Trxlpe 15kv Urd Concentric Neutral Cable LLDPE Jacket

China Trxlpe 15kv Urd Concentric Neutral Cable LLDPE Jacket, Find details about China Mv Cable, 15kv from Trxlpe 15kv Urd Concentric Neutral Cable LLDPE Jacket

Model NO.
MV-BE40
Wire Core Material
Round Aluminum or Copper Wire
Certification
ISO, CCC, CE, RoHS, UL, VDE
Model
Mv-Be40
Brand
Yifang
Standard
ASTM
Trademark
Yifang Cable
Transport Package
Wooden or Wooden-Steel Drum
Specification
2 AWG TO 4/0awg
Origin
Zhengzhou, China
HS Code
8544601200
Model NO.
MV-BE40
Wire Core Material
Round Aluminum or Copper Wire
Certification
ISO, CCC, CE, RoHS, UL, VDE
Model
Mv-Be40
Brand
Yifang
Standard
ASTM
Trademark
Yifang Cable
Transport Package
Wooden or Wooden-Steel Drum
Specification
2 AWG TO 4/0awg
Origin
Zhengzhou, China
HS Code
8544601200
TRXLPE 15kV Primary URD Concentric Neutral Cable LLDPE Jacket Copper Conductor

Applications

For use on single phase and three phase primary underground distribution systems operating at 15 kV phase to phase at 100 % insulation level. Suitable for either direct burial or installation in ducts.

Construction
Copper concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.

Standards
  • AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
  • ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000 V
  • ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors
  • ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
Options
  • EPR insulation
  • Filled strand
  • Cable core water blocking
Notes
  • Ampacities are based on the NEC.
  • Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105 ºC conductor, at an ambient temperature of 40 ºC.
  • Buried Duct: Three cables per duct operating at 105 ºC conductor, 20 ºC ground ambient, earth ρ = 90, 100 % load factor.
  • Conduit in Air: Three cables per isolated conduit in air at 40 ºC; operating at 105 ºC conductor (NEC Table 310.73).
  • Maximum conductor temperature: 90 ºC normal continuous, 130 ºC overload, 250 ºC short circuit.