40.5kv Outdoor High Voltage Isolating Switch (GW5)

China 40.5kv Outdoor High Voltage Isolating Switch (GW5), Find details about China Isolating Switch, Outdoor Isolating Switch from 40.5kv Outdoor High Voltage Isolating Switch (GW5)

Model NO.
GW5
Poles Number
3
Certification
ISO9001-2000, CE, CCC
Rated Voltage
40.5kv
Rated Current
630A,1000A,1250A,1600A
Trademark
VACEM
Origin
Wenzhou, China
Model NO.
GW5
Poles Number
3
Certification
ISO9001-2000, CE, CCC
Rated Voltage
40.5kv
Rated Current
630A,1000A,1250A,1600A
Trademark
VACEM
Origin
Wenzhou, China
1.General description
    GW5 outdoor isolating switch is an outdoor H.V. circuit electric appliance in AC 50Hz,rated voltage 40.5kV,72.5kV and 126kV.It can be used for H.V. circuit making under no-load condition and electric-disconnecting inn inspection of H.V. gereratrix,appliances as circuit breaker and live H.V. wire.Also,it can be used to make small capacitance of inductive current.
2.Main technical parameter
ClassestypeSingle one weight(kg)Rated voltage(kV)Rated current(A)Isolating switchEarthing switchEarthing kinds
peak withstand current(kA)Short time withstand current(kA)peak withstand current(kA)Short time withstand current(kA)
I typeII typeI typeII type
Common type(anti-pollution type)VGW5-40.5/9240.56305020(4s)508020
(4s)
31.5
(4s)
No.earthing single earthing double earthing
VGW5-DI-II40.5941000
12508031.5(4s)
1600
3.Structure characteristics
    
Each unipolar equipment is firmed in a base with two post insulators,shaping a V with intersection 50.The main structures as below:base,post insulator.terminal base,contact,earthing switch,earthing static contact and cable terminal.

    This switch is sorted by earthing-free,single earthing and double earthing.There is a mechanical interlocking between main principal axis and earthing switch.It is equipped with an auxiliary switch.It has manual and automatical operation ways.
4.Features
a.Making current freely.Turning flexibility due to rolling bearing,which leading to operational labor saving.
b.It is transmitted by level gear to make the two pillars making current consistently.
c.The opening and closing brake has limited switch to ensure the contactors at the best position.Meanwhile,the handle will be buckled by lock ring after operation.
d.Big clearance between open contacts,sufficient insulating and disconnecting fracture to ensure the operation safety.
e.It has earthing-free,single earthing and double earthing.There is a reliable mechanical inter locking between principal axis and earthing to ensure safety.Users can choose the earthing way accordingly.
f.Operation mechanism can be installed under either pole according to users.The operating effects are same.
5.International fairs
40.5kv Outdoor High Voltage Isolating Switch (GW5)
6. Company show
40.5kv Outdoor High Voltage Isolating Switch (GW5)40.5kv Outdoor High Voltage Isolating Switch (GW5)40.5kv Outdoor High Voltage Isolating Switch (GW5)40.5kv Outdoor High Voltage Isolating Switch (GW5)40.5kv Outdoor High Voltage Isolating Switch (GW5)