Smartgen ATS Controller Hat520 Hat520n

China Smartgen ATS Controller Hat520 Hat520n, Find details about China ATS Controller, Hat520n from Smartgen ATS Controller Hat520 Hat520n

Model NO.
HAT520N
Weight
0.65kg
Trademark
Smartgen
Transport Package
Original Package
Specification
139*120*50(mm)
Origin
Shenzhen
HS Code
8503009090
Model NO.
HAT520N
Weight
0.65kg
Trademark
Smartgen
Transport Package
Original Package
Specification
139*120*50(mm)
Origin
Shenzhen
HS Code
8503009090
Smartgen ATS Controller HAT520 HAT520N
 

The powerful Microprocessor contained within the HAT520N ATS controller allows for precision voltage (2-way 3-phase/single phase) measuring and make accurate judgment on abnormal voltage (power lost, over/under voltage, over/under frequency, loss of phase, phase sequence wrong) and control ATS to transfer after the delay has expired. This controller is suitable for NO Breaking ATS. When 1# power is abnormal, the controller will send signal to start genset after the "1# abnormal delay" has expired. "Three remote" (remote control, remote measurement and remote communication) function can be implemented with the help of LINK communication port.

PERFORMANCE AND CHARACTERISTICS

HAT520N ATS controller owns performance and characteristics are shown as below,

1) Measure and display 2-way 3 phase Voltage and Frequency:

1#                                 2#

Line voltage   (Uab, Ubc, Uca)    Line voltage   (Uab, Ubc, Uca)

Phase voltage (Ua, Ub, Uc)        Phase voltage (Ua, Ub, Uc)

Frequency    Hz                 Frequency    Hz

2) Over/under voltage, loss of phase, phase sequence wrong, over/under frequency protection function. As default, phase sequence wrong protection and over/under frequency protection are disable; however, users can set the protection function as need.

3) Parameters can be set via PC software using SG72 module (USB to LINK) or other converse module.

4) The voltage normal delay of 1# or 2#can be set in (0~60) seconds and the Genset start delay can be set in (0~3600) seconds.

5) The voltage abnormal delay of 1# or 2#can be set in (0~60) seconds and the Genset stop delay can be set in (0~3600) seconds.

6) "1# power priority", "Auto/Manual", "No priority" and "2#power priority" can be set via controller front panel.

7) Closing output signal can be set as on intervals or as continuous output.

8) Applicable for 2 isolated neutral line.

9) Auto/Manual mode. In manual mode, ATS transfer 1# switch or 2# switch can be implemented via panel pushbutton.

10) LEDs mounted on front panel can clearly show ATS running status.

11) The output contactor capacity of 1# and 2#power supply transfer relay (1#CLOSE, 2#CLOSE) is 16A AC250V, volts-free contact, can be directly used in driving switch to transfer.

12) The output contactor capacity of Genset start relay (GENS START) is 7A AC250V/7A DC28V, volts-free N/C contact.

13) Suitable for various AC systems (3 phase 4-wires, 2-phase 3-wires and single-phase 2-wire).

14) Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting,compact structure with easy installation.

Function ItemParameter
DisplayLED
AC System1P2W/2P3W/3P4W
Alternator Frequency50/60Hz
Monitor InterfaceLINK
Programmable InterfaceLINK
Switch Over Priority.
Applicable Switch TypeNo break position
DC SupplyAC(170~277)V
Case Dimensions(mm)139*120*50(L*W*H)
Panel Cutout(mm)130*111
Operating Temp.(-25~+70)ºC
Controller Hat500

- The Hat500 is an Automatic Start Control Module designed to automatically start and stop diesel and gas generating sets that include non electronic engines.

- The module also provides excellent engine monitoring and protection features.

 

Benefits

-In buit engine diagnostics removes the requirement for service equipment.

- License free PC software.

- Modules help to improve the life cycle of engine starter motors.

- On site module configuration.

- User friendly set-up and button layout.

 

The powerful Microprocessor contained within the HAT520N ATS controller allows for precision voltage (2-way 3-phase/single phase) measuring and make accurate judgment on abnormal voltage (power lost, over/under voltage, over/under frequency, loss of phase, phase sequence wrong) and control ATS to transfer after the delay has expired. This controller is suitable for NO Breaking ATS. When 1# power is abnormal, the controller will send signal to start genset after the "1# abnormal delay" has expired. "Three remote" (remote control, remote measurement and remote communication) function can be implemented with the help of LINK communication port.