China DTY-H220d75g Fully Isolated Single-Phase AC Voltage Regulator Module Pictures & Photosdty-H220d75g Fully Isolated Single-Phase AC Voltage Regulator Module, Find details about China Fully Isolated Single Phase AC Voltage Regulator, DTY-H220dd75g from DTY-H220d75g Fully Isolated Single-Phase AC Voltage Regulator Module Pictures & Photosdty-H220d75g Fully Isolated Single-Phase AC Voltage Regulator Module
Types of | Electric current | Choose one of 220V load last E\F\G\H | Choose one of the last E\F\G\H of 380V load |
Enhanced | 15A | DTY-H220D15E | DTY-H380D15E |
35A | DTY-H220D35E | DTY-H380D35E | |
55A | DTY-H220D55E | DTY-H380D55E | |
75A | DTY-H220D75E | DTY-H380D75E | |
120A | DTY-H220D120E | DTY-H380D120E | |
150A | DTY-H220D150E | DTY-H380D150E | |
190A | DTY-H220D190E | DTY-H380D190E | |
240A | DTY-H220D240E | DTY-H380D240E | |
290A | DTY-H220D290E | DTY-H380D290E | |
350A | DTY-H220D350E | DTY-H380D350E | |
normal type | 10A | DTY-220D10E | DTY-380D10E |
25A | DTY-220D25E | DTY-380D25E | |
40A | DTY-220D40E | DTY-380D40E | |
Half-wave | 10A | DTY-220D10XE | DTY-380D10XE |
25A | DTY-220D25XE | DTY-380D25XE | |
50A | DTY-220D50XE | DTY-380D50XE |
E series | F series | G series | H series | |
Input range | 0~5V | 0~10V | 4~20mA | 1~5V |
input resistance | >30KΩ | >30KΩ | 250Ω | >30KΩ |
Effective input range | 0.75~4.75V | 1.5~9.5V | 5~19mA | 1.25~4.75V |
Phase shift angle range | 150°~0° | 150°~0° | 150°~0° | 150°~0° |
Half-wave | Used for electric shock airport closure |
normal type | Small current module or dv/dt with lower requirements |
Enhanced | High current module or dv/dt demanding occasions |
220V | 220V loop load |
380V | 380V loop load (that is, add two live wires to the load) |
Current capacity selection | 1. For resistive loads, the current level of SSR should be greater than or equal to twice the rated current of the load. |
2.When the load is an AC motor, the current level of SSR must be greater than or equal to 6-7 times the rated current of the motor. | |
3. For AC electromagnet, intermediate relay wire protection, inductance coil and other loads, the current level of SSR should be greater than or equal to 4 times the rated load current. | |
4.When compensating for capacitor-type loads, the current level of SSR must be greater than 5 times the rated current of the load. | |
5. The transformer requires 5 times or more of the transformer primary rated current, and the special inductive and capacitive loads should also amplify the SSR current margin according to actual experience. |