Megatro Telecom Guyed Mast (MGT-GM007)

China Megatro Telecom Guyed Mast (MGT-GM007), Find details about China Guyed Mast, Guyed Tower from Megatro Telecom Guyed Mast (MGT-GM007)

Model NO.
MGT-GM007
Condition
as Per Client Requirements and Data
We Can Design by Pls& Tower Software
as Per Client Requirements and Data
Trademark
MEGATRO
Transport Package
Export Stnadard Package
Specification
AS PER CLIENT
Origin
Shandong, China
HS Code
73082000
Model NO.
MGT-GM007
Condition
as Per Client Requirements and Data
We Can Design by Pls& Tower Software
as Per Client Requirements and Data
Trademark
MEGATRO
Transport Package
Export Stnadard Package
Specification
AS PER CLIENT
Origin
Shandong, China
HS Code
73082000
GUYED MASTS
Guyed masts are utilized to achieve the maximum in elevation and loading at an economical cost. The addition of heavier braced sections and torque arm guy points allow a tower to be engineered custom to its loading specifications.
The face width is the measurement of each side of the triangular structure that sits upon a tapered bottom section that is anchored to the foundation base by a pivot pin. The tower and mast is supported by galvanized steel guy cables of varying sizes.
Many tower and mast models end in two numbers that indicate the face width size in inches. However, the same model has various loading capabilities based upon the thickness and size of steel pipe or angle members used for vertical support and horizontal and diagonal bracing.
MEGATRO's guyed masts are secured with a pivot base and can reach heights up to 1, 100 feet. MEGATRO's all welded design provides maximum tower stiffness, minimum twist/sway and bending. Masts come with integral wave guide clips and climbing ladder and come with heavy duty guy cable and hardware.
MEGATRO's guyed mast can accommodate a variety of broadcasting, cellular, and microwave antennas. Besides, MEGATRO guyed tower also used in power transmission line project. MEGATRO also offers a wide variety of accessories and mounts.
After fabrication all guyed masts are delivered to the galvanizing facility to be Hot DIP Galvanized. Masts are processed through the facility by Caustic Cleaning, Pickling, and then Fluxing. These strict procedures insure years of maintenance free towers.
Manufacturers provide multiple designs from tubular or round solid Incandescent Lighting 1 to angle iron legs; Either knock down or all welded sections are fabricated.
If the tower structure's elevation is over 200 feet it will be required to have obstruction lighting. Some structures close to an airport will require lighting no matter what height the structure is.
Availability size: Based on the customer's requirements.
Material: Chinese material or as per clients requirement
Package: Both parties discuss before delivery
Terms of Payment: L/C, T/T
Minimum Order Quantity: 1 SET
Port of Loading: Qingdao Port
Lead Time: One month or based on the customer's needs
MEGATRO provide guyed mast tower design with below requirements
Megatro Telecom Guyed Mast (MGT-GM007)

Design Requirements and Basic of Design
MEGATRO TOWERS will guarantee the overall safety of the tower. MEGATRO TOWERS will submit design calculation report for member design of tower and overall structural stability of the structure, which is signed by a charted structural Engineer.
MEGATRO will supply the skeleton to scale, showing the assembly of the structures, the antenna mounting levels, other detail drawings etc.
The calculation method to be adopted for tower design will be decided by MEGATRO TOWERS with the consent of the client.
All materials will comply with British Standard (hereinafter called BS), Japanese Industrial Standard (hereinafter called JIS) or equivalent standards. The permissible stress of the materials will comply with BS, standard by Architectural Institute of Japan (hereinafter call AIJ) or equivalent. The standards adopted for all materials will be stated separately.

General Design Criteria
Mast will be designed based on GB, BS 8100, TIA/EIA-222-G-2006, IS 802 & IS875 or equivalent international standards.

APPLICABLE STANDARD AND CODES
All towers manufactured and design shall be generally in accordance with latest revision of the following standards except where specifically directed otherwise.
General
IEC 60826  - Design criteria of overhead lines
IEC 60652  - Loading tests on overhead line structures
ISO 1459   - Metallic coatings - Protection against corrosion by Hot Dip Galvanizing
ISO 1461   - Hot dip galvanized coatings on fabricated iron and steel articles
ISO 12944  - Paint coatings, corrosion protection, and structural steelwork
ISO 898-1   - Mechanical properties of fasteners. Part 1-Bolts, Screws and studs
ISO 630    - Structural Steels - plates, wide flats, bars, sections and profiles
ISO 657    - Hot rolled structural steel plates tolerances on dimensions and shape
ISO 7411  - Hexagon Bolts for high strength structural bolting with large width across flats
ISO 657-5   - Hot rolled Structural Steel Sections equal and unequal leg angles
ISO 7452   - Hot rolled structural steel plates tolerances on dimensions and shape
BS EN 50341-1 -Overhead electrical lines exceeding AC 45kV -General Requirements
BS 8004    - Code of Practice for Foundations
BS 8110    - Structural use of concrete
ANSI10-97   - Design of latticed steel transmission structures
IEC 60050 (151)                         International Electro-technical Vocabulary
                                       Part 51 Electrical and Magnetic Devices
IEC 60050 (601)                      Chapter 601: Generation, transmission and distribution of electricity-General
IEC 60050 (601)                    Chapter 601: Generation, transmission and distribution of electricity-Operation
IEC 60059                              IEC standard current ratings
Chinese Standard
NoCodeDESCRIPTION
1GB/T2694-2003Power Transmission line Steel tower - Technical requirements for manufacturing
2JGJ81-2002Technical specification for welding for steel structure of building
3GB9787-88Measuring and allowable tolerance for hot-rolled equal angle
4GB709-88Measuring and allowable tolerance for hot-rolled plate and strip
5GB/T699-1999Quality Carbon Structural Steel
6GB/T1591-1994Low alloy high strength structural Steel
7GB700-88Carbon Structural Steel
8GB222-84Method of sampling steel for determination of chemical composition and permissible variations
9GB/T228-2002Method for Tensile testing of metals
10GB/T232-1999Method for Bending test of metals
11GB/T5117-1995Carbon Welding Rod
12GB/T5118-1995Low Alloy Welding Rod
13GB/T8110-1995Welding wires for gas shielding arc welding of carbon and low alloy steels
14GB/T10045-2001Carbon steel flux cored electrodes for arc welding
15JB/T7949-1999Weld outer dimensions for steel construction
16GB50205-2001Test Standard for Acceptance of Steel Structure
17GB/T470-1997Zinc Ingot
18GB3098.1-2000Mechanical properties of fasteners-Part 1:Bolts, screws and studs
19GB3098.2-2000Mechanical properties of fasteners-Part2: Nuts, and thread
20GB3098.3-2000Mechanical properties of fasteners-Part3: Fastening screw
21GB/T5780-2000Helical Bolts Grade C
22GB/T41-2000Helical Nuts Grade C
23GB/T90-2002Flat Washer Grade C
24GB/T13912-2002Metal Coating, Technical Requirement and Test Method for Hot-dip galvanized Metal Parts
 
 
American Standards:
StandardDescription
ASTM A6/A6MStandard specification for general requirements for rolled structural steel bars, plates, and sheet piling.
ASTM - 6    -  General Requirements for delivery of Rolled Steel Plates, Shapes, sheet Piling Bars for  structural used
ASTM A36/A36-M-97aStandard specification for Carbon structural steel
ASTM A123 / A123M-02Standard specification for Zinc (Hot-Dip Galvanized) Coatings on iron and steel products
ASTM A143 / A143M-03Standard Practise for Safeguarding Against Embitterment of Hot-Dip Galvanized Structural Steel Products and Procedure for Detecting Embitterment
ASTM A153/ A153M-05Standard specification for zinc coating (Hot-Dip) on iron and steel hardware
ASTM A - 194  -   Grade for bolt
ASTM A239Standard practice for locating the thinnest spot in a zinc (Galvanized) Coating on Iron or Steel Articles
ASTM A242Standard specification for High-Strength Low-Alloy Structural steel
ASTM A307Standard Specification for Carbon Steel Bolts and Studs, 60000 PSI Tensile strength
ASTM A370-06Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM A325Standard Specification for structural bolts, steel, Heat treated 120/105 ksi minimum tensile strength
ASTM A-325 or A-354  -  Galvanized hexagonal head of  connection bolt
ASTM A325-97Standard Specification for High-strength Bolts for structural steel Joints
ASTM A384 / A384M-02Standard Practise for Safeguarding Against Warpage and Distortion During Hot-Dip Galvanizing of Steel Assemblies.
ASTM A394-93Standard Specification for steel Transmission Tower, Bolts, Zinc Coated and Bare
ASTMA - 563-    Class and size of nuts
ASTMA - 572   - Chemical composition of steel
ASTM A572/A572-97cStandard specification for High-Strength Low-Alloy Columbium-Vanadium Structural steel
 ASTMA - 615  -   The anchor bolt material
ASTM A673 / A673M-07Standard Specification for Sampling Procedure for Impact  Testing of Structural Steel
ASTM B201Standard practice for testing Chromatic coating on Zinc and Cadmium surfaces
ASTM  E94-93Standard Guide for Radiographic Testing
ASTM E 709-95Standard Guide for Magnetic Particle Examination
ASCE Manual 72    -  Load testing a simple structure
ASCE 10-97Standard Design of latticed steel transmission structures
AWS D1.1American Welding Society D1,1/D1,1M structural Welding code- Steel
ANSI B-182-2Bolts, nuts and washers dimensions
 
DIN VDE 0101                       -  Isokeraunic Level
VDE 0201                              - Climatic and environmental   conditions
CVDE 0210                           -  Minimum safety factors under    simultaneous working loads
ISO R898 Mechanical Properties of Fasteners
BS EN ISO 1461:1991 - High dip galvanized coatings on fabricated iron and steel articles. Specifications and standards
A) BS 5950: Welding Terms And Symbols
B) BS 729: Hot - Dip Galvanised Coating On Iron And Steel Articles
C) BS 2901: Filler Rods And Wires For Gas Shielded Arc Welding: Part 1 Ferritic Steels
D) BS 3692: ISO Metric Precision Hexagon Bolts, Screws And Nuts
E) BS 4360: Weldable Structural Steel
F ) BS 5135: Metal - Arc Welding Of Carbon And Carbon Manganese Steel
G) BS 5950: Part 1: Code Of Practice For Loading Latticed Tower & Masts
Part 2: Guide To The Background And Use Of Part 1"Code OF Practice For Loading"
Part 3: Strength Assessment of Members
H) DD 133 (1986): Code Of Practice For Loading Latticed Tower & Masts
I) BS 4592 (1987): Part 2: Specification For Expanded Metal Grating Panels
J) BS 4592 (1977): Code Of Practice For Protective Coating Of Iron And Steel Structure Against Corrosion
K) BS 4190: Bracing & Flanged Bolts
L) BS 4190: Rolled Steel sections, Flats & Plates
 
Moreover, we also can design tower foundation according to below standard:
BS 8004  - Code of Practice for Foundations
BS 8110  - Structural use of concrete
BS 4449  - Carbon steel bars for the reinforcement of concrete
If any special requirement, we can design and discuss with client.