Cjx9 Series 20A 25A 30A 32A 40A 1p 2p 3p 4p Contactor Air Conditioning Contactor Magnetic

China Cjx9 Series 20A 25A 30A 32A 40A 1p 2p 3p 4p Contactor Air Conditioning Contactor Magnetic, Find details about China Air Conditioning Contactor, Contactor from Cjx9 Series 20A 25A 30A 32A 40A 1p 2p 3p 4p Contactor Air Conditioning Contactor Magnetic

Model NO.
CJX9
Standard
IEC 60947-1
Coil Voltage
24,220,240,380,415V
Rated Current
20,30,40,50,65,75,90A
Frequency
50Hz/60Hz
Pole
1p2p3p
Trademark
SONTUOEC, WZSTEC
Transport Package
Exporting Carton with Pallets
Specification
100PCS/CTN
Origin
China
HS Code
8536900000
Model NO.
CJX9
Standard
IEC 60947-1
Coil Voltage
24,220,240,380,415V
Rated Current
20,30,40,50,65,75,90A
Frequency
50Hz/60Hz
Pole
1p2p3p
Trademark
SONTUOEC, WZSTEC
Transport Package
Exporting Carton with Pallets
Specification
100PCS/CTN
Origin
China
HS Code
8536900000
CJX9 Series 20A 25A 30A 32A 40A 1P 2P 3P 4P contactor Air conditioning contactor magnetic

1P,2P,3P,4POLE Air Condition CONTACTORS (20A THRU 90A) Designed for Air Conditioning and Heating Equipment FEATURES .low VA coil for cooler operation and increased life .Quiet operation .Universal style mounting bracket existing mounting holes .Double brake contacts ensure positive make and break .Screw terminal or pressure connectors and double 1/4 quick connects provided on all models for easy installation
 
Specifications
 
Insulating material
contact block and carrier are highly electrical-grade thermosetting resin
Temperature range
-40°F to 150°F
mechanical life
conforms to UL and ARI specifications
electrical life
conforms to UL and ARI specifications 94-388 thru 94-390 achieve 200,000 Cycles,make LRA at.5pf, break 125% of FLA at. 75pf at rated voltage,10,000 cycles make and brek LRA at.5pf rated voltage 94-394 thru 94-369 achieve 100,000 cycles, make LAR at 5pf at rated voltage 6.000 cycles make and break LEA at 5pf rated voltage
outline drawings
as follow
weight(approximate)
9.5oz
coils frenquency
50/60hz
coils insulation
class B(130'C)
termination
pressure connector and double 1/4 Q.C.
operate
85% of nominal coil voltage, 110% maximum sate operate
duty cycle
continuous
Steveco nmuber
Volatge
Ress DC
Current
Nominal
Max. Inrush
30 Amp 40Amp
AC
OHMS
MA
VA
VA
C2-244 C2-247
24
11
250
6
32
C2-389 C2-395
120
224
50
6
32
C2-390 C2-396
208/240
997
25
6
32
Contact Ratings
Type
Voltage
FLA
LRA
RES
C2-244 thru C2-246
277
30
150
40
480
30
75
40
600
30
50
40
C2-3247 thru C2-252
277
40
200
50
480
40
100
50
600
40
80
50
Cjx9 Series 20A 25A 30A 32A 40A 1p 2p 3p 4p Contactor Air Conditioning Contactor Magnetic



Cjx9 Series 20A 25A 30A 32A 40A 1p 2p 3p 4p Contactor Air Conditioning Contactor Magnetic

Cjx9 Series 20A 25A 30A 32A 40A 1p 2p 3p 4p Contactor Air Conditioning Contactor Magnetic
Cjx9 Series 20A 25A 30A 32A 40A 1p 2p 3p 4p Contactor Air Conditioning Contactor Magnetic