2000kVA Reactive Load Bank for Generator Testing Power Factor 0.8-1

China 2000kVA Reactive Load Bank for Generator Testing Power Factor 0.8-1, Find details about China Load Bank, 2000kVA Load Bank from 2000kVA Reactive Load Bank for Generator Testing Power Factor 0.8-1

Model NO.
AC415-2000KVA
Power Source
AC415
Voltage
415VAC 50Hz
Power
2000kVA
Power Factor
0.8-1
Protection
IP55
Work Place
Outdoor
Trademark
TriumphLoad
Transport Package
Container
Origin
China
Model NO.
AC415-2000KVA
Power Source
AC415
Voltage
415VAC 50Hz
Power
2000kVA
Power Factor
0.8-1
Protection
IP55
Work Place
Outdoor
Trademark
TriumphLoad
Transport Package
Container
Origin
China

2000KVA Reactive Load Bank for Generator Testing 


2.1 Measuring Function

Steady-state Test: load power in rated range, measure generator steady-state 3 phase voltage, current, active power, reactive power, apparent power, power factor, frequency, and running time.

2.2 Control Mode

(1) Control Mode: local, remote or intelligent control(software) for choosing.

(2) Local Control: local control panel with several power steps, load or unload by switch on-off and read parameter values from measuring meter.

(3) Remote Control:through the switch in the remote control box, control the load over a long distance.

(4) Intelligent Control: through data processing software, realize all the test functions, display, record and manage the testing data, and generate curves, graphs and tables can be printed.

(5) Control Mode Interlock: with control mode switch, no matter chooses which mode, operation of other mode is invalid, avoid the clash.

2.3 Intelligent Load Function

(1) Communication Mode: using photoelectric isolated RS485 communication serial port connect to PC, and with great anti-interference performance to make system control stable. Through converts like USB or RS232 realize communication protocol conversion.

(2) Load Mode: steady-state load (manual load, preset load and automatic load) and transient state load (instant load and instant unload).

(3) Manual Load: input power and power factor, and load according to the preset value.

(4) Preset Load: input generator related parameters, then choose the preset proportion from 0% 25%, 50%, 75%, 100% or other available order and calculate the power value automatically and realize rapid load.

(5) Automatic Load: set several load stages and duration, then complete the process according this stages automatically. Pause at any time or start to next stage in the load process.

(6) Parallel Test: several load banks work in parallel, the parallel test via software. Parameters of each set can be displayed in each meter and total parameter values can be displayed and recorded.

2.4 Data Manage Function

(1) Real-time Monitor: through software display main parameter value, such as voltage, current, power, power factor, frequency and time.

(2) Data Collection Interval: the minimum steady-state data resolving time is 1 second, and the minimum transient data resolving time is 40μs.

(3) Stable Data Comparisons: the max value and min value of all the parameters in steady-state test are listed in software interface; it is convenient for user to compare.

(4) Data Save and Query: all test data are saved in the software, and according to generator set number easy to fast query in the history test data.

(5) Graphical Display: show real-time or history test data, and support to print curve and graph as follows:

1) Voltage, current, frequency and power curves in real-time; 2) voltage curve;

3) Current curve; 4) power curve; 5) frequency curve; 6) power factor curve;

(6) Test Report: display and support to print reports as follow:

1)Test report of generator set steady-state performance; 2)testing data report

(7) Data Format: all curves and graphs are outputted as".jpg"format, testing reports are outputted as".xls"format, and can be printed.

 

2.5 Protection

(1) Overvoltage Protection: the input load voltage is over the safe threshold value, system unload automatically and give an alarm.

(2) Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.

(3) Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.

(4) Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.

(5) Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.

(6) Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.

(7) Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.

2.6 Technical Parameter

System Parameter

Rating voltage/frequency

400V, 3 phase 4 wire 50Hz

Max Load Power

Apparent Power: 2000KVA

Resistive Load: 1600kW

Inductive Load: 1200KVAR

Load Resolution

Resistive Load: 16 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,200kW,200kW,200kW, 200kW,200kW,200kW,200kW

Inductive Load: 14 steps 

1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR

Power Factor

0.6(lag)

Load Tolerance (each step)

±5%

Load Tolerance (overall)

±3%

Fan &Control Voltage

External AC 3 phase 4 wire, 380V/50Hz 

Wire Connection

Load bank input--Copper bar (star coupling "Y")

Control power input--Connector-bar

Communication Interface

RS485,RS232

Insulation

F

Max Protection Grade

IP55

Duty Cycle

Continuous  

Cooling

Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling

Enclosure

Container type, with a ladder, air inlet and outlet with mesh enclosure and protection door

Internal Lighting

Adequate internal lighting will be provided

Transportation

Hoisting, there are lifting lug in top of casing

Color

Grey RAL7035 or as required

Dimensions

About 4000mm×2350mm×2591mm(L×W×H)

Weight

Around 7900kg

Operating Environment Parameter

Workplace

 Outdoor 

Ambient Temperature

-10ºC~+50ºC

Relative Humidity

≤95%

Atmospheric Pressure

86~106kPa

Brands of Main Components

Contactor

  Schneider

Fuse

 Miro

PLC

 Siemens

Alloy Resistor

  Kaixiang

Data Processing Software

 Kaixiang


Contact us

Hebei Kaixiang Electrical Technology Co., Ltd       
          James Lee
        Sales   Manager
 
No 79 Wangshan Road, Shijiazhuang City, 
Hebei Province, China
 
 
kxload.en.made-in-china.com