Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller

China Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller, Find details about China Air Cooled Chiller, Chiller from Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller

Model NO.
ESGW series
Application Fields
Apartments
Application Machine
Cooling and Heating
Certification
CE
Condition
New
Inverter
Variable Frequency Drive
Compressor
Hanbell, Bitzer
Evaporator
Shell and Tube
Condenser
Shell and Tube
Hot Water
Heat Recovery Optional
Starter
Wye-Delta Starter
Controller
Touch Screen Microcomputer Control
Chiller Color
White
Expansion Valve
Danfoss, Emerson
Capacity Control
0, 50, 75, 100 for Single Compressor
Refrigerant
R22, R407c, R134A
Electrical Components
Schneider, FUJI
Sight Glass
Emerson
Service
OEM, ODM
Trademark
ESACIR
Transport Package
Wooden Pallet
Specification
Chilled water outlet temp.: 5~20C
Origin
Shenzhen
HS Code
8418692090
Model NO.
ESGW series
Application Fields
Apartments
Application Machine
Cooling and Heating
Certification
CE
Condition
New
Inverter
Variable Frequency Drive
Compressor
Hanbell, Bitzer
Evaporator
Shell and Tube
Condenser
Shell and Tube
Hot Water
Heat Recovery Optional
Starter
Wye-Delta Starter
Controller
Touch Screen Microcomputer Control
Chiller Color
White
Expansion Valve
Danfoss, Emerson
Capacity Control
0, 50, 75, 100 for Single Compressor
Refrigerant
R22, R407c, R134A
Electrical Components
Schneider, FUJI
Sight Glass
Emerson
Service
OEM, ODM
Trademark
ESACIR
Transport Package
Wooden Pallet
Specification
Chilled water outlet temp.: 5~20C
Origin
Shenzhen
HS Code
8418692090
Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller

1. Eurostars water cooled commercial screw chiller main components
(1)Compressor

A highly reliable semi-hermetic design, features simple and robust construction by elimination of some components such as pistons, piston rings, valve plates, oil pumps which are found in reciprocating compressors. Without these components,screw compressors run with low noise level, minimized vibration, high reliability and durability
(2)Evaporator
Dry type shell and tube heat exchanger with cooper tubes optimizes the cooling and heating efficiency. Self-cleaning, high intensity, anti-shaking design and heat insulation covering material ensure shell and tube heat exchanger unstained, reliable, quiet, highly efficient.
(3)Condenser
Shell and tube type condenser with copper tubes optimizes efficient heat exchange between the chiller and cooling tower.
(4)Throttling Device
Adopt superior quality famous exterior balanced thermal expansion valve, which is high reliability and adjustability, can realize precise refrigerant and temperature control to ensure operating in precise and reliable status.
(5)Intellectualized Controller
Adopt micro computer touch screen control, can operate via centralized manage system; whole system can realize remote operation. The system can monitor the water temperature, capacity status while running. The water temperature can be controlled according to the water outlet temperature. Trouble shooting code may display on the touch screen automatically when the system is abnormal.
(6)Heat Recover (Optional)
Shell and tube type heat recover with copper tubes which can reclaim the heat should discharge outside to produce domestic hot water,save cost.

Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller

2. VFD for Eurostars Chiller
Generally, as chillers spend most of their operating time at only 40 to 70 percent load, installing a VFD on the chiller and/or auxiliary equipment in hot, humid climates can produce energy savings. It's important to note that when there are multiple chillers, savings may be less with the amount of decrease depending on the control strategy employed. VFDs aren't recommended for chillers that operate predominantly at full load because they
can decrease a little chiller full-load efficiency.

Application considerations:
The cost-effectiveness of a VFD for a water-cooled chiller is affected by several factors. Applications where VFDs are more likely to be cost-effective include those with the following characteristics:
(1)Low chiller load factors.
In applications where chillers spend a lot of time at low loads, VFDs will save the most energy and have the best chance of a quick payback.
(2)Long cooling hours.
Facilities that long more annual cooling hours are able to recoup the cost of cooling system improvements more quickly than those with limited or seasonal operating hours, such as a school.
(3)Presence of multiple chillers.
Many facilities have two or more chillers that can be staged as load changes. This can create an ideal opportunity to install one or more VFD chillers to improve capacity control. Using a VFD on only one chiller allows you to more fully load the non-VFD chillers and use the VFD chiller to make up the difference in needed capacity. Using a VFD on all chillers in a plant allows you to balance run hours on all the equipment while still reaping the energy-efficiency benefits of VFDs.
(4)Presence of a building automation system.
Because VFD chiller plants can be operated in different ways, a building automation system can help building staff determine whether operating practices are helping or hindering overall plant efficiency.

 
3.Eurostars water cooled screw chiller construction diagram 
Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller

 
(1)Screw compressor(2)Motor wiring box(3)Electrical control box
(4)Control board(5)Discharge stop valve(6)Oil indicator
(7)Chilled water outlet(8)Suction pipe(9)Sight glass
(10)Evaporator(11)Condenser(12)Dry filter
(13)Angle valve(14)Expansion valve 

With heat recovery:
Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller
 
(1)Discharge stop valve(2)Electrical control box(3)Control board
(4)Heat recovery(5)Screw compressor(6)Suction pipe
(7)Expansion valve(8)Sight glass(9)Dry filter
(10)Evaporator(11)Condenser(12)Chilled water inlet

4. Eurostars central air conditioner system solution 
Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller

5. Eurostars water cooled commercial screw chiller brief technical data 
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Water Cooled Chiller Unit(R407C)
Model  ESGW   ~031SON041SON055SON067SON075SON089SON101SON108SON121SON141SON
Rated Cooling Capacity  KW96129166227248293339400473500
USRT27.3 36.7 47.2 64.6 70.5 83.3 96.4 113.8 134.5 142.2 
×1000kcal/h82.6 110.9 142.8 195.2 213.3 252.0 291.5 344.0 406.8 430.0 
Water Cooled Chiller Unit(R407C)
Model  ESGW   ~162SON175SON183SON208SON230SON234SON278SON297SON392SON443SON
Rated Cooling Capacity  KW553589616717787845943107413941587
USRT157.3 167.5 175.2 203.9 223.8 240.3 268.2 305.5 396.5 451.4 
×1000kcal/h475.6 506.5 529.8 616.6 676.8 726.7 811.0 923.6 1198.8 1364.8 
Water Cooled Chiller Unit(R407C)
Model  ESGW   ~062DON082DON110DON134DON150DON178DON202DON242DON282DON304DON
Rated Cooling Capacity  KW193257332454495587678800946999
USRT54.9 73.1 94.4 129.1 140.8 167.0 192.8 227.5 269.1 284.1 
×1000kcal/h166.0 221.0 285.5 390.4 425.7 504.8 583.1 688.0 813.6 859.1 
Water Cooled Chiller Unit(R407C)
Model  ESGW   ~324DON350DON366DON416DON460DON468DON556DON594DON784DON886DON
Rated Cooling Capacity  KW1105117812321433157416891885214827883174
USRT314.3 335.0 350.4 407.6 447.7 480.4 536.1 610.9 792.9 902.7 
×1000kcal/h950.3 1013.1 1059.5 1232.4 1353.6 1452.5 1621.1 1847.3 2397.7 2729.6 
Remarks:
(1)Rated Cooling Capacity Based on: Chilled water in/outlet temp. 12ºC/7ºC, Cooling water in/outlet temp. 30°C/35°C, Fouling factor: 0.088 sqm°C/KW.
(2) Chilled Water Range: 5~20ºC; Cooling Water Range: 20~40ºC;

6.Eurostars water cooled chiller series
Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller

 
Water cooled screw chiller(with dual compressors,dual condenser)
Water cooled screw chiller(with single compressor, single condenser)
Water cooled screw chiller(with flooded evaporator)
Water cooled screw chiller with heat recovery
Water cooled heat pump chiller
Water cooled heat pump chiller with heat recovery
Water cooled flooded screw chiller with heat recovery
Water cooled flooded heat pump chiller
Water cooled centrifugal water chiller

7.Six good reasons to use Eurostars chillers products
(1)Engineering
Save hours of engineering and fabrication time. From Eurostars you can get the right design, prudently engineered with quality components, and flexibility to suit your application.
(2)Maintenance
Eurostars designs and built for low maintenance. Save on the routine maintenance of competitive systems and reduce your chance of shutdowns. Your customized maintenance manual is clear and concise.
(3)Purchasing
You'll purchase a complete skid-mounted system customized by experts. It's headache-free one-stop purchasing.
(4)Support
Experts are available to answer your questions toll-free. We can offer advice on system flow, pressure and heat transfer requirements, equipment layouts, piping materials, and expanding a system to meet increased capacity, as well as trouble-shooting any existing installation.
(5)Installation
All necessary valves, controls and gauges can be pre-installed, so in-plant piping is streamlined. Running field wiring from the power supply and to remote fan motors typically completes the installation. A thorough, yet easy-to-read installation, operation and maintenance manual is prepared for each order.
(6)Price
Eurostars chillers are quality produced at an affordable price that can save you money for years to come. A real winner in terms of return on investment.

8. Why choose Eurostars Company?
(1)With more certificate
(2) Professional team with over more than 10 years industry knowledge
(3) Oversea installation.
(4) Customer-made accepted.
(5) Diamond member of Made-In-China
(6) Audited supplier by SGS

Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller
Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller

Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller

9. Our factory view

Modern new process and assemble line, including copper tube straighten machine, aluminum fin punching machine, three dimensional copper tube bending machine, tube expander machine, sheet metal laser cutting machine, numerical control punching machine, CNC bending machine, chiller, fan coil unit and AHU assemble line,. etc..
Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller

10. Eurostars water cooled chiller package and delivery

Our standard package is plastic film with wooden pallet for safe delivery and easy to load/unload.
Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller

11. Eurostars water cooled chiller projects

We exported chillers to Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway, Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..
Danfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled ChillerDanfoss VFD Chiller Commerical Air Cooled Chiller Water Cooled Chiller