China Secondary Current Injection Relay Protective Tester, Find details about China Protection Relay Test, Protective Relay Test System from Secondary Current Injection Relay Protective Tester
Phase current output ( RMS ) | 0~40A/phase accuracy: 0.5% |
3-phase in parallel output (RMS) | 0~120A |
Phase current values allowed to work a long time (RMS) | 10A |
Phase current max output power | 420VA |
3-phase in parallel current max output power | 900VA |
3-phase in parallel current max output allowable working time | 10s |
Frequency range | 0~1000Hz; accuracy: 0.001Hz |
Overtone order | 2~20; phase :0~360°; accuracy: 0.1° |
Current output | 0~±30A/phase; accuracy: 0.5% |
Phase voltage output (RMS) | 0~125V/phase, accuracy: 0.5% |
Line voltage output (RMS) | 0~250V |
Phase voltage / Line voltage output power | 75VA/100VA |
Frequency range | 0~1000Hz accuracy: 0.001Hz |
Overtone order | 2~20; phase :0~360°; accuracy: 0.1° |
Phase voltage output range | 0~±150V accuracy: 0.5% |
Line voltage output range | 0~±300V |
Phase voltage / Line voltage output power | 90VA/180VA |
Switch input terminals | 8 pairs |
Dead contact | 1-20mA, 24V active output inside the device. |
Potential flip | 0--6V DC low level; 15-250V DC high level |
Switch output terminals | 4 pairs, dead contact, rupturing capacity: 110V/2A, 220V/1A |
Range | 1ms~9999s |
Accuracy | 1ms |
Dimension | 455×530×220mm |
Weight | 30Kg |
AC220V | 220V±10% | 50Hz,10A |