China Low Freqeuncy Online UPS, 30kVA, Find details about China Ups, Online Ups from Low Freqeuncy Online UPS, 30kVA
2K~20K (1-in/1-out) | |||||||||||||||||||
Model | 2K | 3K | 6K | 10K | 15K | 20K | |||||||||||||
Capacity (VA/W) | 2K/1.6K | 3K/2.4K | 6K/4.8K | 10K/8K | 15K/12K | 20K/16K | |||||||||||||
Input voltage | 220V±25%, 1-phase/3-wire | ||||||||||||||||||
Noise | ≤52dB (distance: 1m) | ≤55dB(distance: 1m) | |||||||||||||||||
Sizes (W×D×H,mm) | 530×240×592 | 624×343×760 | |||||||||||||||||
Weight (Kg) (w/o battery ) | 35 | 35 | 53 | 91 | 110 | 122 | |||||||||||||
6K3~60K3(3-in/1-out) | |||||||||||||||||||
Model | 6K 3-1 | 10K 3-1 | 15K 3-1 | 20K 3-1 | 30K 3-1 | 40K 3-1 | 50K 3-1 | 60K 3-1 | |||||||||||
Capacity (VA/W) | 6K/4.8K | 10K/8K | 15K/12K | 20K/16K | 30K/24K | 40K/32K | 50K/40K | 60K/48K | |||||||||||
Input voltage | 380V±25%, 3-phase/5-wire | ||||||||||||||||||
Noise | ≤55dB(distance: 1m) | ≤60dB(distance: 1m) | |||||||||||||||||
Sizes (W×D×H,mm) | 530×240×592 |
624×343×1020 |
624×480×1100 | ||||||||||||||||
Weight (Kg) (w/o battery ) | 53 | 139 | 158 | 178 | 263 | 335 | 400 | 480 | |||||||||||
Common parameter | |||||||||||||||||||
Input | Frequency | 50Hz/60Hz±10% | |||||||||||||||||
Power factor | ≥92% | ||||||||||||||||||
Output | Voltage | 220V±0.5% | |||||||||||||||||
Voltage regulation | ±1% (static); ±2% (dynamic) (20ms from 0-100% load change) | ||||||||||||||||||
Frequency regulation | 50Hz/60Hz±0.05%(on battery mode) | ||||||||||||||||||
Frequency tracking rate | <1Hz/s | ||||||||||||||||||
Dynamic response | ±0.4%(100% load change) | ||||||||||||||||||
THD | <3% @ linear load (full load); <5% @ non-linear load (full load) | ||||||||||||||||||
Waveform | True sine wave | ||||||||||||||||||
Efficiency | AC input to AC output | ≥91% | |||||||||||||||||
Transfer time | Mains fails or restores | 0s | |||||||||||||||||
Battery | Voltage | 192V for 2K to 20K ; 336V for 30K to 60K | |||||||||||||||||
Charge time | 8 hours to 90% | ||||||||||||||||||
Alarm | Battery discharge | Beeps every four (4) seconds when AC mains fails | |||||||||||||||||
Beep every one (1) second when battery voltage low | |||||||||||||||||||
Continuously beeps when stopping battery discharge | |||||||||||||||||||
Fault | Continuously beeps | ||||||||||||||||||
Protection & Display | Battery | Automatically shutdown when battery low, no fuse switch protection. | |||||||||||||||||
Overload | Automatically jumps to BYPSS when 110~150% overload for 30 seconds and automatically resumes when overload removed. | ||||||||||||||||||
Over temperature | Automatically jump to BYPSS when UPS internal temperature >85ºC , | ||||||||||||||||||
Short circuit | Current limit, automatic shutdown, fuse and no fuse switch protection | ||||||||||||||||||
UPS abnormal | Automatically jumps to BYPASS | ||||||||||||||||||
Noise filter | 10~10KHz at 40 db;100KHz~100MHz at 70db | ||||||||||||||||||
LCD display | Display input voltage/frequency, battery voltage and output power (%) | ||||||||||||||||||
Environment | Temperature | -10~40ºC | |||||||||||||||||
Relative humidity | 10%~90%(no condensation) | ||||||||||||||||||
Altitude | 1500m |