Patient Monitor Medical Emergency Equipment Patient Monitor for ICU Use

China Patient Monitor Medical Emergency Equipment Patient Monitor for ICU Use, Find details about China Patient Monitor, Multi Parameter Patient Monitor from Patient Monitor Medical Emergency Equipment Patient Monitor for ICU Use

Model NO.
PM-200A
Standard Configuration
ECG,NIBP, SpO2, Pr, Resp, Temp, Hr
ECG
7 Lead ECG Waveform
Trademark
Dongjiang
Specification
39*37*30cm
Origin
Guangdong, China
HS Code
9018193010
Model NO.
PM-200A
Standard Configuration
ECG,NIBP, SpO2, Pr, Resp, Temp, Hr
ECG
7 Lead ECG Waveform
Trademark
Dongjiang
Specification
39*37*30cm
Origin
Guangdong, China
HS Code
9018193010
 
Product Description

Patient Monitor Medical Emergency Equipment Patient Monitor for ICU UsePatient Monitor Medical Emergency Equipment Patient Monitor for ICU UseFeatures
* 12.1 inch high brightness (800x600) colorful TFT LCD
* Simultaneous display of 7 lead ECG waveform  
* Indented menu layout to maximize the space for display        
* Protection agasint defibrillation and ESU interference 
* New SPO2 technology to assure precise measurement            
* Precise SPO2 measurement for low prefusion & finger motion                            
* Analysis of real time ST segment arrhythmia
* Able to analyze 15 kinds of drug level          
* 168 hour graphic and tabular trend with data storage
* High efficient power management without electric fan to avoid cross contamination  
* Up to 66 beds for networking capacity to connect with HIS
* 750 group NIBP data for recall and display 


* Standard configuration: ECG, NIBP, SpO2, PR, RESP., TEMP., HR, 
* Optional configuration: 1/2/4 IBP, EtCO2, multi gas, CO, 12 lead ECG, thermal recorder, touch screen, WiFi, HDMI, USB, VGA,                                                                         SunTech NIBP,Masimo/Nellcor SPO2 module

Product Parameters
Patient Monitor Medical Emergency Equipment Patient Monitor for ICU Use

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 3 channel
Gain:  2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, auto
HR and Alarm Range: Adult: 15 ~ 300 bpm, Neo/Ped: 15 ~ 350 bpm
Accuracy: ± 1% or ± 1 bpm, whichever greater
Resolution: 1 bpm
Sensitivity:  > 200 (uVp-p)
Differential Input Impedance:  > 5 MΩ
CMRR: Monitor: > 105 dB, Operation: > 105 dB, Diagnosis: > 85 dB
Electrode offset Potential: ± 300 mV
Leakage Current: < 10 uA
Baseline Recovery:  < 3 seconds after defibrillation
ECG Signal Range: ±8 mV (Vp-p)
Bandwidth:Surgery: 1 ~ 15 Hz, Monitor: 0.5 ~ 35 Hz, Diagnostic: 0.05 ~ 100 Hz
Calibration Signal:  1 (mVp-p), accuracy: ±5%
ST Segment Monitoring Range: Measure and Alarm: -2.0 ~ +2.0 mV
Alarm:  Available 
Review:  Available

SpO2

Measurement Range:  0 ~ 100 %
Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100%: ±2 %, 0% ~ 69%: unspecified
Actualization interval: about 1 second
 Alarm Delay:  10 second
 Pulse Rate Measurement and Alarm Range: 0 ~ 254 bpm
Resolution: 1 bpm
Accuracy: ± 2 bpm

Patient Monitor Medical Emergency Equipment Patient Monitor for ICU Use
Patient Monitor Medical Emergency Equipment Patient Monitor for ICU Use

NIBP

Method: Oscillometric
Mode: Manual, Auto, STAT
Measurement Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (minutes)
Measurement Period in STAT Mode: 5 minutes
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type:  SYS, DIA, MEAN
Measurement and Alarm Range
Adult Mode: SYS: 40 ~ 270 mmHg, DIA: 10 ~ 215 mmHg, MEAN: 20 ~ 235 mmHg
Pediatric Mode: SYS: 40 ~ 200 mmHg, DIA: 10 ~ 150 mmHg, MEAN: 20 ~ 165 mmHg
Neonatal Mode:  SYS: 40 ~ 135 mHg, DIA: 10 ~ 100 mmHg, MEAN: 20 ~ 110 mmHg
Resolution: Pressure: 1mmHg
Accuracy: Pressure
                  Maximum Mean error: ±5 mmHg
                  Maximum Standard deviation: ±8 mmHg
Overpressure Protection
    Adult Mode: 297 ± 3 mmHg
    Pediatric Mode: 240 ± 3 mmHg
    Neonatal Mode: 147 ± 3 mmH

Respiration

Method:  Impedance between R-F (RA-LL)
Differential Input Impedance:  >2.5 MΩ
Measurement Impedance Range:  0.3~5.0 Ω
Baseline Impedance Range: 0 - 2.5 KΩ
Bandwidth:  0.3 ~ 2.5 Hz
Resp. Rate
Measurement and Alarm Range: Adult: 0 ~ 120 rpm, Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy: ±2 rpm
Apean Alarm: 10 ~ 40 S
Patient Monitor Medical Emergency Equipment Patient Monitor for ICU Use
Patient Monitor Medical Emergency Equipment Patient Monitor for ICU Use

Temperature

Channel: 1
Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1 °C
Accuracy: ± 0.1 °C
Actualization interval:  about 1 second
Average Time Constant: < 10 second
Packaging & Shipping

Product dimension & weight
Length×Width×Height: 312mm×287mm×175mm
Weight: 3.4 Kg


Package list:
1* PM-200A Patient Monitor
1* ECG Cable(5 Lead)
1* ECG Electrodes
1* SpO2 Probe
1* NIBP Cuff
1*
Temp Probe
1* Extension tube
1* Power Wire
1* Grounding cable 
1* User manual 
1* Warranty
1* Certificate of Qualification

Packing: 1pc/carton, size: 39*37*30cm
Patient Monitor Medical Emergency Equipment Patient Monitor for ICU Use

Company Profile

Patient Monitor Medical Emergency Equipment Patient Monitor for ICU UsePatient Monitor Medical Emergency Equipment Patient Monitor for ICU UsePatient Monitor Medical Emergency Equipment Patient Monitor for ICU Use

Patient Monitor Medical Emergency Equipment Patient Monitor for ICU Use