China Power Generator 1125kVA 900kw Prime 1250kVA 1000kw Standby Power Power Generator Electric Diesel Generator Set, Find details about China Generator, Diesel Engine from Power Generator 1125kVA 900kw Prime 1250kVA 1000kw Standby Power Power Generator Electric Diesel Generator Set
MAMO series products are widely used in hospital, shipping, finance, communication, hotel, commerce, real estate, factory and many other important fields.The main supporting products include DEUTZ, Shangchai, Volvo, Doosan, Isuzu, Kubota, Yanmar, Jichai , Yuchai, Mecc Alte, Marathon and Stamford, etc.
MAMO supplying full ranges of Uk Diesel generator drive engines, covers 400 series, 1100 series, 1200 seris, 2206 series, 2806 series, 4000 series engines, electric engines comes with standard cooling pack, we also supply engine accessories including cooling system, air intake system, air exhaust system, control system.
Its reliable and durable diesel engine providing worldwide with a cost-effective and fully integrated electric Power product. Whether you need standby/emergency, continuous or prime power, with our engines, you can rest assured there's a electric product to fit your application.
Genset Main Technical Data: |
Genset Model | TC1250 | ||||||||||||||||||||||
Prime Power(50HZ) | 900KW / 1125KVA | ||||||||||||||||||||||
Standby Power(50HZ) | 1000KW / 1250KVA | ||||||||||||||||||||||
Frequency/Speed | 50Hz/1500rpm | ||||||||||||||||||||||
Standard Voltage | 400V/230V | ||||||||||||||||||||||
Phases | Three phases, four wires | ||||||||||||||||||||||
Manufacturer | MAMO POWER TECHNOLOGY CO., LTD. | ||||||||||||||||||||||
(1) PRP: Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO8528-1. A 10% overload capability is available for a period of 1 hour within 12-hour period of operation. In accordance with ISO 3046-1. (2) ESP: The Standby Power Rating is applicable for supplying emergency power in variable load applications for up to 200 hours per year in accordance with ISO8528-1. Overload is not allowed. | |||||||||||||||||||||||
Cummins Engine Data: | |||||||||||||||||||||||
Manufacturer | Cummins Engine Co. Ltd. | ||||||||||||||||||||||
Model | KTA38-G9 | ||||||||||||||||||||||
Engine speed | 1500rpm | ||||||||||||||||||||||
Engine power | |||||||||||||||||||||||
--------------------Standby power | 1090kw / 1460HP | ||||||||||||||||||||||
--------------------Prime power | 991kw / 1327 HP | ||||||||||||||||||||||
Type | 4 cycle, V, 12-cylinder | ||||||||||||||||||||||
Aspiration | Turbocharged | ||||||||||||||||||||||
Governor | Mechanical | ||||||||||||||||||||||
Bore * Stroke | 159*159 mm | ||||||||||||||||||||||
Displacement | 38L | ||||||||||||||||||||||
Compression ratio | 14.5:1 | ||||||||||||||||||||||
Governor Regulation: | ≤8% | ||||||||||||||||||||||
ALTERNATOR Specifications: | |||||||||||||||||||||||
Manufacturer | Cummins Generator Technologies(China) Co. Ltd | ||||||||||||||||||||||
Model | HCI 634K | ||||||||||||||||||||||
Output power | Prime:904kW 1130kVA / Standby:984kW 1230kVA | ||||||||||||||||||||||
AVR model | MX321 | ||||||||||||||||||||||
Number of phase | 3 | ||||||||||||||||||||||
Power factor (Cos Phi) | 0.8 | ||||||||||||||||||||||
Altitude | ≤ 1000 m | ||||||||||||||||||||||
Overspeed | 2250RPM | ||||||||||||||||||||||
Number of Pole | 4 | ||||||||||||||||||||||
Exciter type | Self exciting | ||||||||||||||||||||||
Insulation class | H | ||||||||||||||||||||||
Protection | IP23 | ||||||||||||||||||||||
Voltage regulation | ±1% | ||||||||||||||||||||||
Waveform distortion | no load < 1.5% non-distorting balanced linear load < 5.0% | ||||||||||||||||||||||
Telephone interference | THF< 2% | ||||||||||||||||||||||
Bearing | single | ||||||||||||||||||||||
Coupling | Direct |
Mamo POWER provides a full line of completely brand new and high quality products.
Each and every unit is strictly factory tested before shipment.
√ 1 Hour Testing
√ Fuel tank pressure testing
√ Parts faults testing
√ Bolt tightening torque testing
√ Painting thickness testing
√ Frequency & Voltage Testing
√ Automatic Start Testing
√ Routine Fault Alarm Testing
√ Downtime test
√ Noise testing
√ Loading Testing: 25%, 50%, 75%, 100%, 110% loading to check verify that all control systems, alarm and shut-down protection.
Standard Packing: Film plastic
Optional: Plywood Case
Delivery:
Approximately 2-4 weeks upon order confirmation
Mamo Power Technology Co.,Ltd (Mamo Power for short), High-Tech Enterprise, was established in 2004 and is located in forefront of West Strait Economic Zone, Fujian Province. Manufacturing base covers an area of 62000 square meters. Our power products cover diesel and gas gensets range from 5kva to 3300kva which are widely used in Ships, Financials, Telecom, Hospitals, Hotels, Real estates, Factories, Minings, Tunnels, High-ways and so on.
Container Genset in Austrailia Cooperating with Nishishiba Gensets used in Oil rig with Volvo Engines