China 1200W Programmable High Voltage DC Source Power Supply, Find details about China Programmable DC Source, Programmable Power Supply from 1200W Programmable High Voltage DC Source Power Supply
1.Battery fluctuation simulation test
2.Battery charger
3.High voltage diode
4.Electrolytic capacitor
5.Electromechanical control and ATE test system
Main Features
*Voltage up to 1000VModel | N3608-080-060 | N3612-080-060 | N3612-240-030 | N3618-016-250 | N3618-080-120 |
Voltage | 0-80V | 0-80V | 0-240V | 0-16V | 0-80V |
Current | 0-60A | 0-60A | 0-30A | 0-250A | 0-120A |
Power | 800W | 1200W | 1200W | 1800W | 1800W |
CV Mode | |||||
Range | 0-80V | 0-80V | 0-240V | 0-16V | 0-80V |
Setting Resolution | 1mV | 1mV | 10mV | 1mV | 1mV |
Setting Accuracy (23±5ºC) | 0.05%+0.05%F.S. | ||||
CC Mode | |||||
Range | 0-60A | 0-60A | 0-30A | 0-250A | 0-120A |
Setting Resolution | 1mA | 1mA | 1mA | 10mA | 10mA |
Setting Accuracy (23±5ºC) | 0.1%+0.1%F.S. | ||||
Voltage Measurement | |||||
Range | 0-80V | 0-80V | 0-240V | 0-16V | 0-80V |
Readback Resolution | 1mV | 1mV | 10mV | 1mV | 1mV |
Readback Accuracy (23±5ºC) | 0.05%+0.05%F.S. | ||||
Temperature Coefficient | 50ppm/ºC | ||||
Current Measurement | |||||
Range | 0-60A | 0-60A | 0-30A | 0-250A | 0-120A |
Readback Resolution | 1mA | 1mA | 1mA | 10mA | 10mA |
Readback Accuracy (23±5ºC) | 0.1%+0.1%F.S. | ||||
Temperature Coefficient | 50ppm/ºC | ||||
Line Regulation | |||||
Voltage | ≤0.01% | ||||
Current | ≤0.05% | ||||
Load Regulation | |||||
Voltage | ≤0.05% | ||||
Current | ≤0.05% | ||||
Dynamic Characteristics | |||||
Voltage Rise Time (no load) | ≤20ms | ≤20ms | ≤60ms | ≤10ms | ≤20ms |
Voltage Rise Time (full load) | ≤500ms | ≤300ms | ≤500ms | ||
Voltage Fall Time (no load) | ≤700ms | ≤700ms | ≤300ms | ≤50ms | ≤700ms |
Voltage Fall Time (full load) | ≤20ms | ≤20ms | ≤50ms | ≤5ms | ≤20ms |
Transient Recovery Time | The recovery time of load varying from 10% to 90% and output voltage recovering within 0.5% of rated voltage is less than 20ms. | ≤80ms | ≤20ms | ||
Output Ripple(20Hz-20MHz) | |||||
Voltage Ripple (P-P) | ≤300mVp-p | ≤300mVp-p | ≤400mVp-p | ≤400mVp-p | ≤400mVp-p |
Others | |||||
Efficiency | 90%(Typical) | ||||
Interface | RS232/LAN | ||||
Communication Response Time | ≤5ms | ||||
AC Input | Single phase, please refer to the voltage mark at the rear panel. | ||||
Temperature | Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC | ||||
Operating Environment | Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa | ||||
Net Weight | Approx. 15.5kg | 16.5kg | 18kg | ||
Dimension | 2U, 88.0(H)*482.0(W)*550.0(D)mm |