New Air Disinfector: UV-01 UV lamp power | 2*24W |
Power | 80W |
Way of control | Swith |
Size | 360*200*560mm |
Way of sterilization | Ozone free |
Gross Weight | 5.7kg |
Function | Sterilize,remove odor,kill mites,bacteria |
Voltage | 220V |
PRODUCT: UV air purifier (UV01)
RATED VOLTAGE: 230V/50Hz
REATED POWER: 120W
UV LAMP POWER: 80W
AIR FLOW: 380m³/h
MIN NOISE: 28dB(A)
Escherichia coli kill rate: 99%
UV LAMP STERILIZATION PRINCIPLE: Ultraviolet sterilization is the use of
appropriate wavelengths of ultraviolet rays to destroy the molecular structure of
DNA or RNA in microbial cells, causing growth cell death and/or regenerative cell
death to achieve the effect of disinfection. Based on modern epidemic prevention,
medicine and photodynamics, UV sterilization uses specially designed
high-efficiency, high-intensity and long-life UVC band ultraviolet light irradiation
to directly kill various bacteria, viruses, parasites, algae and other pathogens .
SERVICE LIFE - 6,000 hours
USE RANGE - Air sterilization for indoor or enclosed spaces
PRODUCT DESCRIPTION:
1. This product has the current leading filtration system and advanced air
purification and disinfection technologies such as ultraviolet lamp sterilization,
which can quickly and effectively remove inhalable particles, dust, bacteria,
viruses, etc. in the air, with a sterilization rate of 99 %, it has a good effect on
preventing influenza and cross infection.
2. This product is suitable for large rooms. It can be widely used in homes, hotels,
offices, small meeting rooms, entertainment rooms and other places. Five
purification modes, including high air volume and sleep, that allow you to have
the clean air no matter you are at work or in sleep.OPERATION INSTRUCTIONS
POWER BUTTON:
It is used to turn on and off. In the OFF state, press the the button to switch to
the state of the latest before the turning off or power failure (boot memory); in
the on state, press the button to turn off.
CHILD LOCK BUTTON:
Press and hold the child lock button for 5 seconds. After release, the child lock
indicator lights up and enters the state of child lock, all buttons are locked. It is
the same way to release the child lock.
AIR FLOW SPEED ADJUST BUTTON:
By pressing the air flow speed adjust button to cycle and switch the air flow
speed sequentially. The five speed is pollen, sleep, low, medium and high.
TIMING BUTTON:
Press the timing button to set the time from short to long. The three indicator
lights respectively represent 1 hour, 2 hours and 4 hours. The set automatic
on-off time is added according to the time represented by the light. It can be set
arbitrarily for 1-7 hours.
STERILIZATION BUTTON:
Press the button to turn on the operating of UV germicidal lamp or turn off.
DISPLAY
The display shows the room temperature under normal conditions.
When the UV lamp needs to be replaced, it will display '
88'
USE ENVIRONMENT
Do not use in ultra-high temperature environment
Be sure to keep the device upright when using the product.
Please keep a distance of 30 cm to 50 cm from the wall during use.4
MAINTENANCE KNOWLEDGE
The filter is a consumable item. Air purifiers rely on filters to filter
pollutants in the air. When the mesh of the filter is blocked by
contaminants, the filter must be replaced.
When the temperature display window displays double 8 characters, it
means that the UV lamp has reached the end of its service life and needs to be
replaced. After replacing the UV lamp, press and hold the UV sterilization button
for 5 seconds and then release, the reset is completed.
Machine storage method
Unplug the power cord when it will not be use for a long time, perform
maintenance, and then put it in a plastic bag and store it in a dry place.