China Lab Use Programmable Adjustable DC Power Supply 0-3000W 0-600V 0-20A, Find details about China Programmable DC Source, Programmable Power Supply from Lab Use Programmable Adjustable DC Power Supply 0-3000W 0-600V 0-20A
1.Battery fluctuation simulation test
2.Battery charger
3.High voltage diode
4.Electrolytic capacitor
5.Electromechanical control and ATE test system
Main Features
*Voltage up to 1000VModel | N3608-080-060 | N3612-080-060 | N3612-240-030 | N3618-016-250 | N3618-080-120 |
Voltage | 0-80V | 0-80V | 0-240V | 0-16V | 0-80V |
Current | 0-60A | 0-60A | 0-30A | 0-250A | 0-120A |
Power | 800W | 1200W | 1200W | 1800W | 1800W |
CV Mode | |||||
Range | 0-80V | 0-80V | 0-240V | 0-16V | 0-80V |
Setting Resolution | 1mV | 1mV | 10mV | 1mV | 1mV |
Setting Accuracy (23±5ºC) | 0.05%+0.05%F.S. | ||||
CC Mode | |||||
Range | 0-60A | 0-60A | 0-30A | 0-250A | 0-120A |
Setting Resolution | 1mA | 1mA | 1mA | 10mA | 10mA |
Setting Accuracy (23±5ºC) | 0.1%+0.1%F.S. | ||||
Voltage Measurement | |||||
Range | 0-80V | 0-80V | 0-240V | 0-16V | 0-80V |
Readback Resolution | 1mV | 1mV | 10mV | 1mV | 1mV |
Readback Accuracy (23±5ºC) | 0.05%+0.05%F.S. | ||||
Temperature Coefficient | 50ppm/ºC | ||||
Current Measurement | |||||
Range | 0-60A | 0-60A | 0-30A | 0-250A | 0-120A |
Readback Resolution | 1mA | 1mA | 1mA | 10mA | 10mA |
Readback Accuracy (23±5ºC) | 0.1%+0.1%F.S. | ||||
Temperature Coefficient | 50ppm/ºC | ||||
Line Regulation | |||||
Voltage | ≤0.01% | ||||
Current | ≤0.05% | ||||
Load Regulation | |||||
Voltage | ≤0.05% | ||||
Current | ≤0.05% | ||||
Dynamic Characteristics | |||||
Voltage Rise Time (no load) | ≤20ms | ≤20ms | ≤60ms | ≤10ms | ≤20ms |
Voltage Rise Time (full load) | ≤500ms | ≤300ms | ≤500ms | ||
Voltage Fall Time (no load) | ≤700ms | ≤700ms | ≤300ms | ≤50ms | ≤700ms |
Voltage Fall Time (full load) | ≤20ms | ≤20ms | ≤50ms | ≤5ms | ≤20ms |
Transient Recovery Time | The recovery time of load varying from 10% to 90% and output voltage recovering within 0.5% of rated voltage is less than 20ms. | ≤80ms | ≤20ms | ||
Output Ripple(20Hz-20MHz) | |||||
Voltage Ripple (P-P) | ≤300mVp-p | ≤300mVp-p | ≤400mVp-p | ≤400mVp-p | ≤400mVp-p |
Others | |||||
Efficiency | 90%(Typical) | ||||
Interface | RS232/LAN | ||||
Communication Response Time | ≤5ms | ||||
AC Input | Single phase, please refer to the voltage mark at the rear panel. | ||||
Temperature | Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC | ||||
Operating Environment | Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa | ||||
Net Weight | Approx. 15.5kg | 16.5kg | 18kg | ||
Dimension | 2U, 88.0(H)*482.0(W)*550.0(D)mm |