Th0400 Precision Coaxial Shunt and 5ppm Accuracy Precision DC and AC Current Shunts

China Th0400 Precision Coaxial Shunt and 5ppm Accuracy Precision DC and AC Current Shunts, Find details about China I/V Transfer Standard, Standard Resistance from Th0400 Precision Coaxial Shunt and 5ppm Accuracy Precision DC and AC Current Shunts

Model NO.
TH0400
Frequency Range
DC~100kHz
DC Ratio Accuracy
20ppm
Phase Displacement
5μrad
Trademark
TUNKIA
Origin
Chn
HS Code
9030339000
Model NO.
TH0400
Frequency Range
DC~100kHz
DC Ratio Accuracy
20ppm
Phase Displacement
5μrad
Trademark
TUNKIA
Origin
Chn
HS Code
9030339000
TH0400 Precision Coaxial Shunt

Th0400 Precision Coaxial Shunt and 5ppm Accuracy Precision DC and AC Current Shunts

Introduction
  1. TH0400, a series of 14 various ranges precision coaxial shunts.
  2. TH0400 can work in the DC ~ 100 kHz frequency range, converting 1 mA ~ 100 A nominal current into 1 V small current.
  3. DC ratio accuracy: 20 ppm;AC/DC difference: 20 ppm; phase displacement: 5.
  4. It is suitable for calibration of AC/DC high current source, current sensor, DC shunt, and other occasions where current needs to be measured precisely.

Features
  1. The nominal voltage is 1 V, can measure current by directly matching high-precision voltmeters or other measurement instruments.
  2. For 1 mA, 10 mA and other high resistance current shunts, combine with the model TH0600 to avoid errors caused by wire connection or input impedance drops of digital meters at high frequency.
  3. Compared to 0.5 V, 0.8 V and other voltage value, the 1V nominal voltage has a higher noise ratio, easier current conversion, faster error calculation, and accords with the 1-2-5 sequence principle of modern measurement.
  4. Precision components and production processes ensure the resistance value stable, the typical resistance change value is ±5 μΩ/Ω in 1 year, and the maximum resistance change value is ±16 μΩ/Ω in 1 year.
  5. Good heat dissipation, lower temperature coefficient and self-heating power factor ensure a good stability.
  6. Small phase displacement between the input current and the sampled voltage, the phase displacement is less than 0.0015 ° even at 1 kHz. This feature is critical for the measurement of non-sinusoidal and wideband signals, applied to analyze power quality and calibrate digital power meters.
  7. The capacity of loading current and withstanding current impulse is limited, but you can use a set of shunts to obtain a wide range of current measurement.

Specification
Resistance
InomUnom
(V)
Rnom
(Ω)
Initial Deviation (μΩ/Ω)Stability
(μΩ/Ω)
Temperature Coefficient
(ppm/K)
Power Coefficien
(μΩ/Ω)
Imax LoadInstantaneous Current (<5 s)
1 mA11 k50182.512 mA3 mA
10 mA110050182.5120 mA50 mA
20 mA15050182.5140 mA100 mA
50 mA12050182.51100 mA200 mA
100 mA11050182.52200 mA500 mA
200 mA1550182.54500 mA1 A
500 mA1250182.5121 A2 A
1 A1150184.0251.5 A4 A
2 A10.550184.0252.5 A5 A
5 A10.250184.0305.5 A10 A
10 A10.150184.06011 A25 A
20 A10.0550184.07522 A40 A
50 A10.0250184.510055 A90 A
100 A10.0150184.5100110 A180 A
  1. Remarks:
: In the calibration temperature environment, the deviation of the measured resistance value from the nominal resistance value after the rated DC current is applied for ten minutes. Higher precision can be customized according to user requirements, such as: 20μΩ/Ω.
: The initial deviation of the DC resistance value has included the power coefficient influence error under the nominal current. When measuring other non-nominal currents, additional measurement accuracy should be introduced. The calculation formula is:

Current
InomMax. AC/DC Diff. (ppm*FS)Max. Phase Displacement (μrad)
50 Hz1 kHz100 kHz53 Hz400 Hz1 kHz10 kHz50 kHz100 kHz
1 mA25501501010151205001000
10 mA2025505510100400800
20 mA2025505510100400800
50 mA2025505510100400800
100 mA202525551060300500
200 mA202525551060300500
500 mA202525551060300500
1 A202530551060300500
2 A2030501010151105001000
5 A20308010152520010002000
10 A253010010204030015003000
20 A253010010255040020004000
50 A305015010306550025005000
100 A305020020408060030006000
Remarks: : FS is full-scale value


Dimension and Weight
ModelNameDimension
(W × H × D, mm)
Weight (kg)
TH0400 - 1 mA1 mA shunts90 × 25 × 250.1
TH0400 - 10 mA10 mA shunts90 × 25 × 250.1
TH0400 - 20 mA20 mA shunts90 × 25 × 250.1
TH0400 - 50 mA50 mA shunts90 × 25 × 250.1
TH0400 - 100 mA100 mA shunts90 × 25 × 250.1
TH0400 - 200 mA200 mA shunts110 × 70 × 700.2
TH0400 - 500 mA500 mA shunts110 × 70 × 700.2
TH0400 - 1 A1 A shunts110 × 70 × 700.2
TH0400 - 2 A2 A shunts110 × 70 × 700.2
TH0400 - 5 A5 A shunts110 × 70 × 700.2
TH0400 - 10 A10 A shunts180 × 130 × 1301
TH0400 - 20 A20 A shunts180 × 130 × 1301
TH0400 - 50 A50 A shunts260 × 200 × 2002.5
TH0400 - 100 A100 A shunts260 × 200 × 2002.5
Remarks: Partial or full purchases are available, particular requirements can be customized by resistance and sampled voltage (e.g. 0.5 V and 0.8V).

TH0230 Wiring AC/DC I/V transfer standard

Th0400 Precision Coaxial Shunt and 5ppm Accuracy Precision DC and AC Current Shunts
Introduction
  1. TH0230, a series of I/V high-precision AC/DC current transfer standard, are divided into A, B, C, D four versions according to the accuracy.
  2. TH0230 can work in the DC, 10HZ~5kHz frequency range (3dB signal bandwidth ≥100kHz), converting 0.1A ~ 1kA nominal current into 1V small voltage.
  3. AC ratio measurement accuracy: 5 ppm(TH0230D), Best AC ratio measurement accuracy: 100 ppm(TH0230D), supporting positive and negative current measurement.
  4. DC current multi-lap zero adjustment potentiometer and locking device, primary input and secondary output have good electrical isolation, high common mode rejection ratio (CMRR).
  5. It is convenient to be connected into the large current loop with wiring structure. The secondary output can be equipped with high-precision voltmeter to achieve high-precise measurement of current.
  6. It is suitable for calibration of AC/DC high current source/meter (such as calibrator for clamp-meter), current sensor/transformer, electric welder, micro-ohmmeter and other occasions where current needs to be measured precisely.
  7. TH0230 can be used with broadband AC/DC V/V voltage divider, dual-channel voltage vector analyzer to set up high-precision AC/DC power/energy measurement system.

Specification
ModelPrimary Inom (A)Secondary Unom (V)measurement bandwidth
(kHz)
Best Ratio Measurement Accuracy (ppm*FS)
TH0230ATH0230BTH0230CTH0230D
DCAC@
53Hz
DCAC@
53Hz
DCAC@
53Hz
DCAC@
53Hz
TH0230X-0.1A0.11305025025120101205120
TH0230X-0.2A0.21305025025120101205120
TH0230X-0.5A0.51≥505025025120101205120
TH0230X-1A11≥1005020025100101005100
TH0230X-2A21≥1005020025100101005100
TH0230X-5A51≥1005020025100101005100
TH0230X-10A101≥1005020025100101005100
TH0230X-20A201≥1005020025100101005100
TH0230X-50A501≥1005020025100101005100
TH0230X-100A1001≥1005020025100101005100
TH0230X-200A2001≥1005020025100101005100
TH0230X-500A5001≥1005020025100101005100
TH0230X-1kA1k1≥1005025025120101207120
Note : FS is full-scale value
  1. Measurement range:(10%~110%)*FS,positive and negative current measurement;
  2. Measuring frequency:DC,10Hz~5kHz


TH0240 Threading AC/DC I/V transfer standard
Th0400 Precision Coaxial Shunt and 5ppm Accuracy Precision DC and AC Current Shunts
Introduction
  1. TH0240, a series of I/V high-precision AC/DC current transfer standard, are divided into A, B, C, D four versions according to the accuracy.
  2. TH0230 can work in the DC, 10HZ~5kHz frequency range (3dB signal bandwidth ≥100kHz), converting 200A ~ 10kA nominal current into 1V small voltage.
  3. Best DC ratio measurement accuracy: 5 ppm(TH0240D), Best AC ratio measurement accuracy: 100 ppm(TH0240D), supporting positive and negative current measurement.
  4. DC current multi-lap zero adjustment potentiometer and locking device, primary input and secondary output have good electrical isolation, high common mode rejection ratio (CMRR).
  5. It is convenient to be connected into the large current loop with threading structure. The secondary output can be equipped with high-precision voltmeter to achieve high-precise measurement of current.
  6. It is suitable for calibration of AC-DC high current source/meter (such as calibrator for clamp-meter), current sensor/transformer, electric welder, micro-ohmmeter and other occasions where current needs to be measured.
  7. TH0230 can be used with broadband AC/DC V/V voltage divider, dual-channel voltage vector analyzer to set up high-precision AC/DC power/energy measurement system.
Specification
ModelPrimary Inom (A)Secondary Unom (V)measurement bandwidth
(kHz)
Best Ratio Measurement Accuracy (ppm*FS)
TH0240ATH0240BTH0240CTH0240D
DCAC@
53Hz
DCAC@
53Hz
DCAC@
53Hz
DCAC@
53Hz
TH0240X-200A2001≥100502002510010100--
TH0240X-500A5001≥100502002510010100550
TH0240X-1kA1k1≥100502002510010100550
TH0240X-2kA2k1≥100502002510010100550
TH0240X-5kA5k1≥100502002512010120--
TH0240X-10kA10k1≥100502002515010---
Note : FS is full-scale value
  1. Measurement range:(10%~110%)*FS,positive and negative current measurement;
  2. Measuring frequency:DC,10Hz~5kHz

Th0400 Precision Coaxial Shunt and 5ppm Accuracy Precision DC and AC Current Shunts

Th0400 Precision Coaxial Shunt and 5ppm Accuracy Precision DC and AC Current Shunts
Th0400 Precision Coaxial Shunt and 5ppm Accuracy Precision DC and AC Current Shunts