Safety Instruction
Related part should be operated under low voltage condition. All installation process and maintaince be carried out by the supplier.
Name of Related Parts
▪JST connection( Red:24V power cable; Yellow: Relay )
▪COM / NO
▪The indicator will shin for few seconds when starting. When object is detected by sensor, indicator lights up.
▪Sensitivity potentiometer
▪Fluctuation up and down, rotation left and right.
Installation
1.Please do the installation in the proper position, installation height within 3.5m. Please arrange hole (Φ3.2mm) on the installation module. And hole (Φ12m) for insetting guide line.
2.Please connect the signal cable with the terminal of automatic door.
Brown and Yellow cable: AC/DC 12-24V
Green and White cable: Signal output COM/NO
3.Take the outer cover off, and fix the screws.
4.Finish the cable connection and get on power.
5.Please set the detection range and disjunctor accordingly.
6.Cover with the lid.
Picture of Automatic Sliding Doors Detecting Sensor
Adjustment ( Get on Power )
1.Detection range
Note: Please stand out of the detection range around 5s to ensure the sensor has enough time to finish the self-adjustment.
2.Sensitivity adjustment
Detection range
MIN: 0.5*0.4M
MAX: 4*2M
Select different detection range by adjusting sensitivity knob
3.Adjustment of detection
( Adjust Direction of front and back / Left and Right flexibly )
Adjusting angle of plain aerial to get different detection distance range 30=15×2range
NOTE:
Initial setting is 45 degree by factory.
All the parameters above are only for reference, detection height is 2.2M.
Detection range will be different because of the making material of door and groud, please adjust the sensitivity by the knob metioned above.
When it is adjusted to 60 degree, the detection range is the widest, door will keep on closed and open all the time.
Special Note
▪Position should be fixed tightly to avoid virbrating.
▪Do not place into board or other material.
▪Moving object should be avoided.
▪Fluorescent should be avoided.
▪Do not touch directly, ESD protection is necessary.
Failure Cause
Symptom | Cause | Method |
Door&indicator lose failure | Did not get power | Check cable connection&power supply |
Door keep on closed and open | Sensor detected the movement of autodoor, vibration of movement | 1.Adjust angle 2.Check the position 3.Adjust sensitivity |
Door do not close Red indicator lose failure | 1.Switch of autodoor controller lose failure 2.Incorrect position 3.Incorrect output sensor | Check the switch of autodoor controller &setting of output |
Door keeps on moving when it rains | Sensor detected the actins of rain | Adopt waterproof accessories |
Parameters
Technology: Microwaveµwave disposer
Transmitting power:<20dBm EIRP
Installation height: 4M(MAX)
Power:<2W(VA)
Maximum voltage: 42V AC-60V DC
Maximum switch power: 30W(DC)/60VA(AC)
Guide line:2.5M
Protection class: IP54
Color: Black/silvery
Anti-interference performance: R&tte 1995/5/EC, EMC 89/366/EEC
Power Voltage: 12V TO 30V AC+/-10%(50Hz to 60Hz): 12V TO 36V DC
Size: 120mm(W)×80mm(H)×50mm(D)
Frequency: 24,125GHz
Launch frequency density:<5mW/cm²
Installation angle: 0-90 degree(lengthways)-30 to+30(lateral)
Min detection speed: 5cm/s
Detection range: 8m*4m(installation height 2.2M)
Maximum current:1A
Retention time: 0.5s
Working temperature: -20ºC to +55ºC
Sheating material: ABS plastic