China Ultrafiltration Hollow Fiber UF Membrane Module for Water Treatment Plant, Find details about China Fouling-Resistant Membrane, Water Filter from Ultrafiltration Hollow Fiber UF Membrane Module for Water Treatment Plant
Product Code | Module Type | A (mm) | B (mm) | C (mm) | L1(mm) |
UF-4040 | UF-4040 | 101 | 19 | 27 | 1016 |
Product Code | Module Type | A (mm) | B (mm) | C (mm) | L1(mm) | L2(mm) |
UF-4046 | UF-4046 | 169 | 113 | 112.5 | 965 | 1155 |
Product Code | Module Type | A (mm) | B (mm) | C (mm) | L1(mm) | L2(mm) |
UF-6060 | UF-6060 | 195 | 160 | 160 | 1132 | 1352 |
Product Code | Module Type | A (mm) | B (mm) | C (mm) | L1(mm) | L2(mm) |
UF-8060 | UF-8060 | 320 | 237 | 183.5 | 1020 | 1415 |
Product Code | Module Type | A (mm) | B (mm) | C (mm) | L1(mm) | L2(mm) |
UF-1060 | UF-1060 | 323 | 303 | 173 | 1600 | 1713 |
Module | UF-4040 | UF-4046 | UF-6060 | UF-8060 | UF-1060 |
Module type | Inside-out | Inside-out | Inside-out | Inside-out | Inside-out |
Shell and seal materials | PVC,epoxy resins | PVC,epoxy resins | PVC,epoxy resins | PVC,epoxy resins | PVC,epoxy resins |
Membrane Material | PAN/PVC | PAN/PVC | PAN/PVC | PAN/PVC | PAN/PVC |
Molecular Weight Cut off(Dalton) | 50.000 | 50.000 | 100.000 | 100.000 | 100.000 |
Size (mm) | Ø90×1016 | Ø90×1155 | Ø160×1352 | Ø200×1415 | Ø250×1713 |
Effective membrane area | 4m2 | 4.8m2 | 15m2 | 25m2 | 52m2 |
Hollow fiber id/od size | 1.0mm/1.6mm | 1.0mm/1.6mm | 1.0mm/1.6mm | 1.0mm/1.6mm | 1.0mm/1.6mm |
Max operating pressure | 0.3Mpa | 0.3Mpa | 0.3Mpa | 0.3Mpa | 0.3Mpa |
Suggest operating pressure | <0.2Mpa | <0.2Mpa | <0.2Mpa | <0.2Mpa | <0.2Mpa |
Max transmembrane pressure | <0.2Mpa | <0.2Mpa | <0.2Mpa | <0.2Mpa | <0.2Mpa |
Backwash pressure | 0.05-0.1Mpa | 0.05-0.1Mpa | 0.05-0.1Mpa | 0.05-0.1Mpa | 0.05-0.1Mpa |
Produced water pollution index( SDI 25) | <3 | <3 | <1 | <3 | <3 |
Initial flux | 0.8m3/h | 1.0m3/h | 4.5m3/h | 5m3/h | 9m3/h |
Design flux | 40-150L/m2/h | 40-150L/m2/h | 40-150L/m2/h | 40-150L/m2/h | 40-150L/m2/h |
Operating mode | Cross flow or dead-end flow | Cross flow or dead-end flow | Cross flow or dead-end flow | Cross flow or dead-end flow | Cross flow or dead-end flow |
Bacteria removal rate | >4log | >4log | >6log | >6log | >6log |
Permeate turbidity | <0.1NTU | <0.1NTU | <0.1NTU | <0.1NTU | <0.1NTU |
Operating temperature | 5~40ºC | 5~40ºC | 5~40ºC | 5~40ºC | 5~40ºC |
PH range | 2~10 | 2~10 | 2~10 | 2~10 | 2~10 |
UF2880 | Filtration Type | Outside-In |
Max. Working Pressure (@ 20ºC) | 94 psi (0.62MPa / 6.25bar) | |
Suggested Working Pressure | 43 psi (0.3MPa / 3bar) | |
Backwash pressure(suggested) | 36 psi (0.25Mpa /2.5bar ) | |
Air Flush Rate(Duration 2~4mins)(suggested) | 7~9 acfm (12~15m3/h) | |
Max. Trans-Membrane Pressure Drop(TMP) | 30 psi (0.2MPa / 2bar) | |
Feed Water Temperature | 1~40ºC | |
Active Membrane Area | 77 m2(829ft2) | |
Filtrate Water Flow Range | 13~40 GPM (3~9M3PH) | |
Molecular Weight Cut-Off /MWCO/(average porosity/pore Ø) | 100,000 Dalton (0.01µm~0.1 µm) | |
Hollow Fiber Tubes In/Out Diameter | 0.6/1.2mm | |
pH Range of Feed Water During Continuous Operation | 2~11 | |
Operation Mode | Cross flow/Dead-end flow | |
Max Feed Water Turbidity | < 300 NTU | |
Product Water Turbidity | <0. 1 NTU | |
Feed Water Particle size (max.) | < 300 µ | |
Feed Water SDI15 | < 25 | |
Product Water SDI15 | < 2.5 | |
Product water average flow in system(Suggested) | Approximately 3M3PH |
UUF2860 | Filtration Type | Outside-In |
Max. Working Pressure (@ 20ºC) | 94 psi (0.62MPa / 6.25bar) | |
Suggested Working Pressure | 43 psi (0.3MPa / 3bar) | |
Backwash pressure(suggested) | 36 psi (0.25Mpa /2.5bar ) | |
Air Flush Rate(Duration 2~4mins)(suggested) | 7~9 acfm (12~15m3/h) | |
Max. Trans-Membrane Pressure Drop(TMP) | 30 psi (0.2MPa / 2bar) | |
Feed Water Temperature | 1~40ºC | |
Active Membrane Area | 55 m2(592ft2) | |
Filtrate Water Flow Range | 9~27 GPM (2~6M3PH) | |
Molecular Weight Cut-Off /MWCO/(average porosity/pore Ø) | 100,000 Dalton (0.01µm~0.1 µm) | |
Hollow Fiber Tubes In/Out Diameter | 0.6/1.2mm | |
pH Range of Feed Water During Continuous Operation | 2~11 | |
Operation Mode | Cross flow/Dead-end flow | |
Max Feed Water Turbidity | < 300 NTU | |
Product Water Turbidity | <0. 1 NTU | |
Feed Water Particle size (max.) | < 300 µ | |
Feed Water SDI15 | < 25 | |
Product Water SDI15 | < 2.5 | |
Product water average flow in system(Suggested) | Approximately 2.5M3PH |
MODEL | L | L1 | L2 | L3 | D | In/out Ø |
UF2860 | 1860 mm (73'') | 1500 mm (59'') | 1630mm (64'') | 1820 mm (72'') | 225mm (9'') | DN50 mm (2'') |
UF2880 | 2360 mm (93'') | 2000 mm (79'') | 2130mm (84'') | 2320 mm (91'') | 225mm (9'') | DN50 mm (2'') |