China Ysf15 Medical Handheld Cheap Patient Monitor Hot Sale Patient Monitor, Find details about China Hot Sale Patient Monitor, Patient Monitor from Ysf15 Medical Handheld Cheap Patient Monitor Hot Sale Patient Monitor
Physical Specifications | |||||
Dimension and weight | Dimension | 330mm(W)*260mm(H)*140mm(D) | |||
Weight | standard configuration: 4 kg | ||||
Operation environment | Power requirements | AC 90-300V, 50/60HZ, 60W | |||
Power | 90VA | ||||
Temperature | 0-40degree | ||||
Humidity | 0-93% non-condensing | ||||
Safety | Meet the requirements of IEC60601 series | ||||
Patient range | Adult, neonate and pediatric patients | ||||
Performance Specification | |||||
Display | 15' color TFT LCD screen, support external VGA(option). rolling and refreshing waveform display | ||||
Display mode | Standard, large font, NIBP trend, trend table, full lead ECG, Oxy CRG. | ||||
Interface | Parameter cable interface AC power input socket Network interface External VGA interface for connection of alternate display | ||||
Battery | 1 internal rechargeable lead-acid battery, 2.0Ah 12V | ||||
Alarm indicator | Visual on-display and integrated alarm light Audible alarm and personated voice reminding alarm | ||||
Data storage | 720 hours monitoring data 10000NIBP records storage 500 alarm event. | ||||
Printer | Built-in 50mm thermal printer (option), 3 traces, print speed 12.5mm/s &25mm/s & 50mm/s print width:50mm | ||||
Net working | Support connection to central monitoring station through LAN (TCP/IP) or wireless connection | ||||
ECG | |||||
Leads type | 3/5-lead : I, II, III, aVR, aVL, aVF, V | ||||
Sweep speed | 12.5mm/s, 25mm/s,50mm/s | ||||
Gain selection | x0.25,x0.5, x1, x2 | ||||
ECG waveform | 3 channels | ||||
Operation mode | Diagnostic, monitor, surgery | ||||
Heart rate range | 15 -350bpm | ||||
Accuracy | 1bpm or ±1% whichever is great | ||||
Alarm range | Audible and visual alarm, adjustable | ||||
ST/ arrhythmia | Real time S-T segment detection, pace detection and arrhythmia analysis | ||||
Protection | Against electrosurgical interference and defibrillation | ||||
Respiration (RESP) | |||||
Method | Thoracic impedance | ||||
Operation mode | Auto/manual | ||||
Measurement range | Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM | ||||
Apnea alarm | Yes | ||||
Alarm | Yes, audible and visual alarm ,alarm events recallable | ||||
NIBP | |||||
Method | Automatic oscillometric | ||||
Operation mode | Manual/Automatic/STAT | ||||
Auto measure time | Adjustable | ||||
Measurement unit | mmHg / kPa selectable | ||||
Test interval | 1-480 minutes | ||||
Measurement range | Adult: 0-300 mmHg ; Child: 0-240 mmHg ; Infant: 0-150 mmHg | ||||
Over-pressure protection | Double safety protection | ||||
Accuracy of blood pressure measurement | The mean error shall be less than±5mmHg the standard deviation shall be less than 8mmHG | ||||
Resolution | 1 mmHg | ||||
SpO2 | |||||
Measurement range | 0%-100% | ||||
Resolution | 1% | ||||
Accuracy | ±2% (70-100%, adult/pediatric, non-motion ) ±3% (70-100%, neonate, non-motion ) ±3% (70-100%, adult/pediatric/neonate, motion ) 0-69% unspecified | ||||
Alarm range | 1-100% | ||||
Pulse rate | Pulse range: | 0-350bpm | |||
Accuracy: | ±3bpm(non-motion) ±5bpm(motion ) | ||||
Temperature (TEMP) | |||||
TEMP range | 0-50degree | ||||
Resolution | 0.1 degree | ||||
Accuracy | ±0.1degree (excluding the sensor) | ||||
Channel | Dual-channel. provide T1;T2; | ||||
IBP | |||||
Measurement range | -50-360mmHg | ||||
Channel | 2 channels | ||||
Pressure transducer | Sensitive :5u V/V mmHg Impedance range :300-3000 Ω | ||||
Pressure names | ART,PA,CVP,RAP,LAP,ICP,P1,P2 | ||||
Alarm range | -10-300 mmHg | ||||
PR from IBP | Range & Accuracy: | 25-200bpm ±1bpm or ±1bpm which is greater 201-350bpm ±2% | |||
Resolution : | 1bpm | ||||
Depth of Anesthesia (BIS) | |||||
EEG sensitivity | +/- 475μV | ||||
Noise | < 2uVp-p (1-150 Hz) | ||||
CMRR | > 100 dB | ||||
Input impedance | > 50mohm | ||||
Sample rate | 1024 samples/s, 16 bits |