 | 0.14 | 0.12 | 0.185 | 0.21 | 0.19 |
400 | 0.12 | 0.13 | 0.14 | 0.19 | 0.115 | 0.12 | 0.165 | 0.19 | 0.18 |
Note : r = conductor resistance at operating temperature
x = reactance
z = impedance