Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply

China Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply, Find details about China Insulation Fault Locator, Medical Insulation Fault Locator from Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply

Model NO.
AIL150-8
Locating Circuits
8 Circuits,Max up to 24 Circuits
Communication
Can
Trademark
ACREL
Transport Package
Paper Carton
Specification
0.5kgs
Origin
Jiangsu, China
HS Code
9031809090
Model NO.
AIL150-8
Locating Circuits
8 Circuits,Max up to 24 Circuits
Communication
Can
Trademark
ACREL
Transport Package
Paper Carton
Specification
0.5kgs
Origin
Jiangsu, China
HS Code
9031809090
Product Description
 

Medical insulation fault locator for hospital equal to Bender EDS440

It can detect ASG150 test signal generator' s signal which is injected into the system,It can accurately locate the insulation fault circuit. AIL 150-8

insulation fault locator can locate 8 channel insulation fault locations,3 pcs AIL150-8 can be used in 1 hospital isolated power system to locate up to

24 circuit fault locations.


Functions and Parameters

parameters of 24 circuit hospital medical insulation fault

locator :


*Insulation fault location in medical IT system
 
*8 circuit fault location used with test signal generator
 
*Up to 24 circuit fault locations in 1 hospital power supply
 
*Power supply:DC24V
 
*Communication:CAN
 
*With communication end matching resistor function
Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply

Parameter
Values
AIL150-4
AIL150-8
Auxiliary power
Voltage
DC24V(±25%)
The maximum power consumption
≤2VA
Monitored system
Rated voltage
0-242VDC
Frequency
45-60HZ
Location signals
Location voltage
<25V
Location current
<1mA
Fault location
the maximum number of loops
4
8
Response time
<2S
Communication
Bus
CAN
Protocol
Custom protocol

Remark:the medical fault locator can locate up to 24 circuits in the same hospital power system

Dimensions and Wirings
Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply

Solutions and Applications

Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply
Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply
name
model
Insulation monitor
AIM-M200
Power module
DR-60-24
Isolation transformer
AITR8000
Current Transformer
AKH-0.66P26
test signal generator
ASG150
insulation fault locator
AIL150-4
centralized remote alarm indicator
AID150
instructions:For the method of the isolation power supply system in the operating room and the intensive care room, please refer to Acrel isolation power supply monitoring system design and application Atlas" and product selection manual.